Bedienungsanleitung Campbell Manufacturing DB1

18 Seiten 0.8 mb
Download

Zur Seite of 18

Summary
  • Campbell Manufacturing DB1 - page 1

    DB1 Liquid Level Measurement Sensor Revision: 12/07 Copyright © 1993-2007 Campbell Scientific, Inc. ...

  • Campbell Manufacturing DB1 - page 2

    Warranty and Assistance The DB1 LIQUID LEVEL MEASUREMENT SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in m aterials and workmanship under norm al use and service for twelve (12) m onths from date of shipment unl ess specified otherwise. Bat teries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this w ...

  • Campbell Manufacturing DB1 - page 3

    DB1 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Overview ....................................................................... 1 2. Specifications .............................................................. 2 3. In ...

  • Campbell Manufacturing DB1 - page 4

    This is a blank page. ...

  • Campbell Manufacturing DB1 - page 5

    DB1 Liquid Level Measurement Sensor 1. Overview The double bubbler is a self-cali brating system for l iquid level m easurement. This manual focuses on water level measurement in stilling wells o r open channels, but the inform ation applies to other l iquids as well. The system detects water level by measuring the pressure required t o force a nit ...

  • Campbell Manufacturing DB1 - page 6

    DB1 Liquid Level Measurement Sensor 2. Specifications Measurement Range: Option - 5 (0 to 5 psi/0 to 11.5 ft.) Option - 15 (0 to 15 psi/0 to 34.5 ft.) Option - 30 (0 to 30 psi/0 to 69 ft .) Maximum Overpressure Range: Option - 5 20 psi Option - 10 45 psi Option - 15 60 psi Transducer Accuracy: ± 0.05 % Full Scale Temperature Range: -25 ° to + 50 ...

  • Campbell Manufacturing DB1 - page 7

    DB1 Liquid Level Measurement Sensor fluctuates between 5 and 15 ft (2.2 a nd 6.5 psi ), set the pressure regulator above 7 psi (read 10 psi) to ensure adequate pressure. Open the nitrogen bottle valve, set the p ressure regulator, an d adjust the nitrogen flow by adjusting t he two needle valves. The suggested bubble rate is 1 to 3 bubbles/seconds. ...

  • Campbell Manufacturing DB1 - page 8

    DB1 Liquid Level Measurement Sensor FIGURES 1 and 2. The DB1 System 4 ...

  • Campbell Manufacturing DB1 - page 9

    DB1 Liquid Level Measurement Sensor CR10(X) , CR1000, CR 800 CR850, 21X FIGURE 3. Wiring Diagram for DB1 5 ...

  • Campbell Manufacturing DB1 - page 10

    DB1 Liquid Level Measurement Sensor 5. Programming Every 60 seconds, the following program examples calcul ate the pressure transducer multiplier, measure the offset, and measure the liquid level. The average liquid level i s stored in final m emory every 15 m inutes. 5.1 CR1000 Example 'CRBasic code for CR1000, CR800, or C R850 Public WtrLvl ...

  • Campbell Manufacturing DB1 - page 11

    DB1 Liquid Level Measurement Sensor C a s e 3 P o r t S e t ( 3 , 1 ) 'Open valve to atmosphere EndSelect Delay(0,150,MSEC) S u m = 0 For j = 1 To 25 'Take 25 pressure readings for each tube and atmosphere BrFull(m V, 1, mV25,4, VX1, 1, 2500, true, true, 0, _60Hz, 1, 0) Su m = Su m + mV N e x t j Valve(i)= Sum/25 'Average the 25 read ...

  • Campbell Manufacturing DB1 - page 12

    DB1 Liquid Level Measurement Sensor 3: Excitation with Delay (P22 ) 1: 1 EX Chan 2: 0 Delay w/EX (units=.01sec) 3: 150 Delay after EX (unit s=.01sec) 4: 0 mV Excit ation Subroutine 1 measures the pressure in the tubing connected t o the second value: 4: Do (P86) 1: 1 Call Subrouti ne 1 5: Do (P86) 1: 52 Set low Port 2 The following instruct ions co ...

  • Campbell Manufacturing DB1 - page 13

    DB1 Liquid Level Measurement Sensor 2: Z=F (P30) 1: 0 F 2: 0 Exponent of 10 3: 7 Z Loc [:SUM ] 3: Beginning of Loop (P87) 1: 0 Delay 2: 25 Loop Count 4: Full Bridge (P6) 1: 1 Rep 2: 23 25 mV 60 Hz reject ion Range 3: 1 IN Chan 4: 1 Excite all reps w/EXchan 1 5: 2500 mV Excitation 6: 6 Loc [:mV/V ] 7: 1 Mult 8: 0 Offset 5: Z=X+Y (P33) 1: 7 X Loc SUM ...

  • Campbell Manufacturing DB1 - page 14

    DB1 Liquid Level Measurement Sensor 13: Do (P86) 1: 1 Call Subrouti ne 1 14: Z=X (P31) 1: 8 X Loc AVG LEVEL 2: 9-- Z Loc [:m V/V #1 ] 15: Do (P86) 1: 51-- Set low Port 1 16: End (P95) 17: Z=X-Y (P35) 1: 10 X Loc mV/ V #2 2: 9 Y Loc mV/V #1 3: 12 Z Loc [:DELTA V ] Note: On the next command, enter the measured Del ta h value for F, using the units (e ...

  • Campbell Manufacturing DB1 - page 15

    DB1 Liquid Level Measurement Sensor 6.1 Periodic Maintenance • Inspect submerged bubbler t ubes for sediment or ot her debris. Remove debris and clean tubes as required. • Replace submerged bubbler tubes if cracked or dama ged. • Replace nitrogen bottle every 2 to 3 months dependi ng on bubble rate. • Inspect valves for leaks every 2 to 3 m ...

  • Campbell Manufacturing DB1 - page 16

    DB1 Liquid Level Measurement Sensor 12 7. Replacement Parts Part # Description Qty. in DB1 5199 SWAK THREAD SEALANT 1 7397 TUBE FITTING ELL 1/4 O.D.x 1/8NPT 4 7558 NEEDLE VALVE ASSEMBLY 2 7561 2-WAY NC SOLENOID VALVE 3 7571 PLUG PIPE 1/8NPT TEFCOAT 2 6078 MOUNTING SCREW (6/32 x 2.00in) 4 7596 DB1 MANIFOLD BLOCK 1 7680 TUBE CUTTER 1 7667 RELAY CABLE ...

  • Campbell Manufacturing DB1 - page 17

    This is a bl ank page . ...

  • Campbell Manufacturing DB1 - page 18

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Aust ralia Pty. Ltd. (CSA) PO Box 444 Thu ...

Produzent Campbell Manufacturing Kategorie Stud Sensor

Dokumente, die wir vom Produzenten des Geräts Campbell Manufacturing DB1 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Campbell Manufacturing
- Bedienungsanleitungen DB1
- Produktkarten Campbell Manufacturing
- Informationsbroschüren
- oder Energieetiketten Campbell Manufacturing DB1
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Campbell Manufacturing DB1.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Campbell Manufacturing DB1, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Campbell Manufacturing DB1. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Campbell Manufacturing DB1 ansehen.

Die komplette Bedienungsanleitung des Geräts Campbell Manufacturing DB1, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Campbell Manufacturing DB1 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Campbell Manufacturing DB1 verständlich ist.

Eine gänzliche Bedienungsanleitung von Campbell Manufacturing sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Campbell Manufacturing DB1 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Campbell Manufacturing DB1 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Campbell Manufacturing DB1, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Campbell Manufacturing DB1 - die uns die ersten Schritte während der Nutzung von Campbell Manufacturing DB1 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Campbell Manufacturing DB1 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Campbell Manufacturing DB1 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Campbell Manufacturing DB1?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Campbell Manufacturing DB1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Campbell Manufacturing DB1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)