Windsor D250 - page 1
Read these instructi ons befor e operatin g the m achine MODEL: D250 (115V) D250IE ( 230V) Prior to Ser ial No. 100 0054536 98637 04/25/02 F CARPET EXTRAC TOR Operati ng I nstru ctio ns (E NG ) ...
-
Windsor D250 - page 2
SAFETY INS TRUCTIONS D-250 98637 01/19/ 99 2 IMPORT ANT SA FETY INSTRUCTIONS When using an el ectrical ap pliance, bas ic precauti on must alw a y s be follow ed, including the foll owing: READ ALL INSTRUCTIONS BEFORE USING THIS M ACHINE. This machine i s for commerci al use. To reduce the risk of fire, electric shock , or injury : Connect to a pro ...
-
Windsor D250 - page 3
GROUN DING INST RUCTI ONS D-250 98637 04/25/ 02 3 THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: The amp, hertz, and v oltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors. GROUNDI NG INSTRUCTIO NS: This appliance must be gr ounded. I ...
-
Windsor D250 - page 4
OPERATIONS D-250 98637 0 1/15/99 4 CA RPET INSPECTION: Determin e precis ely w hat areas y ou are going to clean. Not e problem are as in the carpet or tack strip. L ook for loose car pet, heavil y damag ed areas, discolore d stains, or grease sp ots that will require p respottin g. Note the carpet type. Check the a vailab ility of hot w a ter, dra ...
-
Windsor D250 - page 5
OPERATIONS D-250 98637 01/19/99 5 EQUIPMENT SET-U P: 1.) Pl ug pow er cable fro m machi ne into properly grounded wal l outlet. 2.) Tur n vacuum motor sw itch on and off to make s ure there i s electrical p ower at machine. 3.) Connec t vac hose to machi ne. Sl ide the swiv el cuff over the ou tlet on the tank. 4.) Connec t the hose set t o the mac ...
-
Windsor D250 - page 6
MAINTENANCE D-250 98637 0 1/19/99 6 DAILY MAINTENANCE: (At t h e end of each working d ay) : 1.) Flush the e n tire system, incl uding floor tool, ha nd tool, etc., w ith 1 to 3 gall ons of clean , hot water. 2.) Vacuum out the solution t ank . 3.) Rinse tank w ith fresh water . Periodi cally inspect the r ecovery tank an d decont aminate i f neces ...
-
Windsor D250 - page 7
MAINTENANCE D-250 98637 06/19/00 7 W A RNING: ONLY QUA LIFIED MA INTE NANC E PERS ONNE L AR E T O PERFOR M THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEME NT 1. Turn off all switches and unplu g machine. 2. R emove recov ery tan k . 3. Locate the vacuum mot or wires and disconnect at the connect or. 4. Remove the vacuum mo tor. 5. Reverse process ...
-
Windsor D250 - page 8
MAINTENANCE & TROUBLESHOOTING D-250 98637 1/15/99 8 D-250 PUM P MAINTENA NCE Per manufacturer’s recommendations the following maintenance should b e performed utilizing noted kits: 1.) 500 hours-Kit 55250751 r eplaces the V-packing, wave washer, packing spr eader and plunger guide. 2.) 500 hours-Kit 55250753 r eplaces the CAM bearing and inse ...
-
Windsor D250 - page 9
TROUBLESHOOTING CONT. D-250 98637 06/19/00 9 Solution hos e Corrosion on fitt ings Clean with steel woo l. fitting har d to Soak in ac etic ac id ( white v inegar). connect Lubricat e lig htl y with silicone base lubric ant. Carpet not Severe s oil co nditi ons Make s everal pas ses at right a ngles to getting c lean. other. Us e a prespr a y. Carp ...
-
Windsor D250 - page 10
115V WIRING DIAGRA M D-250 98637 11/07/00 10 ...
-
Windsor D250 - page 11
230V WIRING DIAGRAM D250 98637 06/19/00 11 ...
-
Windsor D250 - page 12
D250 98637 06/19/00 12 THIS PAGE LEFT BLANK INTENTIONALLY ...
-
Windsor D250 - page 13
RECOVERY TANK ASSEMBLY D-250 986 37 11/ 07/00 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 16 16 20 21 22 23 24 25 26 27 28 29 30 16 31 32 16 19AB 33 34 35 36 ...
-
Windsor D250 - page 14
RECOVERY TANK ASSEMBLY D-250 986 37 11/ 07/00 14 REF PART NO. QTY DESCRIPTION SERIAL NO. FROM NOT ES: 1 05151 1 TUBE A SM, RECO VERY T ANK 2 500009 1 LABEL, W ARNING 3 260-64A 1 ACCESS COV ER CLEAR 6 ” W /RIM 4 70546 6 SCR, 8 X 3/4 PFHT /S BL K ZINC 5 090-12A 1 FLOAT CAGE AS SY COMP LET E SLIP 6 240-46 1 FLOAT SCREEN ADAPT ER 30 D EGRE E 7 300-08 ...
-
Windsor D250 - page 15
SOLUTI ON TANK ASSE MBLY D-250 986 37 11/ 07/00 15 1AB 2 3 4 5 6 7 8 9 10 11 8 12A 13 14 15 16 17 18 19 20 21 22 23 24 25 26A 27 29 30 31 32 33 34 36 35 37 38 8 39 40 41 42 43 44 45 46 47 48 49 50 51 38 8 46 52 53 54 8 38 55 56 57 58 38 59 8 38 60 61 62 63 64 65 66 63 67 68 41 69 70 230V 15 21 20 16 17 24 23 31 12B 13 14 27 26B 25 30 29 28 28 ...
-
Windsor D250 - page 16
SOLUTI ON TANK ASSE MBLY D-250 986 37 11/ 07/00 16 REF PART NO. Q TY DESCRIPTION SERIAL NO . FROM NOT ES: 1A 360-04A 1 VACUUM 110V TW O STAG E 116392-0 1B 360-06 1 VAC UUM 116 213 220V SM 2 STG 2 05152 1 T UBE A SM, VAC EX HAU ST 3 50009 1 PAN HD SH MT L SCREW 10 X 1/2 SS 4 88208 1 W IRE, 21” GRN/14 76001 X 760 10 5 87016 1 W ASHER, #10 LOCK EXT ...
-
Windsor D250 - page 17
SOLUTI ON TANK ASSE MBLY CONT'. D-250 986 37 06/ 19/00 17 REF PART NO. Q TY DESCRIPTION SERIAL NO . FROM NOT ES: 51 065-28A 1 PLAT E, PUMP MOUNT 52 40013 1 HOSE BARB, 3/8 MPT X 1/2 D L 53 31026 3 EL BOW , 3/8NPT ST REET 54 70232 2 SCR, 10- 32 X 3/8 PPHM S SS 55 57196 2 NUT, 1/2 PU SH-ON DO ME C AP 56 040-06 1 W HEEL 8” BLK CENT ER ED HUB 57 ...
-
Windsor D250 - page 18
SUGGES TED SPARE PA RTS D-250 98637 06/19/00 18 SUGGESTED SPA R E PAR TS DESCRIPTIO N PA R T NUMBER PAGE/REF FUSE 55100041 15/2 03 BPR KIT 55250331 15/191 THERMO STAT 5513 0149 THERMO STAT 5513 0143 KIT, PAC KING PUMP 55250751 KIT, BE ARING PUM P 55250752 KIT, VAL VE PU MP 55250753 CARBON BR USHE S, VAC M OT OR 115V 140370 VAC MOT OR ASM , 115V UPP ...
-
Windsor D250 - page 19
ã 1999 Winds or Industri es, Inc. All rights reserv ed. REVISED 0 3 / 24/99 LIMITED WARRANTY Windsor Indu stries, Inc. warrant s new machine s against defects in material and workman ship under normal use and service to the original purch aser. The w arranty period i s subject t o the conditions sta ted below. 3 YEARS FOR PARTS AND 1 Y E AR FOR SE ...