    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance . • Do not touch any electrical switch ; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’ s phone . Follow the gas sup ...

  • Weil-McLain EGH - page 2

    2 Part Number 550-110-592/1000 Please read this page first How to use this manual . . . The User ’ s Infor mation Manual pro vides information to the boiler o w ner/user for r outine operation and maintenance and emergency shutdown. Detailed information on boiler installation, operation, start-up, service and parts is included in the Boiler Manua ...

  • Weil-McLain EGH - page 3

    3 Part Number 550-110-592/1000 F ailure t o adher e to the guidelines on this pag e can result in sev ere personal injury , death or substantial property damage. STOP!! — Read before proceeding Products to avoid Spray cans containing chloro/fluorocar- bons Permanent wave solutions Chlorinated waxes/cleaners Chlorine-based swimming pool chemicals ...

  • Weil-McLain EGH - page 4

    4 Part Number 550-110-592/1000 5921 0 Boiler components 5921 1 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 6 Inducer (CGi and CGs only) 7 V ent damper (CGa only) 8 W ater temperature limit switch 9 T ransformer 10 Spill switc h (CGa only) 11 Air pressure switc h (CGi and CGs only) 12 Rollout thermal fuse elemen ...

  • Weil-McLain EGH - page 5

    5 Part Number 550-110-592/1000 ▲ ▲ 59215 (PFG-5 only) (PFG-5 only) ▲ ▲ Not shown ▲ 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 7 V ent damper 9 T ransformer 10 Spill switc h 12 Rollout thermal fuse element 13 Low water cutoff (steam boilers) 14 Limit control(s) 15 Draft hood 16 Circulator 18 Gauge (pr ...

  • Weil-McLain EGH - page 6

    6 Part Number 550-110-592/1000 Maintain boiler using schedule below T ankless water heater (EG and EGH only) If boiler is used to supply d omestic hot water , limit co ntrol should be set to suppl y adequate hot water . W eil-M cLain tankless heaters are rated at 200 ° F boile r water t emperature. T o ge t rated output, set low limit at 200 ° F ...

  • Weil-McLain EGH - page 7

    7 Part Number 550-110-592/1000 User maintenance procedures Do not attempt to place boiler in operation if spill switch cuts of f gas flow . Immediately call a serv ice technician. Failure to do so can cause severe personal injury , death or substantial pr oper t y damage. Rollout thermal fuse element CGa, CGi, CGs, EG, EGH, PEG & PFG-5 only Cu ...

  • Weil-McLain EGH - page 8

    8 Part Number 550-110-592/1000 ❏ Check daily . . . . . . . . . . . . . . . . . Air openings 1 . V er ify that combustion and v entilation air openings to the boiler room and/or building are open and unobstructed. 2. CGs boilers — V erify that b oiler vent disc harge and air intake are clean and free of obstructions. Remove any debris on the air ...

  • Weil-McLain EGH - page 9

    9 Part Number 550-110-592/1000 Figure 4 Automatic air vent Automatic air vents (if used) 1 . See Figure 4 . 2 . Remove the cap from any automatic air vent in the system and check operation by depressing valve B slightly with the tip of a screwdriv er . 3. If the air vent valve appears to be working freely and not leaking , replace cap A , twisting ...

  • Weil-McLain EGH - page 10

    10 Part Number 550-110-592/1000 Probe type— See Figure 8 1 . Clean probe type low water cutoff for proper operation. a. T urn off power to boile r and wait 5 minutes. b . Drain water to bottom of gauge glass. c. T urn o n pow er . d. Set thermostat to call for heat. Red neon lamp on lower water cutoff should light. e. W ait 5 minutes. Boile r sho ...

  • Weil-McLain EGH - page 11

    11 Part Number 550-110-592/1000 Operate boiler relief valve ❏ Service every 6 months . . . . . . . . . To av oid water damage or scalding due to valve operation, a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal. This discharge line must be installed by a qualified heating installer or service tec ...

  • Weil-McLain EGH - page 12

    12 Part Number 550-110-592/1000 Follow boiler shutdown procedure ❏ End-of-season shutdown . . . . . . . . 1. Follo w “ TO TURN OFF GA S T O APPLIANCE ” on the Lighting/Operating instr uctions on the inside of the jacket panel. Y ou will also find these instructions on pages 13 through 22 of this manual. U se the Lighting/Operating instr uctio ...

  • Weil-McLain EGH - page 13

    13 Part Number 550-110-592/1000 Lighting instructions FOR Y OUR S AFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the g ...

  • Weil-McLain EGH - page 14

    14 Part Number 550-110-592/1000 • Gas valve — Robertshaw 7200 FOR Y OUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. F ...

  • Weil-McLain EGH - page 15

    15 Part Number 550-110-592/1000 FOR Y OUR S AFETY READ BEFORE LIGHTING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s i ...

  • Weil-McLain EGH - page 16

    16 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain EGH - page 17

    17 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain EGH - page 18

    18 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain EGH - page 19

    19 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain EGH - page 20

    20 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE LIGHTING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s i ...

  • Weil-McLain EGH - page 21

    21 Part Number 550-110-592/1000 FOR YOUR SAFETY READ BEFORE OPERA TING OPERA TING INSTRUCTIONS TO TURN OFF GAS TO THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instru ...

  • Weil-McLain EGH - page 22

    22 Part Number 550-110-592/1000 ANNUAL SHUTDOWN PROCEDURE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach y our gas supplier , call the fire dep ...

  • Weil-McLain EGH - page 23

    23 Part Number 550-110-592/1000 Common problems and solutions Symptom Common Causes Possible Corrections Rapid cycling — boiler turns on and off frequently Thermostat installed where drafts or heat affect reading Locate thermostat on inner wall away from heat sources or cool drafts. Heat anticipator in thermostat adjusted incorrectly Adjust therm ...

  • Weil-McLain EGH - page 24

    24 Part No. 550-110-592/1000 W eil-McLain Limited W arranty for Residential & Commercial Cast Iron Boilers W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com RESIDENTIAL W A TER W ARRANTY—Limited Lifetime RESIDENTIAL STEAM W ARRANTY—Limited 10 Y ear COMMERCIAL W ARRANTY—Limited 10-Y ear NOTE: The resi ...

Produzent Weil-McLain Kategorie Boiler

Dokumente, die wir vom Produzenten des Geräts Weil-McLain EGH erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Weil-McLain
- Bedienungsanleitungen EGH
- Produktkarten Weil-McLain
- Informationsbroschüren
- oder Energieetiketten Weil-McLain EGH
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Weil-McLain EGH.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Weil-McLain EGH, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Weil-McLain EGH. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Weil-McLain EGH ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Weil-McLain EGH, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Weil-McLain EGH hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Weil-McLain EGH verständlich ist.

Eine gänzliche Bedienungsanleitung von Weil-McLain sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Weil-McLain EGH bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Weil-McLain EGH befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Weil-McLain EGH, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Weil-McLain EGH - die uns die ersten Schritte während der Nutzung von Weil-McLain EGH erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Weil-McLain EGH hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Weil-McLain EGH im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Weil-McLain EGH?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Weil-McLain EGH nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Weil-McLain EGH hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)