Bedienungsanleitung Emerson CF452AP00

12 Seiten 0.26 mb
Download

Zur Seite of 12

Summary
  • Emerson CF452AP00 - page 1

    Part No. F40BP73980001 Form No. BP7398-1 U.L. Model No.: CF452 READ AND SA VE THESE INSTRUCTIONS 52” Ceiling F an Owner's Manual CF452AW00 - Summer W hite CF452AP00 - Antique P ewter CF452BS00 - Br ushed Steel CF452GBZ00 - Gilded Br onze CF452GES00 - Golden Espr esso CF452ORB00 - Oil R ubbed Br onze Model Number s CARRERA BELLA ™ Net W eig ...

  • Emerson CF452AP00 - page 2

    WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. ...

  • Emerson CF452AP00 - page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. One ceiling cover d. Five blade flanges e. One hanger ball/4.5” downrod assembly f. One hanger bracket g. One coupling cover h. Five fan blades i. ...

  • Emerson CF452AP00 - page 4

    2. Mount blade flanges to fan blades using three M5 x 6mm washer head blade screws (Figure 2). NOTE: Take care not to scratch fan housing when installing blades. 4 1. Rotate the motor hub to align the hub motor area over each of the five shipping retainers. One by one unscrew each of the five screws and discard screws and shipping retainers (Figure ...

  • Emerson CF452AP00 - page 5

    SWITCH HOUSING MOUNTING SCREW (3) SWITCH HOUSING ASSEMBL Y MOTOR CONNECTOR SWITCH HOUSING CONNECTOR 5 Figure 4 4. The blade flanges have an interlocking feature that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on th ...

  • Emerson CF452AP00 - page 6

    CEILING COVER HANGER BALL PIN SETSCREW Figure 9 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. WARNING ! 12. The fan comes with blue, black and white leads that are 80” long. Before install ...

  • Emerson CF452AP00 - page 7

    7 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 10). A T LEAST 7' CEILING FLOOR Figure 10 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. WARNING ! ...

  • Emerson CF452AP00 - page 8

    8 U.L. Model No.: CF452 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green c ...

  • Emerson CF452AP00 - page 9

    1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direction, turn your fan ...

  • Emerson CF452AP00 - page 10

    10 WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, 2. Check line wire ...

  • Emerson CF452AP00 - page 11

    11 20 6 5 9 13 12 19 16 10 14 17 18 21 7 8 11 1 2 3 15 4 U.L. Model No.: CF452 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-8 ...

  • Emerson CF452AP00 - page 12

    U.L. Model No.: CF452 Part No. F40BP73980001 Printed in China 07/09 Form No. BP7398-1 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in w ...

Produzent Emerson Kategorie Fan

Dokumente, die wir vom Produzenten des Geräts Emerson CF452AP00 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen CF452AP00
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson CF452AP00
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson CF452AP00.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson CF452AP00, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson CF452AP00. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson CF452AP00 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson CF452AP00, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson CF452AP00 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson CF452AP00 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson CF452AP00 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson CF452AP00 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson CF452AP00, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson CF452AP00 - die uns die ersten Schritte während der Nutzung von Emerson CF452AP00 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson CF452AP00 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson CF452AP00 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson CF452AP00?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson CF452AP00 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson CF452AP00 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)