    Page 1 01/13 *2P0113* 507138-01 *P507138-01*  2013 Lennox Industries Inc. Dallas, T exas, USA UPFLOW HORIZONT AL LEFT HORIZONT AL RIGHT AIR FLOW AIR FLOW AIR FLOW INST ALLA TION INSTRUCTIONS EL180UHE ELITE ® SERIES GAS FURNACE UPFLOW / HORIZONT AL AIR DISCHARGE 507138-01 01/2013 THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE T ...

  • Lennox International Inc. EL180UHE - page 2

    Page 2 Unit Dimensions - inches (mm) AIR FLOW 23 (584) (19) 3/4 (19) 1 Bottom Return Air Opening GAS PIPING INLET (Either Side) Side Return Air Opening (Either Side) 1 Bottom Return Air Opening FLUE OUTLET (T op) ELECTRICAL INLET (Either Side) SUPPL Y AIR OPENING FRONT VIEW SIDE VIEW TOP VIEW A B 9/16 (14) C D 3/4 27−3/4 (705) 19−7/16 (494) 23? ...

  • Lennox International Inc. EL180UHE - page 3

    Page 3 EL180UHE Gas Furnace The E L180UHE unit is s hipped ready f or installation i n the upflow o r horizontal right position ( for horizontal left p osi tion the combustion air pressure switch must be moved) fueled b y n atural gas. A conversion kit ( ordered separate ly) i s required for u se i n L P/Propane gas applications. T he furnace ...

  • Lennox International Inc. EL180UHE - page 4

    Page 4 Installed in Combination with a Cooling Coil When this furnace is used with cooling units, it shall be installed in p arallel with, or on the upstream s ide of, cooling units to avoid condensation in the heating compartment. See f igure 1. W ith a parallel flow arrangement, a d amper (or other means t o control t he flow of air) m u st adequ ...

  • Lennox International Inc. EL180UHE - page 5

    Page 5  Do not install the furnace where drafts might blow direct ly into it. This could cause improper combustion and un safe operation.  Do not block the furnace combustion air openings with clothing, boxes, doors, etc. Air is needed for proper combustion and safe unit operation.  When the furnace is installed in an attic or other ...

  • Lennox International Inc. EL180UHE - page 6

    Page 6 separated b y a door . Though an area may appear to be un confined, it might be necessary to bring in outdoor air for combustion if t he str ucture does not provide enough air by infiltration. If the furnace is located in a building of tight construction with weather stripping and caulking around the windows and doors, follow the procedur ...

  • Lennox International Inc. EL180UHE - page 7

    Page 7 EQUIPMENT IN CONFINED SP ACE ALL AIR FROM OUTSIDE (Inlet Air from Crawlspace and Outlet Air to V entilated Attic) NOTE-The inlet and outlet air openings shall each have a free area of at least one square inch (645 mm 2 ) per 4,000 Btu (1.17 kW) per hour of the total input rating of all equipment in the enclosure. VENTILA TION LOUVERS (Each e ...

  • Lennox International Inc. EL180UHE - page 8

    Page 8 Setting Equipment W ARNING Do not install the furnace on its front or its back. Do no t connect the return air ducts to the back of the fur nace. Doing so w ill adversely affect the operation of the safety control devices, which could result in per sonal injury or death. The EL180UHE gas furnace can be i nstalled a s s hipped in either ...

  • Lennox International Inc. EL180UHE - page 9

    Page 9 Return Air -- Upflow Applications Return air can be brought in t hrough the bottom or either side o f the furnace i nstalled i n a n u pflow a pplication. I f t he furnace i s installed o n a p latform w ith b ottom r eturn, make an a irtight s eal between the bottom of the furnace and the platform t o ensure that the furnace operates proper ...

  • Lennox International Inc. EL180UHE - page 10

    Page 10 Removing the Bottom Panel Remov e the two screws that secure the bottom cap to the furnace. Pivot the bottom cap down to release the bottom panel. Once the bottom panel has been removed, reinstall the bottom cap. See figure 10. Removing the Bottom Panel FIGURE 10 Screw Bottom Panel Bottom Cap Horizontal Application Installation Clearances T ...

  • Lennox International Inc. EL180UHE - page 11

    Page 1 1 CAUTION If this unit is being installed in a space serviced by an exhaust fan, power exhaust fan, or other device which may create a negative pressure in the space, take care when sizing the inlet air opening. The in let air opening must be sized to accommodate the maximum volume of exhausted air as well as the maximum volume of combust ...

  • Lennox International Inc. EL180UHE - page 12

    Page 12 Return Air Plenum NOTE - Return air must not be drawn from a room where this furnace, or any other gas-fueled appliance (i.e., water heater), or carbon monoxide producing de vice (i.e., wood fireplace) is installed. When return air is drawn from a room, a negative pres  sure i s c reated i n t he r oom. I f a g as appliance is oper ...

  • Lennox International Inc. EL180UHE - page 13

    Page 13 UPFLOW POSITION Left Side V ent Discharge FIGURE 16  Gas supply piping must be brought into the unit from the right side in order to accommodate the flue pipe.  Cut Combustion air inducer tubing from 9” to 8” to avoid inter ference with inducer motor  Remove make-up box assembly (2 screws) and cut wire tie to free make-up bo ...

  • Lennox International Inc. EL180UHE - page 14

    Page 14 HORIZONT AL RIGHT POSITION T op V ent Discharge FIGURE 20  Remove make-up box assembly (2 screws) and cut wire tie to free make-up box wires. Re-install make-up box on other side of cabinet.  Re-secure make-up box wires: Either pull excess wires through the blower compartment and secure using supplied wire tie, or coil excess wire and ...

  • Lennox International Inc. EL180UHE - page 15

    Page 15 FLUE TRANSITION COLLAR VENT PIPE (min. 6” length) “DISCONNECTED VENT” WARNING STICKER FIGURE 22 FLUE TRANSITION COLLAR VENT CONNECTION UPFLOW AND HORIZONT AL POSITION VENT PIPE (min. 6” length) “DISCONNECTED VENT” WARNING STICKER FIGURE 23 Common V enting Using Metal-Lined Masonry Chimney 4 in. (102 mm) minimum MIN. LENGTH -- AS ...

  • Lennox International Inc. EL180UHE - page 16

    Page 16 A type B or listed chimney lining system that passes through an unused masonry chimney flue is not considered to be exposed to the outdoors. General V enting Requirements V ent all EL180UHE furnaces according to these instruc tions: 1 - V ent diameter recommendations and maximum allow able piping runs are found in the provided venting ...

  • Lennox International Inc. EL180UHE - page 17

    Page 17 9 - If the common vertical vent is of fset, the maximum common vent capacity listed in the common venting tables should be reduced by 20%, the equivalent of two 90° elbows (0.80 x maximum common vent capacity). The horizontal length of the offset shall not exceed 1‐1/2 feet (.46 m) for each inch (25 mm) of common vent diameter . 10 - The ...

  • Lennox International Inc. EL180UHE - page 18

    Page 18 T ABLE 3 Capacity of T ype B Double-W all V ents with T ype B Double-Wall Connectors Serving a Single Category I Appliance Height H (feet) Lateral L (feet) V ent and Connector Diameter - D (inches) 3 Inch 4 Inch 5 Inch 6 Inch Appliance Input Rating in Thousands of Btu Per Hour MIN MAX MIN MAX MIN MAX MIN MAX 6 0 0 78 0 152 0 251 0 375 2 13 ...

  • Lennox International Inc. EL180UHE - page 19

    Page 19 T ABLE 4 V ent Connector Capacity T ype B Double-W all V ents with T ype B Double-Wall Connectors Serving T wo or More Category I Appliances V ent Height H (feet) Connector Rise R (feet) V ent and Connector Diameter - D (inches) 3 Inch 4 Inch 5 Inch 6 Inch Appliance Input Rating in Thousands of Btu Per Hour MIN MAX MIN MAX MIN MAX MIN MAX 6 ...

  • Lennox International Inc. EL180UHE - page 20

    Page 20 Removal of the Furnace from Common V ent In the event that an existing furnace is removed from a venting system commonly run with separate gas ap pliances, the venting system is likely to be too large to properly vent the remaining attached appliances. Conduct t he f ollowing test while e ach a ppliance i s operat ing a nd the o ther ...

  • Lennox International Inc. EL180UHE - page 21

    Page 21 T ABLE 6 Gas Pipe Capacity - ft 3 /hr (m 3 /hr) Nominal Iron Pipe Size inches (mm) Internal Diameter inches (mm) Length of Pipe - feet (m) 10 (3.048) 20 (6.096) 30 (9.144) 40 (12.192) 50 (15.240) 60 (18.288) 70 (21.336) 80 (24.384) 90 (27.432) 100 (30.480) 1/2 (12.7) .622 (17.799) 172 (4.87) 11 8 (3.34) 95 (2.69) 81 (2.29) 72 (2.03) 65 (1.8 ...

  • Lennox International Inc. EL180UHE - page 22

    Page 22 GROUND JOINT UNION DRIP LEG MANUAL MAIN SHUT-OFF VA LV E GROUND JOINT UNION DRIP LEG MANUAL MAIN SHUT-OFF VA LV E GROUND JOINT UNION DRIP LEG MANUAL MAIN SHUT-OFF VA LV E Horizontal Applications Possible Gas Piping Configurations Horizontal Application Left-Side Air Discharge Horizontal Application Right-Side Air Discharge NOTE - BLACK IRON ...

  • Lennox International Inc. EL180UHE - page 23

    Page 23 INTERIOR MAKE-UP BOX INST ALLA TION FIGURE 28 BOX Right Side Refer to figure 2 9 for schematic wiring diagram, field wiring and trouble shooting. The power supply wiring must meet Class I restrictions. Protected by either a fuse or circuit breaker , select circuit protection and wire size according to unit nameplate. NOTE - Unit nameplate s ...

  • Lennox International Inc. EL180UHE - page 24

    Page 24 FIGURE 2 9 EL180UHE Schematic Wiring Diagram ...

  • Lennox International Inc. EL180UHE - page 25

    Page 25 Integrated Control RED LED Flash Code Diagnostic Codes / Status of Furnace Off No power to control or board fault detected On Board fault detected, Heartbeat 1 Control powered - displayed during all modes of operation if no errors are detected 1 Reverse Line V oltage Polarity 2 Improper Earth Ground 3 Burner failed to light, or lost flame d ...

  • Lennox International Inc. EL180UHE - page 26

    Page 26 Unit Start-Up FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING Do not use this furnace if any part has been under  water . A flood-damaged furnace is extremely dan gerous. Attempts to use the furnace can result in fire or explosion. Immediately call a qualified ser vice t echnician to inspect the f urnace a nd t o r eplace all g as c ...

  • Lennox International Inc. EL180UHE - page 27

    Page 27 1 1 - Are flame rollout switches tripped? If flame rollout switches are tripped, call the service technician for in spection. Heating Sequence Of Operation (follow steps below or see Figure 29 for more detail) 1 - Whe n thermostat calls for heat, combustion air blower starts. 2 - Combustion air pressure switch proves blower opera tion ...

  • Lennox International Inc. EL180UHE - page 28

    Page 28 T ABLE 10 Manifold Pressure Settings at all Altitudes Model Input Size Gas 0-2000 ft 2001-4500 ft. 4501-7500 ft 7501 - 10,000 ft Line Pressure in.wg. Min Max 045 Nat 3.5 3.2 3.0 3.5 4.5 13.0 LP/propane 10.0 10.0 10.0 10.0 1 1.0 13.0 070 Nat 3.5 3.2 2.8 3.5 4.5 13.0 LP/propane 10.0 10.0 10.0 10.0 1 1.0 13.0 090 Nat 3.5 3.2 2.7 3.5 4.5 13.0 L ...

  • Lennox International Inc. EL180UHE - page 29

    Page 29 HEA T F AN‐OFF TIME IN SECONDS T o adjust fan-off timing, reposition jumper across pins to achieve desired setting. NO JUMPER FIGURE 32 60 90 120 180 60 90 120 180 60 90 120 180 60 90 120 180 60 Second off T ime 90 Second off T ime 120 Second off T ime 180 Second off T ime Constant T orque Motor EL180UHE units a re equipped w ith a consta ...

  • Lennox International Inc. EL180UHE - page 30

    Page 30 2 - Label the wires from gas valve, rollout switches, prima ry limit switch and make-up box then disconnect them. 3 - Disconnect gas supply piping. Remove the screw se curing the burner box cover and remove cover . Re mo ve the four screws securing the burner manifold as sembly to the vestibule panel and remove the assembly from ...

  • Lennox International Inc. EL180UHE - page 31

    Page 31 Start-Up & Performance Check List Unit Model Number_______________ Serial Number___________________ UNIT SET UP (typical) Gas Supply Pressure 1 2 2 1 SUPPL Y AIR Line V oltage 3 4 5 Filter RETURN AIR RETURN AIR GAS SUPPL Y Natural Gas LP/Propane Gas Piping Connections Tight Leak T ested Supply Line Pressure “ W .C.________ 1 VENT / EX ...

  • Lennox International Inc. EL180UHE - page 32

    Page 32 Contractor's: Name_________________________T elephone_____________Checklist Completed____________________ Job Address_____-________________________________T echnician's Name___________________________________ UNIT OPERA TION (typical) 1 HEA TING MODE GAS MANIFOLD PRESSURE “W .C._____ COMBUSTION SAMPLE CO 2 % ______ CO PPM_______ ...

Produzent Lennox International Inc. Kategorie Furnace

Dokumente, die wir vom Produzenten des Geräts Lennox International Inc. EL180UHE erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lennox International Inc.
- Bedienungsanleitungen EL180UHE
- Produktkarten Lennox International Inc.
- Informationsbroschüren
- oder Energieetiketten Lennox International Inc. EL180UHE
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lennox International Inc. EL180UHE.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lennox International Inc. EL180UHE, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lennox International Inc. EL180UHE. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lennox International Inc. EL180UHE ansehen.

Die komplette Bedienungsanleitung des Geräts Lennox International Inc. EL180UHE, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lennox International Inc. EL180UHE hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lennox International Inc. EL180UHE verständlich ist.

Eine gänzliche Bedienungsanleitung von Lennox International Inc. sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lennox International Inc. EL180UHE bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lennox International Inc. EL180UHE befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lennox International Inc. EL180UHE, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lennox International Inc. EL180UHE - die uns die ersten Schritte während der Nutzung von Lennox International Inc. EL180UHE erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lennox International Inc. EL180UHE hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lennox International Inc. EL180UHE im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lennox International Inc. EL180UHE?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lennox International Inc. EL180UHE nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lennox International Inc. EL180UHE hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)