    STUDER INNOTEC TEL : ++41 (0)27 205 60 80 Rue des Casernes 57 FAX : ++41 (0)27 205 60 88 CH – 1950 Sion E-MAIL : info@studer-innotec.com User’s and installer’s Manual Sine wave Inverter, Battery charger, Transfersystem XP-COMPACT - XPC 1400-12 XP-COMPACT - XPC 2200-24 XP-COMPACT - XPC 2200-48 Temperature sensor CT-35 Remote control RCC-01 Sol ...

  • Studer Innotec C-IP23 - page 2

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 2/77 English description .................................................................................................................. 5 1 General Information ......................................................................................... 5 1.1 Operating instructions ......................... ...

  • Studer Innotec C-IP23 - page 3

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 5/77 English description 1 General Information 1.1 Operating instructions This manual is part of the delivery pa ckage of every XP-COM PACT inverter-charger. It serves as guidelines for safe and e fficient operation of XP-COMPACT. The instructions are only valid for use with the following devices and option ...

  • Studer Innotec C-IP23 - page 4

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 6/77 − Damage from atmospheric over voltage (lightning) 1.4 Liability Disclaimer Respecting this manual, servicing and method of installation, functioning, application and maintenance of the appliance can not be controlled or supe rvised by STUDER INNOTEC. Hence we do not accept any liability and responsi ...

  • Studer Innotec C-IP23 - page 5

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 7/77 − Plenty of fresh water and soap must be ready at hand so that in case of acid coming in contact with skin, eyes and cl othes, the areas in question can be thoroughly washed. − If acid enters the eyes, you must thor oughly wash them with cold running water for at least 15 minutes. It is recommended ...

  • Studer Innotec C-IP23 - page 6

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 8/77 connection between Neutra l and earth in inverter mode only may be done by installing a bridge internally to the unit. Please contact your installer regarding th is point. (2) Remote control for remote adjustment of the input limi t. (see chap. 4.6.3) 2.2 Description of the main functions 2.2.1 The inv ...

  • Studer Innotec C-IP23 - page 7

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 9/77 2.3 Battery connecting Lead-acid batteries are normally available in blocks of 2V, 6V or 12V. In most cases, to generate the necessary operating voltage and the capacity of the batteries for the XP-COMPACT many batteries have to be c onnected together in parallel and or in series. Here are 3 examples o ...

  • Studer Innotec C-IP23 - page 8

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 10/77 3 Mounting and installing 3.1 Installation place The location of the XP-COMPACT must be driven by the following criteria: − Protection from unauthorized handling − Dry dust free room, no condensation − Never install directly over the battery and never in a cabinet together with the batteries − ...

  • Studer Innotec C-IP23 - page 9

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 11/77 3.3.2 Protection cover of the terminals connections The protection is available as an option (Order ref. CFC-01) and avoid to do wrong hazardous connection on the termi nals 230Vac. It mounted with strain relief clamps for the cable. 3.4 Connection Plan A Battery +/- Battery cable (already installed) ...

  • Studer Innotec C-IP23 - page 10

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 12/77 3.5 Cabling Connecting the XP-COMPACT is a very important step of t he installation. You must take care that all connection work is ca rried out in a clean and correct way and that under no circumstance a cable is connected to a wrong terminal. Connecting of the XP-COMPACT must be carried out in the f ...

  • Studer Innotec C-IP23 - page 11

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 13/77 3.6.4 Connect the solar modules: SO LAR +/- (Only for solar option) Solar modules are connected on these termi nals. Under no circ umstances should any other energy source i.e. wind generator be connected to these terminals! Only solar modules must be connected with two cabl es +/-. Depending on the p ...

  • Studer Innotec C-IP23 - page 12

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 14/77 4.2 Display and control parameters on remote control panel (optional) 4.3 Light Emitting Diodes (LED) LED Marking LED lit LED blinks 1 AC IN Voltage corresponding to self-adjusted values is at the AC IN input. A voltage outside the self-adjusted values is at the AC IN input, or the XP- COMPACT is in s ...

  • Studer Innotec C-IP23 - page 13

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 15/77 10 Over Temp. For the time being the XP-COMPACT is out of service because of overheating. 11 Overload The XP-COMPACT is out of service because of overload or short- circuit 12 Batt. Low/High Battery voltage is too low Battery voltage is or was to high 13 OFF XP-COMPACT is turned off. Turning it back o ...

  • Studer Innotec C-IP23 - page 14

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 16/77 4.6.1 Charge detection system „Standby“ In order to avoid unnecessary discharge of the battery, the inve rter switches OFF automatically if no appliance is connect ed and switches ON aut omatically again if appliance is connected. The LED 8 blinks if the inverter is in Standby-Mode. The switching- ...

  • Studer Innotec C-IP23 - page 15

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 17/77 at the input (LED 1 AC IN is lit), the Ba ttery Charger is switc hed on automatically (LED 2 CHARGER is lit). The battery is fu lly automatically charged matching to the charge level, the adjusted vo lt-age levels and the charge current. Thanks to the built- in Float Charge System, t he batteries can ...

  • Studer Innotec C-IP23 - page 16

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 18/77 Equalization mode should never be used when using Gel-Batteries. 4.7.4 Charging current The maximum charging current for the ba ttery can be adjusted with the Turning Knob 22 (CHARGER). The charging current of the battery should be set to approximately 10 – 20% of the battery capacity (at C10). This ...

  • Studer Innotec C-IP23 - page 17

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 19/77 lit. The inverter is switched off and the batte ry charger switched on. This process is automatic, unless the charger mo de or the transfer mode is disabled (see Chap. 5.5). The maximum current of the Tr ansfer switch is 16A. That means through this system, consuming devices up to a maximum of al 3700 ...

  • Studer Innotec C-IP23 - page 18

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 20/77 4.9 The Solar charge controller (option) The XP-COMPACT also has a Solar Charge Controller built in. For charging the batteries, Solar modules can be connected to the screw terminal SOLAR +/-. The in- built controller is a „Shunt controller“ for the maximum input current of 30A for XPC 1400-12 and ...

  • Studer Innotec C-IP23 - page 19

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 21/77 4.11 The Remote Control RCC-01 As an option, a Remote Control can be connected to the XP-COMPACT. All operating controls and displays except from level adjustment are available on the Remote Control. The Remote Control is supplied with a 20m long cable. It can as long as 40m. The Remote Control is sui ...

  • Studer Innotec C-IP23 - page 20

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 22/77 5 Programming (possible only wi th the remote control RCC-01) The XP-COMPACT (except for 60Hz versi ons) is equipped with a Flash processor fitted out with EEPROM Memory, which means that even w hen it is disconnected from the battery, the para meters that were programmed for the application remain af ...

  • Studer Innotec C-IP23 - page 21

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 23/77 With the Push Button 19 (Change status) se t the desired parameter (voltage or time) to modify (LED 14/ 15/16/17/18). Push Bu tton 19 (Change status) to set the desired value according to the table 5.3.2. If desired, repeat the operatio n with any other parameter (voltage or time) to be changed. If du ...

  • Studer Innotec C-IP23 - page 22

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 24/77 are automatically stored and the XP- COMPACT switches back to normal operating condition. 5.4.3 Auxiliary Contact as generator starter As per the battery capacity When in the programming of t he Auxiliary Contact, the Ba ttery Capacity (LED 15-18) is used as a condition, you must then ta ke note of th ...

  • Studer Innotec C-IP23 - page 23

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 25/77 The Auxiliary Contact can be operated at any time wit h the Push Button 21 (AUX. CONTACT). The LED 6 „Contact manual“ lights up as information that the Contact is manually operated, and LED 5 „Contact active “ lights up when the Contact is active. By pushing the Push Button 21 a second time, t ...

  • Studer Innotec C-IP23 - page 24

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 26/77 6 Installation Maintenance Apart from the periodic controls mentioned for the connections, the XP-COMPACT does need any maintenance. Keep the appliance clean and from time to time, wipe it clean with a damp cloth. 7 Declaration of CE Compliance Hereby we state that the products described in this user ...

  • Studer Innotec C-IP23 - page 25

    STUDER INNOTEC XP-COMPACT XP-COMPACT V5.4 27/77 8 Technical Data ...

Produzent Studer Innotec Kategorie Battery Charger

Dokumente, die wir vom Produzenten des Geräts Studer Innotec C-IP23 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Studer Innotec
- Bedienungsanleitungen C-IP23
- Produktkarten Studer Innotec
- Informationsbroschüren
- oder Energieetiketten Studer Innotec C-IP23
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Studer Innotec C-IP23.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Studer Innotec C-IP23, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Studer Innotec C-IP23. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Studer Innotec C-IP23 ansehen.

Die komplette Bedienungsanleitung des Geräts Studer Innotec C-IP23, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Studer Innotec C-IP23 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Studer Innotec C-IP23 verständlich ist.

Eine gänzliche Bedienungsanleitung von Studer Innotec sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Studer Innotec C-IP23 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Studer Innotec C-IP23 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Studer Innotec C-IP23, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Studer Innotec C-IP23 - die uns die ersten Schritte während der Nutzung von Studer Innotec C-IP23 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Studer Innotec C-IP23 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Studer Innotec C-IP23 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Studer Innotec C-IP23?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Studer Innotec C-IP23 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Studer Innotec C-IP23 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)