  • Vita Spa U -1 3 0 - page 1

    Manuf actur ed by DM Industries, Ltd . TM Delux e U- 130 ...

  • Vita Spa U -1 3 0 - page 2

    T ABLE OF CONTENTS Owner ’ s Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Impor tant Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Vita Spa U -1 3 0 - page 3

    This OWNER’S MANU AL has been designed to familiarize you with y our Spa operations and general maintenance . W e suggest that you take some time to carefully review it. Please keep this manual available f or reference . If you hav e any questions regarding your spa set-up , operation or mainte- nance , please contact DM T echnical Suppor t at th ...

  • Vita Spa U -1 3 0 - page 4

    —2 — IMPOR T ANT S AFETY INS TRUC TIONS WHEN INS T ALLING AND USING THIS ELEC TRIC AL EQUIPMENT , B ASIC S AFETY PREC A UTIONS SHOULD AL W A Y S BE FOLLO WED , INCLUDING THE FOLLO WING: 1. W ARNING : T o reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times. 2. DANGER! RISK OF AC CI ...

  • Vita Spa U -1 3 0 - page 5

    DO’S & DON’TS DO Make sure the spa is connected to a Ground F ault Circuit Interrupter (GFCI) protected circuit. This GFCI is required by the National Electrical Code (NEC) and is supplied with the unit. DO T est the water with your hand before ent ering the spa to be sure it is comfortable. DO Remember that wet sur faces can be slippery . ...

  • Vita Spa U -1 3 0 - page 6

    W ARNINGS Pr olonged immersion in water that is warmer than normal body temperature can r esult in a dangerous condition known as HYPO THERMIA. The causes, symptoms , and effects of hypothermia ma y be described as follows: Hypothermia occurs when the internal temperature of the body r eaches a level sev eral degrees abov e the normal body temperat ...

  • Vita Spa U -1 3 0 - page 7

    INS T ALLA TION INS TRUC TIONS Site Selection/P reparation The spa must be installed on a structurally strong , solid and reasonably level surface. The site should allow f or drainage awa y from the equipment compar tment in which the elec- trical components are housed . T ake into account the following when considering prospective sites: L OCAL CO ...

  • Vita Spa U -1 3 0 - page 8

    Spa Location 1 2 3 4 5 6 CLEARANCES CHECK THE FOLL OWING AREAS PRIOR TO SP A DELIVERY 1. STEPS - W e suggest no more than six without a landing. 2. TREE BRANCHES - Clearance for spa passage. 3. TIGHT CORNERS - Make sure there is space to maneuv er . 4. STORA GE SHEDS, DOG HOUSES, WOOD PILES - Remove out of the way . 5. GA TES: CLEARANCE FOR P ASSAG ...

  • Vita Spa U -1 3 0 - page 9

    WIRE Y OUR SP A PER ONE OF THE DIAGRAMS MOST SIMILAR TO Y OUR HOUSE P ANEL ALL WIRES FEEDING THE SP A ARE T O BE THE SAME GA UGE. GROUND WIRES ARE T O BE INSULA TED AS WELL. WHEN USING A GROUND ROD , THE GROUND WIRE T O THE ROD SHOULD BE #6 BARE C OPPER. ALL SP AS REQUIRE THE USE OF AN ISOLA TED GFCI PRO TECTED CIRCUIT . THE INST ALLA TION OF A DIS ...

  • Vita Spa U -1 3 0 - page 10

    C OMMON NEUTRAL GROUND BAR IN MAIN SEP AR A TE NEUTRAL & WEAK GROUND OR ROMEX WIRE USED TO FEED GFCI WITH UNDERSIZED GROUND WIRE —8 — ...

  • Vita Spa U -1 3 0 - page 11

    GFCI IN P ANEL WITH SEP AR A TE NEUTRAL AND SOLID GROUND T O P ANEL GFCI IN P ANEL WITH C OMMON NEUTRAL BAR AND/OR ROMEX WITH UNDERSIZED WIRE USED T O FEED DIS- C ONNECT . —9 — ...

  • Vita Spa U -1 3 0 - page 12

    GFCI MOUNTED IN P ANEL AND DISC ONNECT MOUNTED INSIDE T O C OMMON W ALL WITH MET AL STUDS OR WITH MET AL MOUNTING BO X. GFCI IN P ANEL WITH WEAK GROUND OR ROMEX WITH UNDER- SIZED GROUND WIRE USED T O FEED DISC ONNECT — 10 — ...

  • Vita Spa U -1 3 0 - page 13

    1. T he spa must be permanently con- nected (hardwired) to the power sup- ply . No extension cords or plug-type connections are to be used in con- junction with the operation of the spa. F ailure to supply pow er to the spa that is not in accordance with these instructions could create a potential health hazard and will v oid both the manufacturer ...

  • Vita Spa U -1 3 0 - page 14

    Getting Started: NO TE: F or best results, read each step carefully and en tirely before proceeding t o the nex t. FILL Y OUR SP A Wipe the interior of the spa with a damp , soft cloth to remov e any residue that may be on the sur face . F ill with a garden hose. As the spa is filling check in the equipment access area for an y leaks. On occasion, ...

  • Vita Spa U -1 3 0 - page 15

    CONTROLS & OPERA TING INS TRUC TIONS Note: For best results , read each step carefully and entirely bef ore proceeding to the next. TESTING THE GFCI The GFCI shuts off the electricity in a frac tion of a second if there is ashort anywhere in the system. It is rec- ommended that the GFCI be tested prior to each use . T est as follows: 1. Push th ...

  • Vita Spa U -1 3 0 - page 16

    D . Auto Heat Operation This equipment has includes a 2-speed pump for the primary pump. The low speed operates during filtr a- tion and heating cycles. Y our selec ted water temper ature will be maintained automatically 24 hours a day . The electronic thermostat will monitor your water t emperature at the top of each hour by cycling the low speed ...

  • Vita Spa U -1 3 0 - page 17

    J. Resetting Y our Spa Just like your computer at home , you spa electronics could get corrupted by electrical surges or spikes, or by low voltage . This could result in improper operation. Anytime there is reason to believe that y our system is not operating properly , please follow the f ollowing resetting procedur e: 1. T urn the power to the of ...

  • Vita Spa U -1 3 0 - page 18

    SP A MAINTENANCE Y our spa is manufactured with the highest quality and most durable materials available . A spa care and maintenance progr am is recommended to increase your comfort, main- tain the spa ’ s reliability and protec t your in vestment. 1) DRAINING Y OUR SP A Detergent residues from bathing suits as w ell as soap film from your body ...

  • Vita Spa U -1 3 0 - page 19

    3) FIL TER MAINTENANCE Maintenance is the most critical factor in keeping your spa water clean. T o clean the filter: NEVER RUN SP A WITHOUT FIL TER A. Remove the cartridge and spray it with a garden hose. It will be necessar y to rotate the car tridge while spra ying so as to thoroughly remove the debris lodged betw een the filter pleats. B. After ...

  • Vita Spa U -1 3 0 - page 20

    W A TER QU ALITY AND MAINTENANCE GENERAL GUIDELINES FOR W A TER QU ALIT Y MAINTENANCE Maintaining water quality within specific limits will enhance your enjoyment and prolong the life of the spa. Safe, comfor table and clean spa water is a fairly simple task to achiev e, but it does require regular attention because of the numer ous factors that ca ...

  • Vita Spa U -1 3 0 - page 21

    DIA GNOS TIC & TROUBLESHOOTING Resetting Y our Spa Just like your computer at home , you spa electronics could get corrupted b y elec trical surges and operate impr operly . If your spa system is not operating properly or sho ws any of the following messages , please reset it to see if the mal- function clears itself. T urn power off f or 15 fu ...

  • Vita Spa U -1 3 0 - page 22

    Maintenance Record Keep track of your water maint enance — 21 — ...

  • Vita Spa U -1 3 0 - page 23

    — 20 — Schemat ic U U 130 T erminal Block T ransformer Pressure S witch Heater Circuit Board ...

  • Vita Spa U -1 3 0 - page 24

    - 22 - LI M ITED W AR R ANT Y FOR E C O SP AS DM Industries, Ltd. 23 20 NW 1 4 7th Street, Miami, Florida 3305 4 WARR-ECO05-0117 DM Industries, Ltd., extends this limited warranty solely to the original Purchaser of any Eco Spa pur chased within the United States or Canada. 5 YEAR STRUCTUR AL SP A SHELL: DM Industries, Ltd., warrants its shells aga ...

  • Vita Spa U -1 3 0 - page 25

    © 2005 DM Industries Ltd 2320 NW 147th Street Miami, Florida 33054 PH 305-685-5739 ECODX-05-0517 ...

Produzent Vita Spa Kategorie Hot Tub

Dokumente, die wir vom Produzenten des Geräts Vita Spa U -1 3 0 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Vita Spa
- Bedienungsanleitungen U -1 3 0
- Produktkarten Vita Spa
- Informationsbroschüren
- oder Energieetiketten Vita Spa U -1 3 0
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Vita Spa U -1 3 0.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Vita Spa U -1 3 0, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Vita Spa U -1 3 0. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Vita Spa U -1 3 0 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Vita Spa U -1 3 0, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Vita Spa U -1 3 0 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Vita Spa U -1 3 0 verständlich ist.

Eine gänzliche Bedienungsanleitung von Vita Spa sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Vita Spa U -1 3 0 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Vita Spa U -1 3 0 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Vita Spa U -1 3 0, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Vita Spa U -1 3 0 - die uns die ersten Schritte während der Nutzung von Vita Spa U -1 3 0 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Vita Spa U -1 3 0 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Vita Spa U -1 3 0 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Vita Spa U -1 3 0?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Vita Spa U -1 3 0 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Vita Spa U -1 3 0 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)