    Part No. F40BP72680001 Form No. BP7268-1 READ AND SA VE THESE INSTRUCTIONS WINDJAMMER ™ ® Net Weight: 27.6 Lbs. Ceiling Fan Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must b ...

  • Emerson CF960WB 00 - page 2

    2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2 . Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on ...

  • Emerson CF960WB 00 - page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One light fixture assembly c. Six fan blades d. Six blade flanges e. One ceiling cover f. One hanger ball/downrod assembly g. One hanger bracket h. One coupling cover i. One light ...

  • Emerson CF960WB 00 - page 4

    5. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 4). 6. Reinstall the hanger ball (Figure 5) on the downrod as foll ...

  • Emerson CF960WB 00 - page 5

    7. The fan comes with blue, black and white leads that are 80” long. Before installing the fan, measure up approximately 6 to 9-inches above the top of hanger the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from the end of leads. 8. Your new ceiling fan will require a grounded 120 volts AC, 60 Hz, 15 amp electri ...

  • Emerson CF960WB 00 - page 6

    3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 9). 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 10). 5. Secure the ceiling cover in place by sliding #8 lockwashers over the threaded studs and installing the two knurled ...

  • Emerson CF960WB 00 - page 7

    7 To avoid possible fire or shock, make sure that the electrical wires are not pinched between the light fixture assembly and the mounting plate. W ARNING ! 3. Partially install two 3/16-24 x 1/4” Phillips round head screws in two of the tapped holes in the coupling adapter (Figure 13). Leave two or three threads untightened. 4. Position the keyh ...

  • Emerson CF960WB 00 - page 8

    8 Installation of Light Adapter Plate NOTE: In order to use the light adapter plate (supplied), the wiring harness included as part of the light fixture assembly must be removed and be reinstalled in the light adapter plate. This Section contains the procedures to accomplish this. 1. Disconnect the light fixture connector from the wiring harness co ...

  • Emerson CF960WB 00 - page 9

    9 Using Y our Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the speed control pull chain switch (Figure 23). The operating sequence is as follows: THREE-SPEED 1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low 4th Pull—OFF 3. If ai ...

  • Emerson CF960WB 00 - page 10

    10 WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan. 2. Check line wir ...

  • Emerson CF960WB 00 - page 11

    13 26 27 14 28 16 17 15 24 20 9 19 18 3 1 5 4 6 7 8 2 21 25 23 22 12 11 10 11 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-80 ...

  • Emerson CF960WB 00 - page 12

    Part No. F40BP72680001 Printed in Taiwan 05/03 Form No. BP7268-1 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W. Florissant ¥ St. Louis, MO 63136 Repair Par ts Listing Model No. Key N o . Description CF960CK00 CF960WB00 CF960BS00 * Hanger Ball Assembly , 761655-23 761655-20 761655-17 Consisting of: 1 Hanger Bracket — — — 2 Hanger Ba ...

Produzent Emerson Kategorie Fan

Dokumente, die wir vom Produzenten des Geräts Emerson CF960WB 00 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen CF960WB 00
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson CF960WB 00
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson CF960WB 00.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson CF960WB 00, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson CF960WB 00. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson CF960WB 00 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson CF960WB 00, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson CF960WB 00 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson CF960WB 00 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson CF960WB 00 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson CF960WB 00 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson CF960WB 00, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson CF960WB 00 - die uns die ersten Schritte während der Nutzung von Emerson CF960WB 00 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson CF960WB 00 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson CF960WB 00 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson CF960WB 00?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson CF960WB 00 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson CF960WB 00 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)