    ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number 1.6L 25kW Models: 005324-1 005325-1 —  CAUTION  — ONL Y QU ALIFIED ELECTRICIANS OR CONTRA CT ORS SHOULD A TTEMPT INST ALLA TION! DEADL Y EXHA UST FUMES. OUTDOOR INST ALLA TION ONL Y!   N ot i ...

  • Generac Power Systems 005324-1, 005325-1 - page 2

    Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ................................... 1-3 Operation and Maintenance ...................................... 1-3 How to Obtain Servic ...

  • Generac Power Systems 005324-1, 005325-1 - page 3

    Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental ru ...

  • Generac Power Systems 005324-1, 005325-1 - page 4

    • Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and ...

  • Generac Power Systems 005324-1, 005325-1 - page 5

    1-3 I NTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written. However , the manufacturer reserves the right to change, alter or otherwise improve this produ ...

  • Generac Power Systems 005324-1, 005325-1 - page 6

    I DENTIF ICA TION R E C OR D D A T A LA BE L Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the gen- erator’s lower connection box, lists the unit ’s serial number and its rated voltage, amps, wattage capacity , phase, frequency , rpm, power ...

  • Generac Power Systems 005324-1, 005325-1 - page 7

    E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units. See the Specifications section for exact numbers. The unit comes com ...

  • Generac Power Systems 005324-1, 005325-1 - page 8

    ENGI NE P RO TE CTIVE DEVICE S The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm. F or that reason, the engine has several devices designed to protect it against potentially damaging conditions by automatically shuttin ...

  • Generac Power Systems 005324-1, 005325-1 - page 9

    F U E L SYST E M FUE L RE QUIRE MEN T S The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing Listing that is affixed to the unit includes the “Identification Code,” which may be used to identify the type of fuel system installed on the uni ...

  • Generac Power Systems 005324-1, 005325-1 - page 10

    SP E CIF ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation .................................................................... Class F Stator Insulation ................................................................... Class F T otal Har monic Distor tion ..... ...

  • Generac Power Systems 005324-1, 005325-1 - page 11

    COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R E C ONF IGU RI NG TH E FU EL SY S TEM NOTE: All models are configured for natural gas or LP vapor from the factory . T o reconfi ...

  • Generac Power Systems 005324-1, 005325-1 - page 12

    GEN ERA T OR A C LEAD C ON NECTIONS See “V oltage Codes”. This generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s A C con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application. If there are any q ...

  • Generac Power Systems 005324-1, 005325-1 - page 13

    I NS T ALLA TION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. P REP AR A TION BEFOR E ST ART -UP The instructions in this section assume that the standby generator has been properly installed, ser - viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor . Be ...

  • Generac Power Systems 005324-1, 005325-1 - page 14

    • Battery charger connection to 120 V AC. • Communication wires connected between transfer switch and generator (HTS only). • Unit secured to pad. S T ART -U P CH E CKLIS T  Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 120V AC supply to the battery charger is swit ...

  • Generac Power Systems 005324-1, 005325-1 - page 15

    GEN ERA T OR C ONTROL AN D OP ERA TION Refer to the appropriate control panel operator’s manual for this unit. OP ERA TI NG U N IT WITH MAN U AL TR ANSFER SWIT CH If the generator was installed in conjunction with a transfer switch capable of manual operation only , the following procedure applies. A manually operated transfer switch is one that ...

  • Generac Power Systems 005324-1, 005325-1 - page 16

    MAI NTENANCE PER FOR M ED B Y SERVICE F ACI LITIES  Before working on the generator , ensure the fol- lowing: The AUTO/OFF/MANU AL switch is in the OFF position. The 15A fuse has been removed from the con- trol box. The 120V AC supply to the battery charger is switched OFF . EVER Y TH R EE MONTHS 1. Check battery condition. 2. Inspect and test f ...

  • Generac Power Systems 005324-1, 005325-1 - page 17

    Figure 10.1 - Oil Dipstick and Oil Fill Cap OIL FILL CAP OIL DIPSTICK B A TTE R Y FL UID Check battery electrolyte fluid based on the Maintenance Schedule. Fluid should cover separa- tors in all battery cells. If fluid level is low , add dis - tilled water to cover tops of separators. DO NOT USE T AP W A TER IN BA TTERY . ENGI NE COOLANT Check cool ...

  • Generac Power Systems 005324-1, 005325-1 - page 18

    CHANGI NG ENGIN E OIL Refer to maintenance performed by service facilities for engine oil and filter change frequencies. Drain the oil while the engine is still warm from run- ning . This means warm up the engine, shut it down and drain immediately as follows: 1. Remove OIL DRAIN HOSE from its retaining clip. 2. Loosen and remove OIL DRAIN HOSE CAP ...

  • Generac Power Systems 005324-1, 005325-1 - page 19

    M IS CELLAN EOUS MAINTENANCE CLEAN ING TH E GENER A T OR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance. P eriodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dr ...

  • Generac Power Systems 005324-1, 005325-1 - page 20

    SERVICE S CH EDULE The following is a recommended maintenance schedule for small standby and residential generator sets. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application. They will need to be decreased (performed more frequently) if the unit is used in a severe applica- ti ...

  • Generac Power Systems 005324-1, 005325-1 - page 21

    Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp. Required Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- monthly Initials) Break-in Initials) annually Initials) Annually Initials) 10 Hrs. 30 Hrs. 50 Hrs. 100 Hrs. 1. Disable t ...

  • Generac Power Systems 005324-1, 005325-1 - page 22

    Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp. Required Comp. to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- monthly In itials) Break-in Initials) annually Initials) Annually Initials) 10 Hrs. 30 Hrs. 50 Hrs. 100 Hrs. 13. Initiat ...

  • Generac Power Systems 005324-1, 005325-1 - page 23

    TROU BLESHOO TI NG GU IDE P ROBLEM CAUSE C OR RECTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defectiv e 2. Tighten, clean or replace batter y cables. battery cables as necessar y . 3. Defectiv e star ter contactor . 3. Replace contactor .* 4. Defectiv e star ter motor . 4. Replace star ter motor .* 5. D ...

  • Generac Power Systems 005324-1, 005325-1 - page 24

    Standby Generator Sets Notes ...

  • Generac Power Systems 005324-1, 005325-1 - page 25

    Standby Generator Sets Notes ...

  • Generac Power Systems 005324-1, 005325-1 - page 26

    Standby Generator Sets Notes ...

  • Generac Power Systems 005324-1, 005325-1 - page 27

    Standby Generator Sets Notes ...

  • Generac Power Systems 005324-1, 005325-1 - page 28

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 29

    1 0F71 35 1 BREAKE R TRAY BACK/BO TTOM 2 0F7022 1 SUPPORT CONTROL P ANEL SIDE RH 3 0F7021 1 SUPPORT CONTROL P ANEL SIDE LH 4 0F72 60 1 COVER CIRCUIT BREA KER 2P 0F71 36 1 COVER CIRC UIT BREAKER 3P 5 0F61 56 1 PLATE WIRE S NGL GALV 6 0F4 4 64 1 DE CA L CUS T CO NN 120V UTIL ITY 7 0D469 8 RE F BLOCK TERM 20 A 6 X 3 X 1100V 8 0F38 24 1 DECA L UTIL SEN ...

  • Generac Power Systems 005324-1, 005325-1 - page 30

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 31

    ROT 0RS BE LOW M UST BE VE R IFIE D BY SE RIAL NO. AND B.O .M . 1 0G29 27 1 RTR- 102-20. 0AD1 CPL (2 006) (FOR U NITS B UILT AFTER FEBRU ARY 20 07) 0G28 27 1 ASS Y RTR 25KW 2P (20 06) (FO R UNIT S B UILT AF TER FE BRUARY 200 7) 09867 5 1 AS SY RTR 20 KW 2PH (FOR U NITS B UILT BE FORE FE BRUARY 2007) 09893 6 1 AS SY RTR 25 KW 2PH (FOR U NITS B UILT ...

  • Generac Power Systems 005324-1, 005325-1 - page 32

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 33

    C O M PO N EN T S IN CL UD ED IN 0 G3 3 6 5 E 1 0F 18 2 3A 1 E N CL HS B C ON T R OL P A N EL 2 0F 3 0 7 8 1 C OV ER C O N TR O L PA N E L 3 0F 2 6 0 6 1 H IN G E C O N T IN U OU S H - P A N E L 4 03 6 26 1 6 R IV E T P O P .1 2 5 X .2 7 5 S S 5 0 E 7 3 5 8 4 S C RE W P PP H H I- L O #4 -24 X 3 /8 6 05 2 77 7 3 W A S H ER F LA T M 3 7 0G 13 0 3 D 1 ...

  • Generac Power Systems 005324-1, 005325-1 - page 34

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 35

    1 0F7211 1 SUPPORT R AD IATOR LH SIDE 2 0G07 60 1 VENTU RI 16" DIA F AN 3 0F7210 1 SUPPORT R ADIATOR RH SIDE 4 0E98 37B 1 RADI ATOR 1.6 L CHY 5 0F0230 B 1 FAN COOL 16" DI A 8 BLA DE 6 04652 6 5 WASHE R LO CK M10 7 0G0910 1 LOWE R RA DIATO R HOSE 1. 6 L 8 09 95 02 4 CLA M P HO S E #24 B1 .0 6- 2 .0 0 11 0G 0908 1 UP PER RA DIATOR HOSE 1 .6 ...

  • Generac Power Systems 005324-1, 005325-1 - page 36

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 37

    1 0F34 08B 1 BATT ERY TRAY C1 CPL 2 0F34 11 1 STRAP BA TTERY RET AINME NT 3 02 5507 1 WASHE R SH AKEPRO OF EX T 7/1 6 STL 4 05 9980 1 SCREW HHC M 10-1. 5 X 25 G10. 9 5 0465 26 1 WASH ER LO CK M1 0 6 07748 3 REF BATTE RY 12V DC 75- AH 26 7 0503 31A 1 BAT TERY POS T COVE R RED + 8 0503 31 1 BAT TERY POS T COVE R BLK - 9 03 88 0 5J 1 CABLE BAT T ERY B ...

  • Generac Power Systems 005324-1, 005325-1 - page 38

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 39

    1 0G075 9 1 MOUN TI N G BAS E 1. 6L 2 0 27 482 2 WASHER SHAK EPROOF EXT 5/ 16 STL 3 07093 6 2 DAMPE NER VI BRATIO N 4 070936 C 2 VIB. ISO. 70 -75 D URO 5 0392 5 3 8 SCRE W HH C M8-1. 2 5 X 20 G 8.8 6 0221 45 12 WAS HER FL AT 5/16 ZI NC 7 0221 29 12 WAS HER LO CK M 8-5/16 8 0457 71 4 NUT HE X M8- 1.25 G 8 YEL C HR 90 7 1 9 5 6 4 W A S H E R F L A T ...

  • Generac Power Systems 005324-1, 005325-1 - page 40

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 41

    1 098 290 1 ASM MOTOR STEPPER 2 09894 1A 1 HOUSING GOVERNOR CON NECTOR 3 09 8958A REF CON NECTO R INTE RFACE ASSEM BLY 4 09 89 4 2A 1 COVE R CO NNE CTO R HOUS I NG 5 098225 2 S CREW FHM #2 X 5/ 8 SELF TAP 6 0431 46 3 SCREW HHC M 6-1. 0 X 1 0 G8. 8 7 0220 97 5 WASHE R LO CK M6- 1/4 8 084543A 1 SCREW PHM M3-0.5 X 12MM 9 098783 1 LEVER STEPPER MOTOR 1 ...

  • Generac Power Systems 005324-1, 005325-1 - page 42

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 43

    1 0G0207 REF ENGINE GE NERAC 1. 6L NG 2 0G0834 1 E NGINE PLATE 1.6L 3 0G0820 REF HOUSING BLOWER MACHI NED 1.6L 4 0E9747 1 STARTE R 12 VOLT 5 0G0839 2 E NGINE MOUNTING FOOT STAMPING 6 0G0781 1 E XHAUST MANIFOL D 1.6L MACHINED 7 0G0722 1 IN TAKE MANIFOLD MACHINED 1.6L 8 0G0758 1 H EAT SHIELD LOW ER 1.6L 9 0G0431 1 H EAT SHIELD UPPE R 1.6L 10 0G0663 1 ...

  • Generac Power Systems 005324-1, 005325-1 - page 44

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 45

    1 02681 2 2 EL BO W 9 0D 3/4 NP T 2 07558 0 1 FLANGE F UEL INLE T 3 0G1397 1 FUE L RE G U LATO R 1. 6L RE W O R K 4 0392 53 2 S CREW HH C M 8-1.2 5 X 20 G 8.8 5 0221 45 2 WA SHER FL AT 5/ 16 ZI NC 6 0221 29 4 WA SHER LO CK M 8-5/ 16 7 0457 71 2 NUT HEX M 8-1. 25 G 8 YEL C HR (1) 8 0F157 0 1 BODY CARBURETOR ASSEMBLY 9 0A63 44 1 BAR BED E L 90 1 /8 N ...

  • Generac Power Systems 005324-1, 005325-1 - page 46

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 47

    1 0F 700 3 (XX) 1 ROO F C 1 CPL 2 0F 7004 ( XX) 1 COR NER P OST L H SIDE C1 CPL 3 0F 7008 ( XX) 1 DOO R REA R C1 CPL 4 0F 7005 ( XX) 1 COR NER P OST RH SIDE C1 CP L 5 0F 7007 ( XX) 2 DOO R LH & RH S IDE C1 CPL 6 0F 7006 ( XX) 1 DUC T FRO NT DIS CHARGE C 1 CPL 7 0C26 34A 1 ASS EMBLY COVER ACCE SS 8 091297 0091 1 ASSY WIR E 14 AW G 13.8 " GR ...

  • Generac Power Systems 005324-1, 005325-1 - page 48

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 49

    1 0F73 66 1 MUF FLER C1 2 0F76 47 1 MUFFL ER SA DDLE 3 0F8095 1 PIPE EXHAUST OUTLET 4 0F75 38 1 PIPE EXH I NLET M UFLR S IDE 1.5L 5 0E 3257 4 SCREW HWHTF M 6-1.0 X 16 6 0F76 44 2 MUF FLER STR AP 7 0C 6119 1 BOLT U 5/ 16-18 X 2-1 /4 8 03 6434 3 BOLT U 5/16- 18 X 2.09 9 03644 9 3 SADD LE 2 I NCH 10 022129 6 WASHE R LO CK M8- 5/16 11 022259 6 NUT HEX ...

  • Generac Power Systems 005324-1, 005325-1 - page 50

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 51

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 52

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 53

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 54

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 55

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 56

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 57

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 58

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 59

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 60

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 61

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 62

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 63

    ...

  • Generac Power Systems 005324-1, 005325-1 - page 64

    Standby Generator Sets W arranty Printed in U.S.A. GENERA C PO WER SYSTEMS ST ANDARD LIMITED W ARRANTY FOR HOME ST ANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELO W For a period of two (2) y ears from the date of sale, or start-up by A uthorized/Cer tified Generac P ower Systems Dealer , or branch thereof , Generac P ow er Systems, Inc. will, at its o ...

Produzent Generac Power Systems Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts Generac Power Systems 005324-1, 005325-1 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Generac Power Systems
- Bedienungsanleitungen 005324-1, 005325-1
- Produktkarten Generac Power Systems
- Informationsbroschüren
- oder Energieetiketten Generac Power Systems 005324-1, 005325-1
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Generac Power Systems 005324-1, 005325-1.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Generac Power Systems 005324-1, 005325-1, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Generac Power Systems 005324-1, 005325-1. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Generac Power Systems 005324-1, 005325-1 ansehen.

Die komplette Bedienungsanleitung des Geräts Generac Power Systems 005324-1, 005325-1, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Generac Power Systems 005324-1, 005325-1 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Generac Power Systems 005324-1, 005325-1 verständlich ist.

Eine gänzliche Bedienungsanleitung von Generac Power Systems sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Generac Power Systems 005324-1, 005325-1 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Generac Power Systems 005324-1, 005325-1 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Generac Power Systems 005324-1, 005325-1, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Generac Power Systems 005324-1, 005325-1 - die uns die ersten Schritte während der Nutzung von Generac Power Systems 005324-1, 005325-1 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Generac Power Systems 005324-1, 005325-1 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Generac Power Systems 005324-1, 005325-1 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Generac Power Systems 005324-1, 005325-1?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Generac Power Systems 005324-1, 005325-1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Generac Power Systems 005324-1, 005325-1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)