  • APC 1609 - page 1

    41063-222-01 (1) 990-1868 12/2004 Inst allation and Operation 1609 Industrial Uninter r uptible P o wer Supply User Manual ...

  • APC 1609 - page 2

    3 Mount the UPS This unit is designed to mount on a h eavy duty DIN rail or on the back pane l of an enclosure. For details on DIN rail installation refer to the DIN rail installation gu ide included in the DIN rail package. The DIN rail kit is not included. When mounting on the back panel of an enclosure, select screws that are appropriate for the ...

  • APC 1609 - page 3

    4 Front Panel Connect Power and Equipment to the UPS Hardwiring should be performed by a qua lified electrician. Use appropriate size wir es. 1. The UPS features a transient voltage surge-suppression ( TVSS ) screw located on the front panel. The TVSS screw is used for connecting the ground l ead on surge suppression de vices such as telephone and ...

  • APC 1609 - page 4

    5 Connectors Communication Port Contact Closure Port Output Contact Ratings: Emergency Power Off The emergency power of f (EPO) featur e is user configurable. EPO provides immediate de-energizing of connected equipment from a remote location, without switching to battery operation. Use a normally-open contact to connect th e EPO COM terminal to the ...

  • APC 1609 - page 5

    6 Operation Operation UPS Display Panel Display Panel Indicators and Function Buttons Indicator LED Indicator Title Description On-Line The UPS is supplying utility power to the connected equipment (see T roubleshooting ). A VR T rim The UPS is compensating for a high utility voltage (see T roubleshooting ). A VR Boost The UPS is compensating for a ...

  • APC 1609 - page 6

    7 Operation Diagnostic Utility Vo l t a g e The UPS has a diagnostic feature th at indicates the utility voltage. The UPS starts a self-test as part of this procedure. The self-test does not affect the voltage display . Press and hold the button to view the utility voltage bar graph indicator . After a few seconds, this five-LED Battery Char ge ind ...

  • APC 1609 - page 7

    8 User Configurable Items User Configurable Items UPS settings Settings are adjusted through PowerChute  software or optional Network Management Card. Function Factory Default User Selectable Choices Description Automatic Self-T est Every 14 days (336 hours) • Every 7 days (168 hours) • On start up only • No self-test Set the interval at w ...

  • APC 1609 - page 8

    9 User Configurable Items Low Battery Wa r n i n g 2 minutes 2, 5, 8, 1 1, 14, 17, 20, 23 minutes PowerChute software interface provides automatic, unattended shutdown when approximately two minutes of battery operated run time remains. The low-battery warning beeps are continuous when two minutes of run time remain. Change the low battery warning ...

  • APC 1609 - page 9

    10 Storage, Maintenance, Transport Storage, Maintenance, T ransport Storage Store the UPS covered in a cool, dry lo cation with the batteries fully char ged. At 5° to 86° F (–15° to 30° C), char ge the UPS battery every six months. At 86° to 1 13° F (30° to 45° C), char ge the UPS battery every three months. Replacing the Battery Module T ...

  • APC 1609 - page 10

    11 Troubleshooting T roubleshooting Use this chart to solve minor installation and operation problems. Refer to Rockwell Automation T ech Support at 440-646-5800 for further support. Problem and/or Possible Cause Solution UPS will not turn on The battery is not connected properly . Check th at the battery connector is fully engaged. button not push ...

  • APC 1609 - page 11

    12 Troubleshooting All LEDs are off and the UPS is wired to input utility power The UPS is shut down or the battery is discharged from an extended outage. None: The UPS will restart automatically when utility power is restored and the battery has a sufficient char ge. The Overload LED is illuminated and the UPS emits a sustained alarm tone The UPS ...

  • APC 1609 - page 12

    13 Troubleshooting There is no utility power There is no utility power and the UPS is off Use the cold start feature to supply power to the connected equipment from the UPS battery(s). Press and hold the button. The unit w ill emit two beeps, one short beep and one long beep. Release the button during the second beep. UPS operates on battery althou ...

  • APC 1609 - page 13

    14 Service and Contact Information Service and Cont act Information Service If the UPS requires service do not return it to the dealer . Follow these steps: 1. Review the problems discussed in T r oubleshooting to eliminate common problems. 2. If the problem persists, contact Ro ckwell Automation Customer Support. – If the product is determined t ...

  • APC 1609 - page 14

    Safety Information - SA VE T HIS GUIDE This S afety Guide contains impor tant instructions that sho uld be fo llo we d during install ation and mainte nance of the equipme nt and batterie s. I t is intended f or custom ers w ho setup, ins tall, re locate , or maintain e quipment. Changes a nd modifica tions to thi s unit not expressl y appro ved co ...

Produzent APC Kategorie Power Supply

Dokumente, die wir vom Produzenten des Geräts APC 1609 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen APC
- Bedienungsanleitungen 1609
- Produktkarten APC
- Informationsbroschüren
- oder Energieetiketten APC 1609
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung APC 1609.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen APC 1609, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen APC 1609. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts APC 1609 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts APC 1609, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von APC 1609 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von APC 1609 verständlich ist.

Eine gänzliche Bedienungsanleitung von APC sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von APC 1609 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von APC 1609 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich APC 1609, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts APC 1609 - die uns die ersten Schritte während der Nutzung von APC 1609 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit APC 1609 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von APC 1609 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich APC 1609?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit APC 1609 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit APC 1609 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)