Bedienungsanleitung Emerson 20002514

14 Seiten 0.97 mb
Download

Zur Seite of 14

Summary
  • Emerson 20002514 - page 1

    Installation Manual 20002514, Rev BA December 2010 Micro Motion ® R-Series Coriolis Flow Sensors ...

  • Emerson 20002514 - page 2

    Safety and approval information This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the ...

  • Emerson 20002514 - page 3

    Contents Chapter 1 Planning ...........................................................................................................................1 1.1 Installation checklist ........................................................................................................................1 1.2 Best practices ............................. ...

  • Emerson 20002514 - page 4

    Contents ii Micro Motion R-Series ...

  • Emerson 20002514 - page 5

    1 Planning Topics covered in this chapter: • Installation checklist • Best practices • Environmental limits 1.1 Installation checklist □ Make sure that the hazardous area specified on the sensor approval tag is suitable for the environment in which the sensor is installed. □ Verify that the local ambient and process temperatures are withi ...

  • Emerson 20002514 - page 6

    Recommended sensor orientation Table 1-3: Liquids Gases Slurries □ Install the sensor so that the flow direction arrow on the sensor matches the actual forward flow of the process. 1.2 Best practices The following information can help you get the most from your sensor. • There are no pipe run requirements for Micro Motion sensors. Straight runs ...

  • Emerson 20002514 - page 7

    Environmental limits for R-Series sensors Figure 1-1: Maximum process temperature in °F (°C) 176 (80) 140 (60) 104 (40) 68 (20) 32 (0) –4 (–20) –40 (–40) –148 (–100) 158 (70) Ambient temperature of core processor or transmitter in °F (°C) –112 (–80) –76 (–60) –40 (–40) –4 (–20) 32 (0) 68 (20) 104 (40) 140 (60) 176 (8 ...

  • Emerson 20002514 - page 8

    2 Mounting 2.1 Mount the sensor Use your common practices to minimize torque and bending load on process connections. Tip To reduce the risk of condensation or excessive moisture, the conduit opening should not point upward (if possible). The conduit opening of the core processor can be rotated freely to facilitate wiring. Procedure Mount the senso ...

  • Emerson 20002514 - page 9

    3 Wiring Topics covered in this chapter: • Options for wiring • Connect 4-wire cable 3.1 Options for wiring The wiring procedure you follow depends on which electronics option you have. See Table 3-1 for the wiring options for each sensor electronics option. Wiring procedures by electronics option Table 3-1: Electronics option Wiring procedure ...

  • Emerson 20002514 - page 10

    Step 1: Cable preparation Cable layout Run conduit to sensor Metal conduit Wrap the drain wires twice around the shield and cut off the excess drain wires. Micro Motion cable gland Pass the wires through the gland Cable glands Remove the core processor cover Go to Step 2 Go to Step 3 Gland supplier User-supplied cable gland Lay cable in conduit Dra ...

  • Emerson 20002514 - page 11

    Step 2: Shield termination Assemble the Gland 1. Fold the shield or braid back over the clamping insert and 1/8 inch (3 mm) past the O-ring. 2. Install the gland body into the conduit opening on the core processor housing. 3. Insert the wires through gland body and tighten the gland nut onto the gland body. Apply the Heat Shrink 1. Slide the shield ...

  • Emerson 20002514 - page 12

    Step 3: Terminal connections Connect the wires to the transmitter terminals (see the transmitter manual) Reinstall and tighten the core processor cover From Step 1 or 2 Connect the wires to the core processor terminals: Red wire > Terminal 1 (Power supply +) Black wire > Terminal 2 (Power supply –) White wire > Terminal 3 (RS-485/A) Gree ...

  • Emerson 20002514 - page 13

    4 Grounding The sensor must be grounded according to the standards that are applicable at the site. The customer is responsible for knowing and complying with all applicable standards. Prerequisites Micro Motion suggests the following guides for grounding practices: • In Europe, IEC 79-14 is applicable to most installations, in particular Section ...

  • Emerson 20002514 - page 14

    *20002514* 20002514 Rev BA 2010 Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado 80301 T +1 303-527-5200 T +1 800-522-6277 F +1 303-530-8459 www.micromotion.com Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 www.micromotion.nl M ...

Produzent Emerson Kategorie Stud Sensor

Dokumente, die wir vom Produzenten des Geräts Emerson 20002514 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen 20002514
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson 20002514
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson 20002514.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson 20002514, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson 20002514. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson 20002514 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson 20002514, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson 20002514 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson 20002514 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson 20002514 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson 20002514 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson 20002514, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson 20002514 - die uns die ersten Schritte während der Nutzung von Emerson 20002514 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson 20002514 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson 20002514 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson 20002514?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson 20002514 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson 20002514 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)