Bedienungsanleitung Procom QN300RYLA-W

25 Seiten 2.53 mb
Download

Zur Seite of 25

Summary
  • Procom QN300RYLA-W - page 1

    1 OWNER ’ S OPERA TION AND INST ALLA TION MANUAL COMP ACT L.P .& NA TURAL GAS VENT -FREE STOVE W ARNING: If the infor mation in this manual is not follo wed exactly,a fire or explosion may result causing prop erty damage, personal injury, or loss of life. W ARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in wh ...

  • Procom QN300RYLA-W - page 2

    2 Safety information warnings--------------------3 Air for conbustion & V entilation----------------5 Installation-------------------------------------------7 Operation Heater---------------------------- -----1 1 Cleaning and Maintenance-------------------- 13 Specification----------------------------------------15 T roubleshooting------------- ...

  • Procom QN300RYLA-W - page 3

    3 IMPORT ANT : Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. SAFETY INFORMA TION W ARNINGS DANGER: Carbon monoxide poisoning may lead to death! ...

  • Procom QN300RYLA-W - page 4

    4 SAFETY INFORMA TION Continued 15. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. 16. Operating heater above elevations of 4,500 feet could cause pilot outage. 17. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger) ...

  • Procom QN300RYLA-W - page 5

    5 AIR FOR COMBUSTION AND VENTILA TION W ARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your PROVIDING ADEQUA TE VENTI ...

  • Procom QN300RYLA-W - page 6

    6 W ARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. Y ou will need no additional fresh air ventilation. 3. Add the Bt ...

  • Procom QN300RYLA-W - page 7

    7 W A TER V APOR:A BY -PRODUCT OF UNVENTED ROOM HEA TERS Water vapor is by-product of gas combustion.an unvented room heater prodrces approximately one (1) ounce (30ml) of water for every 1, 000BTU’s (.3kw’s) of gas input per hour. Unvented room heaters are recom- mended as supplemtal heat (a room) rather that a primary heat source(an entire ho ...

  • Procom QN300RYLA-W - page 8

    8 CLEARANCES TO COMBUSTIBLES (V ent-Free Operation Only) Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORT ANT : Y ou must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top. M ...

  • Procom QN300RYLA-W - page 9

    9 W ARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas. CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2 " diameter or greater to allow proper volume gas to heater. If pipe is too small, ...

  • Procom QN300RYLA-W - page 10

    10 2. Open gas supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (LP GAS see Figure 9.1 NA TURAL GAS see Figure 9.2). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Ope ...

  • Procom QN300RYLA-W - page 11

    11 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by control system, When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the f ...

  • Procom QN300RYLA-W - page 12

    12 b. manual select of main burner: Press BURNER button, the flame is on “MAN” select. At this selection, the main burner will keep working no matter what the temperature is set at. If there is a need to shut off the main burner, just press the “BURNER” button to make the burner on the “OFF” select. c.shut off the main burner: the main ...

  • Procom QN300RYLA-W - page 13

    13 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME P A TTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut ...

  • Procom QN300RYLA-W - page 14

    14 Air Passageways  Use a vacuum cleaner or pressurized air to clean. Exterior  Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. LOGS  If you remove logs for cleaning, refer to Installing Logs to properly replace logs.  Replace logs if broken or chipped (dimesized or larger). REPLACEMENT P A ...

  • Procom QN300RYLA-W - page 15

    15 SPECIFICA TIONS QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W Btu(V ariable) Gas T ype LP Gas Natural Gas Ignition Automatic Automatic Manifold Pressure 8"W.C. 3"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 1 1" 5" Dimensions, Inches (H × W × D) Heater 25 4/5" × 32 1/4” × 13" 2 ...

  • Procom QN300RYLA-W - page 16

    16 TROUBLESHOOTING REMEDY W ARNING :Make sure that power is turn off before proceeding.... W ARNING: T urn off and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. When pressing the button of ignit ...

  • Procom QN300RYLA-W - page 17

    17 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Delayed ignition burner 1. Manifold pressure is too low 2. Burner orifice clogged 1 . Contact local gas company 2. Clean burner (see Cleaning and Maintenance, page 13) Burner backfiring during combustion 1. Damaged burner 2. Gas regulator defective 1. Clean burner orifice ( see Cle ...

  • Procom QN300RYLA-W - page 18

    18 ILLUSTRA TED P ARTS BREAKDOWN QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QN300RYLA-W - page 19

    19 P ARTS LIST QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QN300RYLA-W - page 20

    20 ILLUSTRA TED P ARTS BREAKDOWN QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QN300RYLA-W - page 21

    21 P ARTS LIST QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QN300RYLA-W - page 22

    22 PLACING INSTRUCTION Follow the procedures below and the instruction drawings to put log sets in place to the gas stove(indoor vent-free). NOTICE: THE CORRECT POSITION OF THE LOGS SHOULD NOT IM- PINGE ON THE FLAME. THE LOG’S P ACKAGE IS LOCA TED INSIDE THE UNIT THEN REMOVE SCREEN AND T AKE OUT THE LOG’S P ACKAGE FIRST REMOVE TWO TOP SCREWS FR ...

  • Procom QN300RYLA-W - page 23

    23 Q SERIES LOG SET INST ALLA TION INSTRUCTIONS ...

  • Procom QN300RYLA-W - page 24

    24 FIG(3) FIG(4) STEP 2: Install the log 2 on the right rear angle iron. see FIG(3) STEP 3: Install the log 3 on the front angle iron. See FIG(4). 1 INST ALLA TION INSTRUCTIONS FOR LOG SETS 1. All logs FIG(1) FIG(2) STEP 1: Install the log 1 on the left rear angle iron. see FIG(2) ...

  • Procom QN300RYLA-W - page 25

    25 2 2 FIG(5) STEP 4: Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1. Place the lower part of log 4 on the flat roof at the left side of log 3 See FIG(5). STEP 4: Insert the pinhole on the upper part of log 5 into the pin on the log 2. Place the lower part of log 5 on the flat roof at the left side of log 3 . S ...

Produzent Procom Kategorie Stove

Dokumente, die wir vom Produzenten des Geräts Procom QN300RYLA-W erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Procom
- Bedienungsanleitungen QN300RYLA-W
- Produktkarten Procom
- Informationsbroschüren
- oder Energieetiketten Procom QN300RYLA-W
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Procom QN300RYLA-W.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Procom QN300RYLA-W, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Procom QN300RYLA-W. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Procom QN300RYLA-W ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Procom QN300RYLA-W, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Procom QN300RYLA-W hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Procom QN300RYLA-W verständlich ist.

Eine gänzliche Bedienungsanleitung von Procom sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Procom QN300RYLA-W bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Procom QN300RYLA-W befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Procom QN300RYLA-W, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Procom QN300RYLA-W - die uns die ersten Schritte während der Nutzung von Procom QN300RYLA-W erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Procom QN300RYLA-W hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Procom QN300RYLA-W im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Procom QN300RYLA-W?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Procom QN300RYLA-W nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Procom QN300RYLA-W hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)