Westinghouse UL-ES-VectorElite-WH09 - page 1
UL-ES-V ectorElite-WH09 OWNER'S MANUAL MANUAL DEL USUARIO MR V ector Elite TM Please write model number here for future reference: / Por favor , incluya el número del modelo aquí para futura referencia: Net W eight: 13.00 LBS Peso Neto: 5.9 KGS ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 2
2 UL-ES-V ectorElite-WH09 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFP A 70-1999), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer . If you have any questions contact the manufacturer . 3. After makin ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 3
3 UL-ES-V ectorElite-WH09 1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70-1999), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante. 3. Des ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 4
4 UL-ES-V ectorElite-WH09 FEA TURES CARACTERÍSTICAS DOWNROD INST ALLA TION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLA TION INST ALACIÓN PARA CIELORRASOS ABOVEDADOS May require a longer downrod (sold separately) Podría requerir una varilla vertical más larga (se vende por separad ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 5
5 UL-ES-V ectorElite-WH09 Unpack and inspect fan carefully to be certain all contents are included. T urn off power at fuse box to avoid possible electrical shock. 1 Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structur ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 6
6 UL-ES-V ectorElite-WH09 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 3 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remove) th e s cr ew s in th e ma ti ng s lo ts ( 2) on th e c an op y . Rotate the mounting bracket counter-clockwise and remove from the canopy . Quite l ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 7
7 UL-ES-V ectorElite-WH09 Install blade to blade bracket using three blade screws as shown. Instale el aspa a la abrazadera para aspa usando tres tornillos para aspa como se muestra. 5 BLADE INST ALLA TION INST ALACIÓN DE LAS P ALET AS MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE Install mounting bracket to outlet box in ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 8
8 UL-ES-V ectorElite-WH09 7 Choose a MOUNTING OPTION Elija una OPCIÓN DE MONT AJE FLUSH MOUNT OPTION If flush mount option is selected, proceed to page 9, step 8. OPCIÓN DE INST ALACIÓN AL RAS Si elige la opción de montaje al ras, proceda a la página 9, paso 8. NORMAL DOWNROD OPTION If installing downrod supplied with fan, proceed to page 10, ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 9
9 9 UL-ES-V ectorElite-WH09 FLUSH MOUNT OPTION OPCIÓN DE INST ALACIÓN AL RAS 8 G ui d e m ot or wi r es t hr ou gh th e ba se of th e ca no py as s ho wn an d a t ta ch ca no py directly to top of motor housing with flush mount screws and lock washers provided. Tighten screws securely . D es l ic e l os ca b le s de l m o to r a tr av és de l a ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 10
10 UL-ES-V ectorElite-WH09 10 2 1 3 F ee d mo to r le ad wi re s t hr ou gh d ow nr od /c an o py as se mb ly an d in se rt do wn ro d in to do wn ro d y ok e. M ak e su re t o a li gn ho le in d ow nr od wi t h t he ho le i n d ow nr od yo ke . In st al l y ok e c r os s pi n ( 1 ) t hr ou gh yo ke a nd do wn ro d. In s er t cl am p pi n ( 2) in t ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 11
11 UL-ES-V ectorElite-WH09 EXTENDED DOWNROD OPTION OPCIÓN CON V ARILLA VER TICAL MÁS LARGA 12 S li d e d ow nr od b al l (1 ) o f f o f d ow nr od an d re mo ve pi n (2 ). D es l ic e l a es fe ra d e la va ri ll a v er ti ca l (1 ) h as ta s ep a ra rl a d e l a va ri ll a v e rt ic al y q u it e el pa s ad or (2 ). 2 1 13 Re-install pin into ex ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 12
12 UL-ES-V ectorElite-WH09 14 F ee d mo to r le ad wi re s t hr ou gh d ow nr od /c an o py as se mb ly an d in se rt do wn ro d in to do wn ro d y ok e. M ak e s ur e t o al ig n h ol e in do wn ro d w it h th e h ol e i n do wn ro d y ok e. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps int ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 13
13 UL-ES-V ectorElite-WH09 MOUNTING MONT AJE 16 W it h br ac ke t h o ld i ng fa n as se mb l y , m a ke el ec tr ic al co nn ec ti on s u s in g th e following step for wiring instructions. C on l a pi ez a d e m on ta je su j et an do el c on j un to de l v e nt i la do r , h ag a la s c on e xi on es el éc tr ic as de ac u er do a la s s ig ui ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 14
14 UL-ES-V ectorElite-WH09 WIRING OPTIONS OPCIÓN DE CABLEADO 18 White (common) Black (hot) Blue* (hot) Main (ground) White (common) Fan Switch (hot) Light Switch (hot) Green (ground) From Fan: From House: (connect) (connect) (connect) (connect) *Attach blue wire only if attaching light kit with fan. Wall Control Follow diagram above to make wiring ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 15
15 UL-ES-V ectorElite-WH09 SECURE TO CEILING ASEGURE EL VENTILADOR AL CIELORRASO The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy , allowing the two screws and star wahers to slide into the mating slots. Rotate the cano ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 16
16 UL-ES-V ectorElite-WH09 LIGHT FIXTURE INST ALLA TION INST ALACIÓN DEL AR TEF ACTO LUMINOSO Remove the spot head cover ring by twisting counterclockwise. Save it for later use. Quite el anillo de la cubierta de la lámpara direccional girando en sentido contrahorario. Guárdela para usarla más tarde. 20 21 Install light bulbs. Instale las bombi ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 17
17 UL-ES-V ectorElite-WH09 Line up the "L" slot (1) with the dent on spot head (2), push the cover into the spot head and twist the cover clockwise. Alinee la ranura en forma de “L” (1) con la marca en el alojamiento de la lámpara direccional (2), empuje la cubierta hacia el interior del alojamiento de la lámpara direccional y gire ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 18
18 UL-ES-V ectorElite-WH09 Operation T urn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls directi ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 19
19 UL-ES-V ectorElite-WH09 Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habi ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 20
20 UL-ES-V ectorElite-WH09 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly , installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, p ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 21
21 UL-ES-V ectorElite-WH09 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar prob ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 22
22 UL-ES-V ectorElite-WH09 ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 23
23 UL-ES-V ectorElite-WH09 # Description 1 . . . . . . . . . . . . . . . . . . Mounting Bracket 2 . . . . . . . . . . . . . . . . . . Blade Bracket 3 . . . . . . . . . . . . . . . . . . Blade 4 . . . . . . . . . . . . . . . . . . Fan Speed Switch 5 . . . . . . . . . . . . . . . . . . Light Control Switch 6 . . . . . . . . . . . . . . . . . . Capaci ...
-
Westinghouse UL-ES-VectorElite-WH09 - page 24
UL-ES-V ectorElite-WH09 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia, PA 19154 U.S.A. Westinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee is a registered trademark of Westinghouse Electric Corporation Made in China © 2009 Westinghouse Lighting Corporation Westinghouse Lighting Corporation 12401 McNu ...
Haben Sie eine Frage bezüglich Westinghouse UL-ES-VectorElite-WH09?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Westinghouse UL-ES-VectorElite-WH09 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Westinghouse UL-ES-VectorElite-WH09 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.