Bedienungsanleitung Fujitsu PRIMERGY RX300 S5

24 Seiten Betrifft nicht
Download

Zur Seite of 24

Summary
  • Fujitsu PRIMERGY RX300 S5 - page 1

    PRIMERGY RX300 S5 System configurator and order-information g uide Contents Instructions Configuration diagr am Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible driv es VI Hard disk drives VII PCI Controller VIII Communication/Network IX System M anagement Products ( RemoteView ) X Mi scellaneous XI Count ...

  • Fujitsu PRIMERGY RX300 S5 - page 2

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/System-Architect. Only these tools will ensure a fast and proper configur ation of your PRIMERGY server or yo ur complete PRIMER ...

  • Fujitsu PRIMERGY RX300 S5 - page 3

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Configuration diagram PRIM ERGY RX300 S5 Sy stem unit ( I ) with 3.5" Hard disk drives Moth erboard front side Memory CPU1 ( Channel 0 + 1 +2 ) 3 USB Bank 1 (3 Modules) Xeo n DP Air channel VGA Bank 2 (3 Modules) Frontp. Bank 3 (3 Modules) Bay for LocalView ...

  • Fujitsu PRIMERGY RX300 S5 - page 4

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Configuration diagram PRIM ERGY RX300 S5 Sy stem unit ( I ) with 8 or 12 2.5" Hard disk drives Moth erboard front side Memory CPU1 middle ( Channel 0 + 1 +2 ) 3 USB Bank 1 (3 Modules) Xeo n DP Air channel VGA Bank 2 (3 Modules) Frontp. Bank 3 (3 Modules) Ba ...

  • Fujitsu PRIMERGY RX300 S5 - page 5

    System c onfigurator and or der-information guide Start PRIMER GY RX300 S5 PRIMERGY RX 300 S5 Status 2010-04-3 0 SW - Configurator 32 bit wit h OEM-Software wit hout OEM-Software for PRIMERG Y Server for PRIMERG Y Server OEM-SW is bou nd to HW and VMw are-Software is not a llow ed to be orde red - Virtual Infrastructu re 3 Usage of OEM SW from MS i ...

  • Fujitsu PRIMERGY RX300 S5 - page 6

    System c onfigurator and or der-information guide Start PRIMER GY RX300 S5 PRIMERGY RX 300 S5 Status 2010-04-3 0 SW Configu rator EM64T wit h OEM-Software w ithout OEM-Software for PRIMERG Y Server for PRIMERG Y Server For all SW produ cts please refer to the correspo ndi ng software con figurator accessibl e via th e Extrane t un der "Con fig ...

  • Fujitsu PRIMERGY RX300 S5 - page 7

    Sy stem configurato r and orde r-information guide Start PRIMERGY RX300 S5 PRIMERGY RX300 S5 Statu s 2010-04 -30 Section I Basic unit System unit consisting of: * 2U Housing including one pow er supply module - hot plug Power suppl y uni t with 1 PSU module and power cord rack 4m le nght (can be upgraded with on e additiona l PSU module ) * Fan uni ...

  • Fujitsu PRIMERGY RX300 S5 - page 8

    Sy stem configurato r and orde r-information guide A PRIMERGY RX300 S5 Statu s 2010-04 -30 Cables included in basic unit Connections Cable PRIMERGY RX300 S5  SAS 1. SATA DVD    SATA 2. SAS cab les to HDDs   1x cable for SAS signaling   3. Pow er cable Rack version for 19'' racks with Rack version for 19'' ...

  • Fujitsu PRIMERGY RX300 S5 - page 9

    Sy stem configurato r and orde r-information guide B PRIMERGY RX300 S5 Statu s 2010-04 -30 PRIMERGY 19" Rack S26361-F2735 -E101 S26361-F2735 -E110 S26361-F2735 -E111 RMK-F1_1-2U Server RMK-P_1-2U Server No Rackmou nt-Kit option telescopic rai l, full extractio n, telescopic rai l, partial ex traction Only for loose deli veries 1-hand-mounting ...

  • Fujitsu PRIMERGY RX300 S5 - page 10

    Sy stem configurato r and orde r-information guide C PRIMERGY RX300 S5 Statu s 2010-04 -30 Section II Processor There are 2 processor sockets availab le. The first socket is alway s equipped wi th the first CPU which can be selected via configurator It is also possible to upgrad e a dual-processor sy stem later on with a second CPU Two processors w ...

  • Fujitsu PRIMERGY RX300 S5 - page 11

    Sy stem configurato r and orde r-information guide D PRIMERGY RX300 S5 Statu s 2010-04 -30 Section III Memory - There are 9 memory slots for max. 72GB DDR3 RAM per CPU available with 8GB DIMMs => max. 144GB for two CPU`s ( 72GB per CPU ) ( For explanation of followi ng terms refer to sect ion "Memory Configurations" - The memor y area ...

  • Fujitsu PRIMERGY RX300 S5 - page 12

    Sy stem configurato r and orde r-information guide PRIMERGY RX300 S5 Statu s 2010-04 -30 E1 E2 S26361-F3284 -E1 S26361-F3284 -E2 Spare Channel Mode Installation P erformance Mode Inst allation With this order code a BIOS setup With this order code BIOS setup for spare mode i s fact ory pr einstall ed is default for hig hest performance The three id ...

  • Fujitsu PRIMERGY RX300 S5 - page 13

    Sy stem configurato r and orde r-information guide PRIMERGY RX300 S5 Statu s 2010-04 -30 F1 F2 S26361-F3284 -E3 Mirrored Channel Mode Installation With this order code a BIOS setup for Mirrored Channel Mode i s factory prei nstalled The two identi cal memor y modu les of followi ng order codes are al ways equipp ed in one mem ory ban k to use the M ...

  • Fujitsu PRIMERGY RX300 S5 - page 14

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Memory Configuration PRIMERGY RX300 S5 Each CPU offers 9 Slots f or DDR3 Me mory Modules organised in 3 Banks and 3 Channels. If you need more than 9 Slots you have to configure the 2nd CPU. Depending on the amount of m emory configured you can decide betwe en 4 ...

  • Fujitsu PRIMERGY RX300 S5 - page 15

    1. Independen t Channel Mode required required if 2nd CPU is configured Bank I Data Dat a Data Data Data Data optional, same type in Bank per CPU (black sockets) Bank II Data Dat a Data Data Data Data optional, any type (blue sockets) Bank III Data Dat a Data Data Data Data ----- --- not used (green sockets) Independent Cha nnel Mode allow s all ch ...

  • Fujitsu PRIMERGY RX300 S5 - page 16

    Sy stem configurato r and orde r-information guide G PRIMERGY RX300 S5 Statu s 2010-04 -30 Section V Accessible drives Setup RX3 00 S5 by ServerStart is supported wi th followi ng configuration s: no DVD, no CD: remote in stallation on ly ( PX E service & DHCP server required) built in CD/DVD or USB CD/DVD disk drive: UNC Network share reachabl ...

  • Fujitsu PRIMERGY RX300 S5 - page 17

    Sy stem configurato r and orde r-information guide H PRIMERGY RX300 S5 Statu s 2010-04 -30 Section VI Hard disks drives Modular Raid controller is connected to internal HDDs For basic units V1xx up to 6 SAS 3.5" hard disks can be configur ed also in mi xed configura tion. If the option "Tape drive" is configured onl y 4 bay s for har ...

  • Fujitsu PRIMERGY RX300 S5 - page 18

    Sy stem configurato r and orde r-information guide H PRIMERGY RX300 S5 Statu s 2010-04 -30 Section VI SAS 6G HD's and Controller for basic units V2xx up to 8 SAS 2.5" For basic units V2xx up to 8 SAS 2.5" hard disks pl us the option "Tape drive" can be configured. Mixed configurations with SS D and SATA 2.5" HD`s are N ...

  • Fujitsu PRIMERGY RX300 S5 - page 19

    System c onfigurator and or der-information guide I PRIMERGY RX 300 S5 Status 2010-04-3 0 Section VII Modular Raid 0/1 an d Raid5 Controller S2636 1-F3257-E8 Modular Raid 0/1 co ntroller w ith IME support for SAS/SA TA-HDs 8 port SAS RAID C ontroll er IME (Integrated Mirrorin g Enh an ced) offers the RAID le vels 0, 1, 1E LSI IME is a RA ID 0, 1 im ...

  • Fujitsu PRIMERGY RX300 S5 - page 20

    System c onfigurator and or der-information guide J PRIMERGY RX 300 S5 Status 2010-04-3 0 SAS-/SC SI-/ Fibre-Channel Controller Low Profile * 2 PCIe-2 slots wi red x8 an d 5 PCIe-2 slo ts wired x4 : A PCIe-2 x4 card can al so be plu gged in a PCIe-2 x8 slot Slot 7 an d 6 are w ired x 8 a nd n otched A PCIe-2 x8 card can also be plugged i n a PCIe - ...

  • Fujitsu PRIMERGY RX300 S5 - page 21

    System c onfigurator and or der-information guide K PRIMERGY RX 300 S5 Status 2010-04-3 0 SAS RA ID controller for JBOD su bsystems S2636 1-F3890-E2 01 S2636 1-F3890-E2 30 8 port SAS RAID C ontroll er 8 port SAS RAID C ontroll er LSI LSI MegaRA ID SAS8880 E M egaRAID SAS88 80E 512M B Cache with ECC 512M B Cache with ECC iBBU max. 2x per system poss ...

  • Fujitsu PRIMERGY RX300 S5 - page 22

    System c onfigurator and or der-information guide L PRIMERGY RX 300 S5 Status 2010-04-3 0 Section VIII Communica tion / Netw ork Dual Port GBit on-board L AN Controller Teaming: Failover, Load Balancing Gigabi t Ethern et Control ler on -board The In tel LAN Co ntroll ers 1000TX an d 1000S X Dua l Port GBit LAN con trolle r can be u sed wi th th e ...

  • Fujitsu PRIMERGY RX300 S5 - page 23

    System c onfigurator and or der-information guide M PRIMERGY RX 300 S5 Status 2010-04-3 0 Section IX System Manag ement Products (RemoteView) S2636 1-F1790-E2 41 iRMC S2 advan ced pack in tegrated remote managemen t controll er activation key for graphi cal consol e redirectio n and remote media redirecti on max. 1x per system S2636 1-F1790-E2 21 R ...

  • Fujitsu PRIMERGY RX300 S5 - page 24

    System c onfigurator and or der-information guide PRIMERGY RX 300 S5 Status 2010-04-3 0 Change Report Date Order number Changes 2010-04 -06 S26361-F36 01-E160/500 new BC-SATA HD drives - now available 2009-10 -01 S26361-F32 99-E32/64 new SSD HD drives - as soon as availab le 2009-09 -01 S26361-F35 54-E/L512 New SAS Modul ar RAID Controll er 6Gb/s - ...

Produzent Fujitsu Kategorie Server

Dokumente, die wir vom Produzenten des Geräts Fujitsu PRIMERGY RX300 S5 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Fujitsu
- Bedienungsanleitungen PRIMERGY RX300 S5
- Produktkarten Fujitsu
- Informationsbroschüren
- oder Energieetiketten Fujitsu PRIMERGY RX300 S5
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Fujitsu PRIMERGY RX300 S5.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Fujitsu PRIMERGY RX300 S5, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Fujitsu PRIMERGY RX300 S5. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Fujitsu PRIMERGY RX300 S5 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Fujitsu PRIMERGY RX300 S5, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Fujitsu PRIMERGY RX300 S5 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Fujitsu PRIMERGY RX300 S5 verständlich ist.

Eine gänzliche Bedienungsanleitung von Fujitsu sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Fujitsu PRIMERGY RX300 S5 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Fujitsu PRIMERGY RX300 S5 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Fujitsu PRIMERGY RX300 S5, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Fujitsu PRIMERGY RX300 S5 - die uns die ersten Schritte während der Nutzung von Fujitsu PRIMERGY RX300 S5 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Fujitsu PRIMERGY RX300 S5 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Fujitsu PRIMERGY RX300 S5 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Fujitsu PRIMERGY RX300 S5?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Fujitsu PRIMERGY RX300 S5 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Fujitsu PRIMERGY RX300 S5 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)