USER MANUAL MODELS 2113 & 2115 CopperLink™-T T1/E1 Extender s SALES OFFICE (301) 975-1000 TECHNICAL SUPPOR T (301) 975-1007 P ar t# 07M2113-UM Doc# 03331U2-001, Rev . B Revised 8/16/07 An ISO-9001Cer tified Company Important —This is a Class A device and is intended for use in a light industrial environ- ment. It is not intended nor approv ...
-
Patton electronic 2115 - page 2
2 CONTENTS 1.0 Warranty Information ................................................................. 3 1.1 Radio and TV Interference ............................................................ 3 1.2 CE Declaration of Conformity ....................................................... 3 1.3 Authorized European Representative ....................... ...
-
Patton electronic 2115 - page 3
3 1.0 W ARRANTY INFORMATION P atton Electronics warrants all Model 2113 or 2115 components to be free from def ects, and will—at our option—repair or replace the product should it f ail within one year from the first date of the shipment. This warranty is limited to def ects in w orkmanship or mater ials, and does not cov er customer damage, a ...
-
Patton electronic 2115 - page 4
4 The saf ety advice in the documentation accompan ying this product shall be obey ed. The conformity to the abov e directive is indicated b y the CE sign on the de vice. 1.3 AUTHORIZED EUR OPEAN REPR ESENTATIVE D R M Green, European Compliance Ser vices Limited. Oakdene House, Oak Road , W atchfield, Swindon, Wilts SN6 8TD , UK 1.4 FCC PART 68 Th ...
-
Patton electronic 2115 - page 5
5 registration was perf or med based on a Declaration of Conf or mity indicat- ing that Industr y Canada technical specifications were met. It does not imply that Industr y Canada approv ed the equipment. This Declaration of Conf or mity means that the equipment meets cer tain telecommunications network protectiv e, operational and saf ety require ...
-
Patton electronic 2115 - page 6
6 1.6 COMPLIANCE EMC • FCC P ar t 15, Class A • EN55022, Class A • EN55024 Safety • UL 60950-1/CSA C22.2 N0. 60950-1 • IEC/EN60950-1 • AS/NZS 60950-1 PSTN Regulatory • FCC P ar t 68 • CS03 • TBR12 & 13 • AS/A CIF S016:2001 • AS/A CIF S043:2003 1.7 SERVICE All warranty and non-w arranty repairs must be retur ned freight pre ...
-
Patton electronic 2115 - page 7
7 Alternate P atton support for Europe, Middle East, and Africa (EMEA) • T elephone suppor t: Standard telephone suppor t is a vailable fiv e days a week—from 8:00 am to 5:00 pm CET ( 0900 to 1800 UTC/GMT )— by calling +41 (0)31 985 25 55 • F ax: +41 (0)31 985 25 26 1.8 SAFETY WHEN W ORKING WITH ELECTRICITY • This device contains no user ...
-
Patton electronic 2115 - page 8
8 2.0 GENERAL INFORMATION Thank you purchasing this P atton Electronics product. This product has been thoroughly inspected and tested and is warranted f or one year f or par ts and labor . If questions ar ise while installing or using this product, contact T echnical Support at +1 (301) 975-1007 . 2.1 FEATURES • Easy-to-install T1/E1 Extenders? ...
-
Patton electronic 2115 - page 9
9 3.0 INSTALLATION Because the CopperLink-T T1/E1 Extenders require no configuration, they can be installed quickly . Installation consists of the follo wing: • Connect the power plug (ref er to section 3.1, “Connecting P ower” on page 10). • Connect the line por t (refer to section 3.3, “Connecting the Line P or t” on page 11) Note Se ...
-
Patton electronic 2115 - page 10
10 3.1 CONNECTING POWER Y our CopperLink-T T1/E1 Extender comes with an e xter nal A C adaptor with a detachable po wer cord. T o connect power to the CopperLink-T : 1. Connect the f emale plug of the AC po wer cord to the AC adaptor provided. 2. Connect the barrel-type connector of the A C adaptor to the P ower connector on the CopperLink-T . 3. I ...
-
Patton electronic 2115 - page 11
11 3.3 CONNECTING THE LINE PORT F ollow the steps below to connect the CopperLink-T line port: 1. Obtain a single-twisted pair cable with an RJ-45 plug connector at each end. 2. Plug one end of the cable into the RJ-45 sock et (labeled Line) on the CopperLink-T . 3. When the remote and local e xtender units synchronize, the front- panel Link LED wi ...
-
Patton electronic 2115 - page 12
12 Note The unit marked as 2113/L or 2115/L is configured by def ault to accept timing from the T1/E1 circuit. The 2113/ R or 2115/R unit then recov ers this timing from the line in order to ensure synchronization of the T1/E1 circuit over the e xtenders. Figure 4. The label showing the specific model number on the bottom of the unit Gaithersburg ...
-
Patton electronic 2115 - page 13
13 4.0 OPERATION Once the CopperLink-T T1/E1 Extenders are proper ly installed, they should operate transparently . No user settings required. This section describes reading the LED status monitors. 4.1 FRONT PANEL LED STATUS MONITORS Models 2113 and 2115 f eature three front-panel LEDs that monitor po wer , Ethernet signals, and the CopperLink con ...
-
Patton electronic 2115 - page 14
14 4.2 CONFIGURATION AND DIP SWITCHES The CopperLink-T™ T1/E1 Extenders are Plug ‘n’ Play enab led and do not require any configuration b y the user . Note The user should NO T change any of the dip switches except for S1-7 (if necessary). If the user changes the position of any of the dip switches (except for S1-7), it will affect the opera ...
-
Patton electronic 2115 - page 15
15 APPENDIX A SPECIFICATIONS A.1 CIRCUIT RATES • Model 2113 - 2.048 Mbps • Model 2115 - 1.544 Mbps A.2 CIRCUIT INTERFACE • E1 (Model 2113) presents G.703/G.704 interf ace. Either 75 Ohms (unbal- anced) or 120 Ohms (balanced). Pins 1 & 2 are Receive . Pins 4 & 5 are transmit. • T1 (Model 2115) present T1 interf ace. Pins 1 & 2 ar ...
-
Patton electronic 2115 - page 16
16 A.7 ENVIRONMENTAL • T emperature: 32–122°F (0–50°C) • Relative Humidity: 5–95%, non-condensing • Altitude: 0–15,000 ft (0–4,572 m) A.8 T RANSMISSION LINE • Single T wisted Pair A.9 LINE CODING • TC-P AM (T rellis Coded Pulse Amplitude Modulation) A.10 LINE INTERFACE • T ransf ormer coupled, 2500 VRMS isolation A.11 LINE P ...
-
Patton electronic 2115 - page 17
17 APPENDIX B F ACTOR Y DEFAULT DIP SWITCH CONFIGUR ATION Note This information is provided f or informational pur poses only . These settings should not be changed other than by instructions from P atton Suppor t, lest the unit be rendered inoperab le. B.1 SWITCH S1 - FACTORY DEFAULT CONFIGURATION B.2 SWITCH S2 - FACTORY DEFAULT CONFIGURATION T ab ...
-
Patton electronic 2115 - page 18
18 NO TES _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ __________________________________________________ ...
-
Patton electronic 2115 - page 19
19 NO TES _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ __________________________________________________ ...
-
Patton electronic 2115 - page 20
20 NO TES _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ __________________________________________________ ...
Haben Sie eine Frage bezüglich Patton electronic 2115?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Patton electronic 2115 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Patton electronic 2115 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.