Bedienungsanleitung Western Telematic Remote Power Boot Switch

12 Seiten 0.1 mb
Download

Zur Seite of 12

Summary
  • Western Telematic Remote Power Boot Switch - page 1

    WTI Part No.: 12651 Rev. B RPB+ Remote Power Boot Switch User's Guide 5 Sterling, Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com Table of Contents 1. Introduction ● 2. Unit Description 2.1. Front Panel ❍ 2.2. Back Panel ❍ ● 3. Installation 3.1. SetUp Switches ? ...

  • Western Telematic Remote Power Boot Switch - page 2

    A. Specifications ● B. Customer Service ● List of Figures 1. Front Panel ● 2. Back Panel ● 3. RS-232 (Control Port) Interface Schematic ● 4. RPB+ Cable Connections ● 5. The Status Screen ● 1. Introduction Network equipment sometimes "locks-up", making it impossible to communicate. The RPB+ Remote Power Boot Switch can switch ...

  • Western Telematic Remote Power Boot Switch - page 3

    Throughout this manual, typefaces and characters have been used to denote the following: COURIER FONT Indicates characters typed on the keyboard. For example, /S or /3 ON . [Bold Font] Text set in bold face and enclosed in square brackets indicates a specific key. For example, [Enter] or [Esc] . 2. Unit Description 2.1. Front Panel Figure 1: Front ...

  • Western Telematic Remote Power Boot Switch - page 4

    Switched AC Outlets (Plugs 1 - 5): For connection to up to five AC devices. Each outlet is capable of switching up to 15 Amps. The total for all five outlets must not exceed 15 Amps. 1. SetUp Switches (RATE): A bank of four DIP Switches which set the Control Port baud rate, select the Off Time duration, enable/disable the Password Option, and enabl ...

  • Western Telematic Remote Power Boot Switch - page 5

    allows the user to invoke On/Off/Boot commands, but prevents redefinition of parameters such as the Password and Power-Up Default. Switch Function Up Down 1 Control Port Baud Rate 2400 bps 9600 bps* 2 Off Time 10 sec. 5 sec.* 3 Password Function Disable Enable* 4 Read Only Mode Enable Disable* * = Factory Setting 3.2. Control Port Connection The ma ...

  • Western Telematic Remote Power Boot Switch - page 6

    string. 3.3. Power Connection The Power Switch located on the back panel must be "On" in order for the RPB+ to operate. Each time the unit is powered On, the five AC outlets will be switched On or Off, as dictated by the Power-Up Default String (see Section 4.1 ). Each outlet is capable of switching up to 15 Amps of AC power. The total fo ...

  • Western Telematic Remote Power Boot Switch - page 7

    Password: If the Password function is enabled, the unit will display a prompt. Key in the Password and press [Enter] . If the password has not yet been defined, just press [Enter] . 2. Note: The Password feature is case sensitive. ● If you forget your password, press the Default Button when the Password Prompt appears, then invoke the /P command ...

  • Western Telematic Remote Power Boot Switch - page 8

    during password definition. Default (Power-Up Default): Allows the user to define default On/Off conditions for each switched plug as described in Section 4.1 . Key in the desired Power-Up Defaults and press [Enter] . c. Echo Mode: When Echo Mode is enabled, commands sent to the RPB+ will be echoed back to your PC or terminal, allowing keyboard ent ...

  • Western Telematic Remote Power Boot Switch - page 9

    Example 1: To set default On/Off conditions as follows: ON: Plugs 1 and 5 OFF: Plugs 2, 3, and 4 The Power-Up Default String would be defined as " 10001 ". Example 2: To set default plug conditions as follows: ON: Plugs 3, 4, and 5 OFF: Plugs 1 and 2 The Power-Up Default String would be defined as " 00111 ". 5. Operation The dev ...

  • Western Telematic Remote Power Boot Switch - page 10

    Enter Parameters: To define parameters, such as the Location I.D., Power-Up Default, and Plug Labels, type /P [Enter] and refer to Section 4 , Step 4. 5. Set Plugs to Default: To set all plugs to the Power-Up Defaults, type /D [Enter] . Note that if the Default String includes missing or invalid characters, the /D command will not function. 6. Exit ...

  • Western Telematic Remote Power Boot Switch - page 11

    2 RXD Data Input 3 TXD Data Output 4 DTR Ready Output 5 GND Signal Ground 6 (NC) Not Connected 7 RTS RTS Output 8 (NC) Not Connected 9 (NC) Not Connected Coding: Asynchronous. 7-8 bits, any parity ❍ Data Rate: 2400, 9600 bps (Switch Selectable) ❍ LEDs: Power ON, Control Input, Plug On (5) ● Temperature: 0° C to 30° C (operating) ● Power: ...

  • Western Telematic Remote Power Boot Switch - page 12

    Irvine, California 92618 Toll Free (U.S. & Canada): 1-800-854-7226 Phone: 949-586-9950 Fax: 949-583-9514 EMail: service@wti.com FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and 1. This device must accept any interference re ...

Produzent Western Telematic Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Western Telematic Remote Power Boot Switch erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Western Telematic
- Bedienungsanleitungen Remote Power Boot Switch
- Produktkarten Western Telematic
- Informationsbroschüren
- oder Energieetiketten Western Telematic Remote Power Boot Switch
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Western Telematic Remote Power Boot Switch.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Western Telematic Remote Power Boot Switch, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Western Telematic Remote Power Boot Switch. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Western Telematic Remote Power Boot Switch ansehen.

Die komplette Bedienungsanleitung des Geräts Western Telematic Remote Power Boot Switch, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Western Telematic Remote Power Boot Switch hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Western Telematic Remote Power Boot Switch verständlich ist.

Eine gänzliche Bedienungsanleitung von Western Telematic sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Western Telematic Remote Power Boot Switch bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Western Telematic Remote Power Boot Switch befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Western Telematic Remote Power Boot Switch, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Western Telematic Remote Power Boot Switch - die uns die ersten Schritte während der Nutzung von Western Telematic Remote Power Boot Switch erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Western Telematic Remote Power Boot Switch hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Western Telematic Remote Power Boot Switch im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Western Telematic Remote Power Boot Switch?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Western Telematic Remote Power Boot Switch nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Western Telematic Remote Power Boot Switch hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)