    238-47969-00A REV 6/09 DIRECT VENT GAS WATER HEATER WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call y our gas supplier from a neighbor’s phone. Follow the gas supplier's instructions. • If you cannot reach y our gas suppli ...

  • Honeywell 238-47969-00A - page 2

    2 CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today! This installation, operation and instruction manual will explain in detail the installation and maintenance of your new Direct Vent Gas Water Heater. We strongly recommend that you contact a plumbing professional for the installation of this water heater ...

  • Honeywell 238-47969-00A - page 3

    3 TABLE OF CONTENTS page GENERAL INFORM ATION ......................................................................... 4 INSTALLATI ON ........................................................................................ 5 Locating The Wate r Heater .................................................................... 5 Minimum Clear ances ..... ...

  • Honeywell 238-47969-00A - page 4

    4 WARNING Incorrect operation of this appliance may create a hazard to life and property and will nullify the w arranty. DANGER Do not store or use gasoline or other flammable, combustible, or corrosive vapors and liquids in the v icinity of this or any other appliance. GENERAL INFORMATION This gas-fired water heater’s design is certified by CSA ...

  • Honeywell 238-47969-00A - page 5

    5 IMPORTANT Before proceeding, please inspect the water heater and its components for possible damage. DO NOT install any damaged components. If damage is evident then please contac t the supplier where the water heater was purchased or the manufactu rer listed on the rating plate for replacement parts. WARNING Water heaters are heat producing appl ...

  • Honeywell 238-47969-00A - page 6

    6 Installation (Locating The Water Heater) continued - The location of this water heater is of the utmost importance. Before installing this water heater read the Inst allation section of these instructions. After reading these Installation and Operating Instructions, select a location for the water heater where the floor is level and is easily acc ...

  • Honeywell 238-47969-00A - page 7

    7 WARNING Liquefied petroleum gases/propane gas are heavier than air and will remain at floor level if there is a l eak. Basements, crawl spaces, closets and areas below ground level will serve as pockets for accumulation of leaking gas. Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor. IF YOU SMELL G ...

  • Honeywell 238-47969-00A - page 8

    8 WARNING Failure to adhere to these installation and operating instructions may create a hazard to life and property and will nullify the warranty. Installation (Locating The Water Heater) continue d- The water heater must be located close enough to the outside wall to keep the venting distance within the maximu m distance described in the vent ki ...

  • Honeywell 238-47969-00A - page 9

    9 WARNING The direct vent-air intake terminal is HOT while the water heater is in operation. Do not touch. Keep children, combustibles, gasoline and other liquids having flammable vapors away. OPTIONAL DIRECT VENT-AIR INTAKE TERMINAL GUARD It is recommended that a vent-air intake terminal guard be installed when the vent-air intake terminal is loca ...

  • Honeywell 238-47969-00A - page 10

    10 Installation continued- Figure 2 Figure 3 ...

  • Honeywell 238-47969-00A - page 11

    11 WARNING The vent-air intake system must be pr operly installed. Failure to properly install the vent-air intake system could result in property damage, personal injury or death. DO NOT install any damaged vent-air intake system components. Contact the manufacturer of the water heater for replacement parts. VENTING This is a Direct Vent Gas Water ...

  • Honeywell 238-47969-00A - page 12

    12 Figure 4 Direct Vent Terminal Clearances Canadian Installations1 US Installations2 A= Clearance above grade, veranda, porch, deck or balcony 12 inches (30 m) 12 inches (30 cm) B= Clearance to widow or door that may be opened 12 inches (30 m) 9 inches (23 cm) for appliances > 10,000 Btuh (3 kW) and ≤ 50,000 Btuh (15 kW), 12 inches (30 cm) fo ...

  • Honeywell 238-47969-00A - page 13

    13 Venting continued- 1 In accordance with the current CAN/CGA-B149 Installation Codes . 2 In accordance with the current AN SI Z223.1-(Latest edition)/NFPA 54 National Fuel Gas Code . † A vent must not terminate directly abov e a sidewalk or paved driv eway that is located between tw o single- family dwellings and serv es both dwellings. ‡ Per ...

  • Honeywell 238-47969-00A - page 14

    14 WATER CONNECTIONS Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while making the water connections to the water heater. After the pressure has been relieved, close the f ...

  • Honeywell 238-47969-00A - page 15

    15 Water Connections continue d- WARNING For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of produc ...

  • Honeywell 238-47969-00A - page 16

    16 Water Connections continue d- If this water heater is installed in a closed water supply system, such as the one having a back-flow preventer in the cold water supply, provisions must be made to control thermal expansion. DO NOT operate this water heater in a closed system without provisions fo r controlling thermal expansion. Your water supplie ...

  • Honeywell 238-47969-00A - page 17

    17 Gas Connections The gas supply lines must meet all requi rements of the National Fuel Gas Code (ANSI Z223.1-Latest Edition), or in Canada CAN/CGA B149.1 Natural Gas Installation Code (Latest Edition) or CAN/CGA B149.2 Propane Installation Code (Latest Edition). The minimum permissible gas supply pressure for the purpose of input adjustment is on ...

  • Honeywell 238-47969-00A - page 18

    18 GENERAL OPERATION TO FILL THE WATER HEATER 1. Close the water heater drain va lve by turning the knob clockwise . 2. Open the cold water supply shut-off valve. 3. Open several hot water faucets to allow air to escape from the system. 4. When a steady stream of water flow s from the faucets, the water heater is filled. Close the faucets and c hec ...

  • Honeywell 238-47969-00A - page 19

    19 Lighting & Shutdown Instructions – White Rodgers and Robertshaw gas control. ...

  • Honeywell 238-47969-00A - page 20

    20 Lighting & Shutdown Instructions Continued - Honeywell gas control. ...

  • Honeywell 238-47969-00A - page 21

    21 THERMOSTAT ADJUSTMENT - White Rodgers gas c ontrol. 160°F Control 180°F Control Figure 5 The thermostat dial is set to its lowest tem perature setting when shipped from the factory. Remember that lower temperature settings are more energy efficient . Adjust the temperature by turning the thermostat dial. It is suggested that the starting point ...

  • Honeywell 238-47969-00A - page 22

    22 Thermostat A djusting continued – Honeywell control. ...

  • Honeywell 238-47969-00A - page 23

    23 Thermostat Adjusting continue d- BURNER FLAME CHECKS At the time of installation and at peri odic intervals (not more than six (6) months), a visual check of the p ilot and main burner flames should be conducted. The flames should be similar to those pictured below. The main burner should light smoothly from the pilot. (See Figure 9). Figure 9 D ...

  • Honeywell 238-47969-00A - page 24

    24 MAINTENANCE The following maintenance should be performed by a qualified service technician at the minimum periodic intervals suggested below. In some installations the maintenance interval may be more frequent depending on upon the amount of use and the operating conditions of the water heater. Regular inspection and maintenance of the water he ...

  • Honeywell 238-47969-00A - page 25

    25 Maintenance c ontinued- 6. Annually remove the inner door and main burner assembly to clean orifices and related parts of any dirt or other foreign material. Inspect the burner ports for obstructions or debr is and clean with a wire brush as needed. Wire brush and/or vacuum clean the combustion chamber as needed to remove scale deposits and debr ...

  • Honeywell 238-47969-00A - page 26

    26 Maintenance c ontinued- Contact your supplier or plumbing professional for replacement parts or contact the company at the address gi ven on the rating plate of the water heater. Provide the part name, model and seri al numbers of the water heater when ordering parts. READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH OF TIME THAT PARTS AND ...

  • Honeywell 238-47969-00A - page 27

    27 DIAGNOSTICS FOR HONEYWELL CONTROL LED Status Control Status Probable Cause None (LED not on or flashing) Millivolt power is not present. Light pilot. 1. Gas valve is functioning normally 2. Gas valve is not powered. Light pilot One flash and three second pause. If set point knob is in "PILOT" position then pilot flame is detected. (no ...

  • Honeywell 238-47969-00A - page 28

    28 Diagnostics for Honeywell Control Continue d- LED Status Control Status Probable Cause Six flashes and three second pause Water leak detected by accessory module (some models). 1. Excessive amount of water in drain pan/water dam. Seven flashes and three second pause. Gas valve electronic fault detected. 1. Verify control is not w et or physicall ...

  • Honeywell 238-47969-00A - page 29

    29 DIRECT VENT WATER HEATER PARTS LIST Note: Provide the part name, model and serial numbers of the water heater when ordering parts. PART NAME & DESCRIPTION 1. Plenum 2. Plenum Gasket 3. Flue reducer 4. Dip Tube & Nipple 5. Anode Rod & Nipple 6. Temperature-Pressure Relief Valve (Certain Models) 7. Baffle 8. Vertical Radshield 9. Horiz ...

  • Honeywell 238-47969-00A - page 30

    30 THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING 1. All piping components connected to th is water heater for space heating applications must be suitable for use with potable water. In Massachusetts, space heating piping length must not exceed 50 feet. 2. Toxic chemicals ...

  • Honeywell 238-47969-00A - page 31

    31 NOTES ...

  • Honeywell 238-47969-00A - page 32

    32 NOTES ...

Produzent Honeywell Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Honeywell 238-47969-00A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Honeywell
- Bedienungsanleitungen 238-47969-00A
- Produktkarten Honeywell
- Informationsbroschüren
- oder Energieetiketten Honeywell 238-47969-00A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Honeywell 238-47969-00A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Honeywell 238-47969-00A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Honeywell 238-47969-00A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Honeywell 238-47969-00A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Honeywell 238-47969-00A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Honeywell 238-47969-00A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Honeywell 238-47969-00A verständlich ist.

Eine gänzliche Bedienungsanleitung von Honeywell sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Honeywell 238-47969-00A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Honeywell 238-47969-00A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Honeywell 238-47969-00A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Honeywell 238-47969-00A - die uns die ersten Schritte während der Nutzung von Honeywell 238-47969-00A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Honeywell 238-47969-00A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Honeywell 238-47969-00A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Honeywell 238-47969-00A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Honeywell 238-47969-00A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Honeywell 238-47969-00A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)