Bedienungsanleitung Enviro 50-1096

31 Seiten 2.54 mb
Download

Zur Seite of 31

Summary
  • Enviro 50-1096 - page 1

    SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f or use with other gas ...

  • Enviro 50-1096 - page 2

    FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the need ...

  • Enviro 50-1096 - page 3

    T able of Contents 3 Safety Precautions.....................................................................................................2 T able of Contents......................................................................................................3 Codes And Approv als.................................................................. ...

  • Enviro 50-1096 - page 4

    DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved f or installations from 0 feet to 4500 feet (1372 m) abo ve sea level. BV: This V ented appliance dra ws all of its combust ...

  • Enviro 50-1096 - page 5

    Specific a tions R ATING L ABEL L OCATION : The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the replace. D IMENSIONS : Surround Style Distance Direct V ent B-V ent Arched Surround From Flue T o Surround 14 11 / 16 ” (376 mm) 14 9 / 16 ” (370 mm) From Back/Sensor T o Surround ...

  • Enviro 50-1096 - page 6

    6 Specific a tions 15 1 / 16 " (383 mm) 30 1 / 2 " (775 mm) With Trim 33 3 / 16 " (343 mm) Without Trim 33" (338 mm) 20 5 / 8 " (523 mm) 22 3 / 4 " (577 mm) 22 11 / 16 " (576 mm) With Trim 46 1 / 8 " (1171 mm) Without Trim 46" (1168 mm) 21" (533 mm) 13 1 / 16 " (333 mm) 1 3 / 8 " (36 mm) 1 ...

  • Enviro 50-1096 - page 7

    7 WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 3. Lighting instruction label. 1. STOP! Read the safety information above on this label. 2. T urn off all electrical power to this appliance. 3. T urn off the ga ...

  • Enviro 50-1096 - page 8

    8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating A) Make sure the pilot is lit. B) T urn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) T urn HI/LO knob to the desired ame height. E) T urn on all electrical power to the unit. NOTE: Check that all burner ...

  • Enviro 50-1096 - page 9

    9 Maintenance And Ser vice Warning: F ailure to position the parts in accordance with this manual, or f ailure to use only parts specically approved with this appliance, ma y result in property damage or personal injury . At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the bu ...

  • Enviro 50-1096 - page 10

    F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a re, explosion or production of carbon monoxide ...

  • Enviro 50-1096 - page 11

    Initial Inst alla tion WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. C LEARANCES TO C OMBUSTIBLES : Maintain sufcient clearances f or operation, service and maintenance. • A clearance of 25 ” (648 mm) minimum is re ...

  • Enviro 50-1096 - page 12

    12 Initial Inst alla tion Check draft with a match or smoke in a " (6 mm) tube located here. M INIMUM F IREPLACE S IZE : Description of Fireplace Dimension Direct V ent B-V ent Width At Back 23 ” (591 mm) 23 ” (591 mm) At Front 35” (889 mm) 35” (889 mm) Height With Surround Only 23 ” (603 mm) 23 ” (603 mm) With Surro ...

  • Enviro 50-1096 - page 13

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y D IRECT V ENT M ODEL : WARNING: This appliance has been designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations. This model is vented with two (2) 3” aluminum or stainless steel ex vent leadi ...

  • Enviro 50-1096 - page 14

    14 In s t al l s e a le d t h ro a t c o nn e c to r o r flashing to prevent leakage of room air up through chimney . DV O n l y: B e f o re i n s t al l i n g ve n t liners, mark each liner on both ends to designate which is the intake and the exhaust. Me as ur e t he h ei g ht o f th e c hi mn ey b e f o r e h a n d a n d p u r c h a s e t h e ap ...

  • Enviro 50-1096 - page 15

    15 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : F an Control Black White White Black Green/Y ellow Green Black Power Cord 120V AC F AN 120 o F (49 o C) T emperature Sensor CNT2 CNT3 CNT1 CNT4 The fan is thermostatically controlled and it will not oper ate if the appliance is cold. A few minutes after the appliance ...

  • Enviro 50-1096 - page 16

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y G AS L INE C ONNECTION : Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: •This replace is equipped with a certi ed exible pipe located on the right side of the unit, terminating in a ” male NPT  ...

  • Enviro 50-1096 - page 17

    17 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y C ONVERTING A D IRECT V ENT F IREPLACE T O A B-V ENT F IREPLACE : Direct V ent Connector Assembly Fresh Air Inlet Covers 1. Remove the Direct V ent chimney connector assembly by taking out the two (2) T -20 screws at the front of the unit. Push the assembly out from under the brackets at the bac ...

  • Enviro 50-1096 - page 18

    Second ar y Inst alla tion QUALIFIED INST ALLERS ONL Y R EPLACING THE B LOWER : 1. T urn the unit off and allow the unit to cool completely . 2. Remove the f ascia or louvers, open the door (see “ D OOR R EMO VAL ”) , and remo ve the log set. 3. Remove the log support tray by lifting the back of the tray up and pul l it out from under the lip. ...

  • Enviro 50-1096 - page 19

    19 Second ar y Inst alla tion Figure 23: Filler panel with trim installation. D OOR R EMOVAL : Figure 19: Top bolts for glass door. Figure 20: Bottom hooks for glass door. Open the door by removing the two (2) 5 / 16 ’’ bolts located at the top outside corners of the glass frame (see Figure 19). Lift the bottom of the door up and remove from un ...

  • Enviro 50-1096 - page 20

    Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : NOTE: The logs are fragile and should be handled gently. The placement of the logs is not arbitr ary . If they are positioned incorrectly , the ames can be “pinched” and will not burn correctly . The burner , and a few of the logs come with locator pins, notches and ledges, whic ...

  • Enviro 50-1096 - page 21

    21 Second ar y Inst alla tion Figure 27. Third Stage Log Set Installation. Figure 29. Fifth Stage Log Set Installation. Figure 28. Fourth Stage Log Set Installation. Figure 28: Once the logs are in position the provided rock wool can be placed irregularly in front of the burner . Figure 29: Place the embers irregularly onto and around the front of ...

  • Enviro 50-1096 - page 22

    Second ar y Inst alla tion Figure 30. Sienna complete log set-up with embers burning. NO TE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot. When lighting the replace for the rst time since the log set and embers have been installed/replaced, watch for ignition at ALL the burner ports. If ...

  • Enviro 50-1096 - page 23

    23 Second ar y Inst alla tion R EMOVING T HE B RICK P ANEL : The brick panel set is fragile, handle with extreme care. The brick panel set comes pre-installed. The centre and top panel are the only panels that need to be removed if the complete gas and electrical tray assembly must be removed. The side panels may remain installed unless they are to ...

  • Enviro 50-1096 - page 24

    T rouble Shooting Problem Possible Cause Solution Spark will not arc to the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor • Check connections to ignitor . • If ignitor connections are good but no spark, replace ignitor . Broken spark electrode • Check for brok en ceramic insulation, replace electrode if broken. Mis ...

  • Enviro 50-1096 - page 25

    P ar ts List- Unit Components Reference Number Part Description Part Number 1 120°F Ceramic Fan T emperature Sensor EC-001 2 300°F (149°C) Manual Reset Spill Switch (Normally Closed) EC-003 3 S.I.T . Nova V alve NG (50% turn down) EC-006 3 S.I.T . Nova V alve LP (50% turn down) EC-007 4 Thermocouple EC-009 4 Spark Electrode with Ignitor Cable EC ...

  • Enviro 50-1096 - page 26

    26 P ar ts Diagr am - Components SIENNA - Components October 2004            ...

  • Enviro 50-1096 - page 27

    27 P ar ts Diagr am - Burner SIENNA - Burner October 2004              ...

  • Enviro 50-1096 - page 28

    P ar ts List - Options Reference Number Option Description Part Number 1A The Cottage T rim Kit - Gold 50-548 1A The Cottage T rim Kit - Pewter 50-549 1A The Cottage T rim Kit - Antique Copper 50-550 1A The Cottage T rim Kit - Painted Charcoal 50-694 2A Cape Cod Doors 50-1097 3A Unit Panel & Keystone 50-1 108 4A Cottage 50-1 109 5A Filler Panel ...

  • Enviro 50-1096 - page 29

    29 P ar ts Diagr am - Options SIENNA - Options October 2004        ...

  • Enviro 50-1096 - page 30

    30 W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arrant y on this gas product. This Limited Lifetime W arrant y covers the appliance for a period of seven years from the date of installation. This warrant y applies only to the original owner in the original location. Covered under the lifetime warr anty are: the surround, the chas ...

  • Enviro 50-1096 - page 31

    Inst alla tion Da t a Sheet The following information must be recorded by the installer for w arranty purposes and f uture reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:__________________ ...

Produzent Enviro Kategorie Stove

Dokumente, die wir vom Produzenten des Geräts Enviro 50-1096 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Enviro
- Bedienungsanleitungen 50-1096
- Produktkarten Enviro
- Informationsbroschüren
- oder Energieetiketten Enviro 50-1096
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Enviro 50-1096.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Enviro 50-1096, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Enviro 50-1096. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Enviro 50-1096 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Enviro 50-1096, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Enviro 50-1096 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Enviro 50-1096 verständlich ist.

Eine gänzliche Bedienungsanleitung von Enviro sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Enviro 50-1096 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Enviro 50-1096 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Enviro 50-1096, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Enviro 50-1096 - die uns die ersten Schritte während der Nutzung von Enviro 50-1096 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Enviro 50-1096 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Enviro 50-1096 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Enviro 50-1096?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Enviro 50-1096 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Enviro 50-1096 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)