    1 • Inst allation • Operation • Maintenance • Checklist • Limited Warranty CAUTION TEXT PRINTED OR OUTLINED IN RED CONT AINS INFORMA TION RELA TIVE TO YOUR SAFETY . PLEASE READ THOROUGHL Y BEFORE INST ALLING AND USING THIS APPLIANCE. KEEP THIS MANUAL WITH THE HEA TER FOR FUTURE REFERENCE. WHENEVER MAINTENANCE ADJUSTMENTS OR SERVICE IS REQ ...

  • State Industries SSE-120 - page 2

    2 RECOVER Y CAP ACITY DIMENSIONS RECOVERY RA TE IN GALLONS PER HOUR * T emperature Rise F° (C°) T ank Cap acity Maximum All Dimensions in Inches (mm) Approx. Ship in Gals.(Ltrs) KW Input A B C D Wt.Lbs.(Kgs) 5 1 9 3 2 0 1 / 2 521mm 1 6 1 / 4 413 mm 21 1/2 546 mm 5 1/4 133 mm 82 37.2 10 3 8 6 26 1/4 667 mm 18 3/4 476 mm 24 610 mm 5 1/4 133 mm 106 ...

  • State Industries SSE-120 - page 3

    3 T ABLE OF CONTENTS P AGE ROUGH-IN-DIMENSIONS ...................................... 2 RECOVERY CAP ACITY ....................................... 2 F O R E W O R D ......................................................... 3 T ABLE OF CONTENTS ......................................... 3 APPROV ALS & MODEL & RA TING PLA TE .......... 3 GETTI ...

  • State Industries SSE-120 - page 4

    4 GETTING TO KNOW YOUR W A TER HEA TER Below is an illustration of the water heater with its features called out. The text of this manual will refer to the items shown. FIGURE 1 NOTE: • 3/4” NPT SSE 5 THRU 50 MODELS • 1 1/4” NPT SSE 65 THRU 120 MODELS • A LOW W A TER CUTOFF SWITCH IS A V AILABLE AS AN OPTIONAL SAFETY DEVICE TO PROTECT THE ...

  • State Industries SSE-120 - page 5

    5 GENERAL SAFETY INFORMA TION INSULA TION BLANKETS Insulation blankets available to the general public for external use on electric water heaters are not approved for use on your S tate water heater . The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank water heaters. Y our St ate water heater meets ...

  • State Industries SSE-120 - page 6

    6 RELIEF DEVICES An unplugged 3/4” NPT relief valve opening is provided for installing temperature and pressure relief valve. CAUTION: TO REDUCE THE RISK OF EXCESSIVE PRESSURES AND TEMPERA TURE IN THIS WA TER HEA TER INST ALL TEMPERA TURE AND PRESSURE PROTECTIVE EQUIPMENT REQUIRED BY LOCAL CODES but not less than a combination temperature and pre ...

  • State Industries SSE-120 - page 7

    7 PIPING DIAGRAM ONE OR TWO TEMPERA TURE - ONE HEA TER ONE OR TWO TEMPERA TURE - TWO HEA TER DANGER : TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL W ARNING ON P AGES 17 & 18. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSARY TO OBT AIN ADEQUA TE BOOSTER OUTPUT , ADD AN ANTI-SCALD V A L ...

  • State Industries SSE-120 - page 8

    8 ONE OR TWO TEMPERA TURE - THREE HEA TERS ONE OR TWO TEMPERA TURE - FOUR HEA TERS CAUTION: IF BUILDING COLD W A TER SUPPL Y HAS A BACK-FLOW PREVENTER, CHECK V AL VE OR W A TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF W A TER IN THE HOT W A TER SYSTEM MUST BE PROVIDED. *PIPE TO OPEN DRAIN. INST ALL IN ACCORDANCE WITH ALL LOCAL ...

  • State Industries SSE-120 - page 9

    9 MEDIUM TEMPERA TURE - ONE HEA TER VERTICAL ST ORAGE T ANK MEDIUM TEMPERA TURE - ONE HEA TER HORIZONT AL STORAGE T ANK *PIPE RELIEF V AL VE TO OPEN DRAIN. †T ANK TEMPERA TURE CONTROL SET A T DESIRED TEMPERA TURE - MAX. 170°F (76.6 mm). HEA TER THERMOST A T SET A T LEAST 5° HIGHER. INST ALL IN ACCORDANCE WITH AL L LOCAL CODES. CAUTION: IF BUILD ...

  • State Industries SSE-120 - page 10

    10 MEDIUM TEMPERA TURE - TWO HEA TERS HORIZONT AL STORAGE T ANK MEDIUM TEMPERA TURE - TWO HEA TERS VERTICAL STORAGE T ANK RETURN LINE FROM FIXTURE CIRCULA TING LOOP (IF USED) SHOULD CONNECT TO ANY OPENING NEAR BOTTOM OF T ANK. * PIPE RELIEF V AL VE TO OPEN DRAIN. † T ANK TEMPERA TURE CONTROL SET A T DESIRED TEMPERA TURE - MAX. 170°F ( 76.6°C). ...

  • State Industries SSE-120 - page 11

    11 MEDIUM TEMPERA TURE - THREE HEA TERS HORIZONT AL ST ORAGE T ANK MEDIUM TEMPERA TURE - THREE HEA TERS VERTICAL ST ORAGE T ANK * PIPE RELIEF V AL VE TO OPEN DRAIN † T ANK TEMPERA TURE CONTROL SET A T DESIRED TEMPERA TURE (MAX. 170°F (76.6°C). HEA TER THERMOST A T SET A T LEAST 5° HIGHER. CAUTION: IF BUILDING COLD WA TER SUPPL Y HAS A BACK-FLO ...

  • State Industries SSE-120 - page 12

    12 MEDIUM TEMPERA TURE - FOUR HEA TERS HORIZONT AL STORAGE T ANK MEDIUM TEMPERA TURE - FOUR HEA TERS VERTICAL ST ORAGE T ANK CAUTION: IF BUILDING COLD WA TER SUPPL Y HAS A BACK-FLOW PREVENTER, CHECK V AL VE OR WA TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF W A TER IN THE HOT W A TER SYSTEM MUST BE PROVIDED. * PIPE RELIEF V AL ...

  • State Industries SSE-120 - page 13

    13 60°C 75°C 85°C 90°C 60°C 75°C 85°C 90°C (140°F) (167°F) ( 185°F) (194°F) (140°F) (167°F) (185°F) (194°F) TYPES TYPES TYPES TYPES TYPES TYPES TYPES TYPES RUW, T FEPW V , MI T A, TBS RUW, T RH, RHW V , MI T A , TBS, AWG TW, UF RH,RHW SA, A VB TW, UF R U H SA, A VB RUH, SIS, =FEP , THW, SIS, AW G THW, =FEPB, THWN =RHH, M C M THWN, = ...

  • State Industries SSE-120 - page 14

    14 AMPERAGE T ABLE/OVERCURRENT PROTECTION This table provides the total connected heating element load in amperes for branch circuit conductor and over current protection sizing. Single-phase heaters are two wire circuits. Three-phase heaters are three wire circuits. In addition to the foregoing a ground conductor may be required. The rating of the ...

  • State Industries SSE-120 - page 15

    15 SMALL COMMERCIAL WIRE DIAGRAM 208-240V / 3PH SMALL COMMERCIAL WIRE DIAGRAM 208-240V / 3-1PH ...

  • State Industries SSE-120 - page 16

    16 3-1 PHASE CONVERSIONS In the case where the unit is phase convertible and it has only one contactor , jumper wires (provided) must be added according to the phase of the supply voltage. See the diagram below . For single-phase connection, jumpers A-C and B-D must be added. For three-phase connection, jumper B-C must be added. 3-1 PHASE CONT ACTO ...

  • State Industries SSE-120 - page 17

    17 SMALL COMMERCIAL WIRE DIAGRAM 300-600V / 3PH NOTES ...

  • State Industries SSE-120 - page 18

    18 DANGER THIS W A TER HEA TER IS EQUIPPED WITH AN ADJUST ABLE THERMOST A T TO CONTROL WA TER TEMPERA TURE. HOT W A TER TEMPERA TURES REQUIRED FOR AU T OMA TIC DISHW ASHER AND LAUNDRY USE CAN CAUSE SCALD BURNS RESUL TING IN SERIOUS PERSONAL INJUR Y AND/ OR DEA TH. THE TEMPERA TURE A T WHICH INJURY OCCURS V ARIES WITH THE PERSON’S AGE AND TIME OF ...

  • State Industries SSE-120 - page 19

    19 MAINTENANCE Always close the front access door after making a temperature adjustment. T urn on electricity . DRAINING The water heater must be drained if it is to be shut down and exposed to freezing temperatures. Maintenance and service procedures may also require draining the heater . 1. T urn off the electrical disconnect switch. 2. Close the ...

  • State Industries SSE-120 - page 20

    20 6. Remove the elements from the openings. • Use a twisting, pulling action to remove elements scaled beyond size of the tank openings. • Brush loose scale from elements. 7. Lime scale removal. • Place limed ends of heating elements into UN•LIME delimer and allow scale to dissolve. Do not permit delimer or water to contact heating element ...

  • State Industries SSE-120 - page 21

    21 When such a condition is encountered, local codes or inspection agency should be consulted to determine which system is acceptable in your area. These may consist of: • Installation of a second relief valve set to lower than the primary safety relief valve. • An expansion tank of suitable pressure and provision to avoid water logging. • Re ...

  • State Industries SSE-120 - page 22

    22 LEAKAGE CHECKPOINTS INSTRUCTIONS : USE THIS ILLUSTRA TION AS A GUIDE WHEN CHECKING FOR SOURCES OF WA TER LEAKAGE. YOU OR YOUR DEALER MA Y BE ABLE T O CORRECT WHA T APPEARS T O BE A PROBLEM. Water on side of the tank may be condensation due to the panel or insulation not being in place. Relief valve operation and leakage may be due to water expan ...

  • State Industries SSE-120 - page 23

    23 MODEL SSE LIMITED W ARRANTY S tate W ater Heaters, the warrantor , extends the following LIMITED W ARRANTY to the owner of this water heater: 1. THE TANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the first THREE years after ...

  • State Industries SSE-120 - page 24

    24 500 Lindahl Parkway , Ashland City , TN 37015 Phone: 800-821-2017 Fax: 800-644-9306 ww w.st ateind.com ...

Produzent State Industries Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts State Industries SSE-120 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen State Industries
- Bedienungsanleitungen SSE-120
- Produktkarten State Industries
- Informationsbroschüren
- oder Energieetiketten State Industries SSE-120
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung State Industries SSE-120.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen State Industries SSE-120, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen State Industries SSE-120. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts State Industries SSE-120 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts State Industries SSE-120, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von State Industries SSE-120 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von State Industries SSE-120 verständlich ist.

Eine gänzliche Bedienungsanleitung von State Industries sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von State Industries SSE-120 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von State Industries SSE-120 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich State Industries SSE-120, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts State Industries SSE-120 - die uns die ersten Schritte während der Nutzung von State Industries SSE-120 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit State Industries SSE-120 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von State Industries SSE-120 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich State Industries SSE-120?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit State Industries SSE-120 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit State Industries SSE-120 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)