    www.Fisher.com D10031 1X012 Type 6 67 Diaphragm A ctuators S i z e 80 and 10 0 Contents Introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scope of Manual 1 . . . . . . . . . . . . . . . . . . . . . . . . . Description 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications 3 . . . . . . . . . . . . . ...

  • Emerson Process Management 667 - page 2

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 2 Table 1. Specifications SPECIFICATION ACTUATOR SIZE SPECIFICATION 80 100 Nominal Effective Diaphragm Area cm 2 1761 2902 Nominal Effective Diaphragm Area inch 2 273 450 Yoke Boss Diameters mm 127 127 178 Yoke Boss Diameters inch 5 5H (1) 7 Acceptable Valve Stem Diameters mm ...

  • Emerson Process Management 667 - page 3

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 3 Figure 2. Schematic Representation of Type 667 Actuator DIAPHRAGM AIR LIFTS SPRING PUSHES DOWN ACTUA TOR STEM TYPE 667 REVERSEĆACTING DIAPHRAGM ACTUA TOR AF3833-A A6127 / IL increases valve seat load on valve applications where additional seat-loading is necessary. Specific ...

  • Emerson Process Management 667 - page 4

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 4 When an actuator and valve are shipped together, the actuator is normally mounted on the valve. Follow the valve instructions when installing the control valve in the pipeline. If the actuator is shipped separately or if it is necessary to mount the actuator on the valve, pe ...

  • Emerson Process Management 667 - page 5

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 5 Adjustments Travel Make travel adjustments when the motion observed during actuator travel is different from the travel stamped on the actuator nameplate. If the Actuator Mounting procedure was followed correctly, this adjustment should not be necessary. When adjusting trave ...

  • Emerson Process Management 667 - page 6

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 6 For high spring forces, it is necessary to use spacers between the bottom of the yoke and the spring seat to isolate spring force from the adjusting nut. W ARNING To avoid personal injury from the compressed actuator spring snapping back to its original length, make and use ...

  • Emerson Process Management 667 - page 7

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 7 D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the valve. D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Reli ...

  • Emerson Process Management 667 - page 8

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 8 10. For actuators with a snubber (see figure 8): W ARNING To avoid personal injury due to the sudden, uncontrolled movement of parts, ensure the actuator spring is not under compression before removing the travel stop. a. Remove the travel stop (key 84). Be certain there is ...

  • Emerson Process Management 667 - page 9

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 9 Figure 4. Size 80 Actuator Construction CAP SCREW (KEY 12) SP ACER (KEY 2) UPPER DIAPHRAGM CASE (KEY 1) DIAPHRAGM (KEY 3) LOWER DIAPHRAGM PLA TE (KEY 71) CAP SCREW (KEY 30) GASKET (KEY 70) TRA VEL STOP (KEY 84) SEAL BUSHING (KEY 7) VENT ASSEMBL Y (KEY 17) UPPER DIAPHRAGM PLA ...

  • Emerson Process Management 667 - page 10

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 10 diaphragm. Do not exceed 68 N S m (50 lbf S ft) torque. 11. Insert the cap screws (key 13) into the diaphragm casing, and tighten the hex nuts (key 14) in the following manner. The first four hex nuts tightened should be diametrically opposed and 90 degrees apart. Tighten t ...

  • Emerson Process Management 667 - page 11

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 11 These instructions outline the procedure required to decrease high spring compression. Loosen the jam nut (key 26), and rotate the adjusting nut (key 25) until spring compression is relieved. 3. Remove the pressure tubing or piping from the top of the diaphragm casing. 4. F ...

  • Emerson Process Management 667 - page 12

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 12 Figure 5. Size 100 Actuator Construction DIAPHRAGM CASING COVER (KEY 15) UPPER DIAPHRAGM PLA TE (KEY 4) UPPER DIAPHRAGM CASING (KEY 1) DIAPHRAGM (KEY 3) CAP SCREW (KEY 13) BACK UP PLA TE (KEY 6) HEX NUT (KEY 14) DIAPHRAGM RET AINER (KEY 5) LOWER DIAPHRAGM CASING ASSEMBL Y ( ...

  • Emerson Process Management 667 - page 13

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 13 spring interferes with installation of the lower diaphragm casing, reposition the spring by rotating the adjusting nut (key 25). 4. Install the lower diaphragm casing, and secure it by tightening the four hex nuts. 5. Lubricate the seal bushing O-rings (keys 8 and 9) and th ...

  • Emerson Process Management 667 - page 14

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 14 For Actuators With the Top-Loaded Option Disassembly For key number locations refer to figure 7, and refer to the Top-Loaded Actuator Detail shown in figure 7. Also, refer to figure 5 for diaphragm construction details. 1. Remove the 40 cap screws (key 13) from the upper di ...

  • Emerson Process Management 667 - page 15

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 15 when the diaphragm adaptor (key 245, fig ur e 5) is in st all ed . CAUTION If the diaphragm (key 3) is installed so air pressure is applied to the fabric side, it will immediately delaminate the sealing surface (smooth surface) from the fabric. The delamination can cause im ...

  • Emerson Process Management 667 - page 16

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 16 18. Insert the cap screws (key 13) into the upper diaphragm casing (key 1), and finger tighten the screws. 19. Tighten the cap screws (key 13) in the following manner. The first four cap screws tightened should be diametrically opposed and 90 degrees apart. Tighten these fo ...

  • Emerson Process Management 667 - page 17

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 17 worm shaft (key 51). Thread the handwheel cap (key 127) onto the worm shaft. 6. Pack the two thrust bearings (key 43) with lithium grease lubricant. Install one thrust bearing; then install the worm gear (key 44), followed by the second thrust bearing and the bearing and ge ...

  • Emerson Process Management 667 - page 18

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 18 Assembly 1. The front and back worm retainers (keys 48 and 49) each have a slot in their threads for a set screw (key 52). Pack the ball bearings (key 50) with lithium grease, and insert one ball bearing into the back worm retainer (key 48). 2. Thread the back worm retainer ...

  • Emerson Process Management 667 - page 19

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 19 Key Description Part Number 8* O-Ring, nitrile (2 required) Size 80 1D542906992 Size 100 1H8627X0042 9* O-Ring, nitrile Size 80 1D439206992 Size 100 1R834206992 10 Seal Bushing Retainer 11 Cap Screw 12 Cap Screw 13 Cap Screw 14 Hex Nut 15 Diaphragm casing Cover 16 Cap Screw ...

  • Emerson Process Management 667 - page 20

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 20 Key 18 Spring, steel ACTUATOR SIZE RANGE TRAVEL COMPRESSION RATE MAXIMUM LOAD PART NUMBER COLOR CODE SIZE bar psi mm Inches N/mm Lb/in N Lb NUMBER CODE 0.2-1 3-15 76 3 175.1 1000 25,042 5630 1H747727082 Red 0.2-1 3-15 51 2 288 9 1650 35 139 7900 1H747527082 Lt Blue 0.3-1.7 ...

  • Emerson Process Management 667 - page 21

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 21 Figure 6. Size 80 Type 667 Actuator NOTE: KEYS 243, 244, 245, AND 246 ARE NOT SHOWN. 50A8597-D / DOC 50A8599-C APPL Y LUB/SEALANT TOPĆLOADED ACTUA TOR DET AIL ...

  • Emerson Process Management 667 - page 22

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 22 Figure 7. Size 100 Type 667 Actuator NOTES: THIS P ART IS LOCATED 90 _ T O FRONT OF POSITION SHOWN 2. KEYS 243 AND 244 ARE NOT SHOWN 1 APPL Y LUB 50A2623-F / DOC 56A9820-B / DOC TOPĆLOADED ACTUA TOR DET AIL ...

  • Emerson Process Management 667 - page 23

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 23 Figure 8. Size 80 Type 667 Actuator with Side-Mounted Handwheel and Hydraulic Snubber VIEW A SECTION BĆB B B VIEW A APPL Y LUB/SEALANT 50A8759-C / DOC ...

  • Emerson Process Management 667 - page 24

    667 Size 80 and 100 Actuators Instruction Manual Form 1432 December 2007 24 Figure 9. Size 100 Top-Mounted Handwheel APPL Y LUB 50A2624-F / DOC Emerson Process Management Marshalltown, Iowa 50158 USA Cernay 68700 France Sao Paulo 05424 Brazil Singapore 128461 www.Fisher.com The contents of this publication are presented for informational purposes o ...

Produzent Emerson Process Management Kategorie Automobile Parts

Dokumente, die wir vom Produzenten des Geräts Emerson Process Management 667 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson Process Management
- Bedienungsanleitungen 667
- Produktkarten Emerson Process Management
- Informationsbroschüren
- oder Energieetiketten Emerson Process Management 667
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson Process Management 667.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson Process Management 667, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson Process Management 667. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson Process Management 667 ansehen.

Die komplette Bedienungsanleitung des Geräts Emerson Process Management 667, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson Process Management 667 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson Process Management 667 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson Process Management sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson Process Management 667 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson Process Management 667 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson Process Management 667, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson Process Management 667 - die uns die ersten Schritte während der Nutzung von Emerson Process Management 667 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson Process Management 667 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson Process Management 667 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson Process Management 667?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson Process Management 667 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson Process Management 667 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)