Bedienungsanleitung Icom DS-100

36 Seiten 0.26 mb
Download

Zur Seite of 36

Summary
  • Icom DS-100 - page 1

    INSTRUCTION MANUAL DS-100 DSC CONTROLLER ...

  • Icom DS-100 - page 2

    i FOREWORD Thank you for purchasing this Icom product. The DS-100 DSC CONTROLLER is designed and built with Icom’s superior tech- nology and craftsmanship. With proper care this product should provide you with years of trouble-free operation. IMPOR T ANT READ ALL INSTRUCTIONS carefully and com- pletely before using the controller . SA VE THIS INS ...

  • Icom DS-100 - page 3

    ii CAUTIONS R W ARNING! NEVER connect the controller to an AC outlet. This may pose a fire hazard or result in an electric shock. R W ARNING NEVER transmit a distress call when your vessel does not need immediate help. Distress calls can be used only in times of emergency . NEVER connect the controller to a power source of more than 16 V DC. Such a ...

  • Icom DS-100 - page 4

    iii FOREWORD ........................................................................ i IMPORT ANT ........................................................................ i EXPLICIT DEFINITIONS ...................................................... i FEA TURES .......................................................................... i W ARNING .. ...

  • Icom DS-100 - page 5

    1 1 P ANEL DESCRIPTION ■ Front panel q DISTRESS BUTTON Push and hold for 5 sec. to make a distress call. w CLEAR SWITCH [CLR] ➥ Push this key to cancel Call repeat. ➥ Push this key to cancel the menu. e CALL SWITCH [CALL] ➥ Push this key to call subject menu screen. ➥ Push the key to return the start screen. r ENTER [ENT] ➥ Enters the s ...

  • Icom DS-100 - page 6

    2 1 P ANEL DESCRIPTION must be set in advance. NOTE: If GPS data is interrupted for 30 sec. the “GPS” indi- cation disappears. The terminal unit retains the most recent data in such cases. ■ Function display q GPS INDICA TOR ➥ “GPS” appears while GPS receiver is connected. ➥ “GPS’ disappears when no GPS receiver is connected. ➥ ...

  • Icom DS-100 - page 7

    2 CALL PROCEDURE 3 ■ Distress call/ Simple operation A distress call should be transmitted if, in the opnion of the Master , the ship or a person is in distress and requires imme- diate assistance. A distress call should include the ship’ s position and time. They are included automatically when a GPS receiver is con- nected. If no GPS is conne ...

  • Icom DS-100 - page 8

    CALL PROCEDURE 2 4 ■ Distress call/ Regular operation T ransmit a distress call after selecting the ‘Distress setting’. NEVER: USE THE DISTRESS CALL WHEN YOUR SHIP IS NOT IN AN EMERGENCY . DIS- TRESS CALL CAN BE USED ONL Y WHEN IM- MEDIA TE HELP IS NEEDED. q Push [CALL], then push [ √ ] several times to select ‘Dis- tress setting’. w Pu ...

  • Icom DS-100 - page 9

    2 CALL PROCEDURE 5 NOTE: • ‘nature of distress’ will be recorded for 10 min. until a distress call transmits. • Distress call repeats every 3.5–4.5 min., until receiving an ‘ac- knowledgement’ • Beep (Pi,Pi) sounds with the max. volume every 1 sec. • Push [DISTRESS] button to transmit a renewed distress call. • Push [CLR] to can ...

  • Icom DS-100 - page 10

    CALL PROCEDURE 2 6 y Push UTC time with keypad. • Push [ Ω ]/[ ≈ ] to move the cursor then push [ Y ]/[ Z ] to correct the data • Push [CLR] to Exit the menu. • Push [A/a], then push [ENT] to enter ‘Null data’. ■ Distress call to ships General DSC call with the ‘distress’ category may be used for communications after the Distres ...

  • Icom DS-100 - page 11

    7 2 CALL PROCEDURE ■ Group call q Push [CALL], then push [ √ ] one or more times to select ‘Group call’, then push [ENT]. w Select the desired address, then push [ENT]. • Enter the 8 digit address when ‘Manual entry’ is selected. e Push [CALL] and [ENT] si- multaneously to transmit a ‘Group call’. r Push [CLR] to stop the call. ? ...

  • Icom DS-100 - page 12

    CALL PROCEDURE 2 8 D When no acknowledgement is received If no acknowledgement is received, the emergency alarm will sound continuously . In this case, the controller automatically tramsmits the distress call again every 3.5 to 4.5 minutes. • Push [CLR] if you want to stop the alarm. • A distress relay call may be received after several min- ut ...

  • Icom DS-100 - page 13

    9 3 WHEN RECEIVING A CALL ■ T o receive a DSC call D When receiving a DSC call Y ou should act in one of the following ways depending on the received DSC format (or category): • W ait for a voice transmission on the traffic frequency . • T ransmit an acknowledgement with DSC or voice. • T ransmit a distress relay call (only when the ship i ...

  • Icom DS-100 - page 14

    ■ When receive a Distress call D When receiving a Distress call When receiving a distress call, an alarm (Pi-po) sounds with max. AF level continuously . And at the same time, the trans- ceiver ’ s (IC-M501EURO) oper- ating channel changes to CH 16 automatically . • Push [CLR] to cancel the alarm. D When receiving an individual call When rece ...

  • Icom DS-100 - page 15

    WHEN RECEIVE A CALL 11 3 D When receiving an All ships call When receiving a Routine or Safety all ships call, an alarm (Pi-pi) sounds. When you receive a distress or Urgency all ships call, an alarm (Pi-po) sounds with max. AF level continuously . • Push [CLR] to cancel the alarm. • Push [ENT], then the oper- ating channel changes to received ...

  • Icom DS-100 - page 16

    WHEN RECEIVING A CALL 3 12 D When receiving a Distress ACK When receiving a distress ac- knowledgement, an alarm (Pi- po) sounds with max. AF level continuously . And at the same time, the transceiver’s (IC- M501EURO) operating channel changes to CH 16 automati- cally . • Push [CLR] to cancel the alarm. D When receiving a Distress Relay ACK Whe ...

  • Icom DS-100 - page 17

    13 3 WHEN RECEIVING A CALL ■ Received message (RCV MSG) When receiving a DSC call, the received format specifier and its contents are memorized into the received message (RCV MSG) memory . Distress calls (including other calls with dis- tress category) are stored separately from other calls. Up to 20 distress calls can be memorized and up 20 oth ...

  • Icom DS-100 - page 18

    3 14 WHEN RECEIVING A CALL D Other messages • Individual call q Push [CALL], then push [ √ ] several times to select ‘Re- ceived calls’, then push [ENT]. w Select ‘Other message’, then push [ENT]. e Select ‘Individual call’, then push [ENT]. • Push [ Y ] or [ Z ] to scroll the message. • Push [A/a] to clear the mes - sage. • G ...

  • Icom DS-100 - page 19

    3 15 WHEN RECEIVING A CALL • All ships q Push [CALL], then push [ √ ] several times to select ‘Re- ceived calls’, then push [ENT]. w Select ‘Other message’, then push [ENT]. e Select ‘All ships call’, then push [ENT]. • Push [ Y ] or [ Z ] to scroll the message. • Push [A/a] to clear the message. • Distress q Push [CALL], then ...

  • Icom DS-100 - page 20

    16 3 WHEN RECEIVING A CALL • Distress relay acknowledgement q Push [CALL], then push [ √ ] several times to select ‘Re- ceived calls’, then push [ENT]. w Select ‘Other message’, then push [ENT]. e Select ‘Distress RL Y ACK’, then push [ENT]. • Push [ Y ] or [ Z ] to scroll the message. • Push [A/a] to clear the mes - sage. . • ...

  • Icom DS-100 - page 21

    17 4 SET -UP ■ Select ‘Set-up’ The following setting/operations available in ‘Set-up’ menu. • Address ID • Of fset time • Brightness • Contrast • MMSI check q Push [CALL], then push [ √ ] several times to select ‘Set- up’, then push [ENT]. w Select ‘Set-up’, then push [ENT]. • ‘Set-up’ menu appears on the screen. ...

  • Icom DS-100 - page 22

    4 SET -UP 18 • Delete address ID q Push [ √ ] to select ‘Delete address ID’, then push [ENT]. w Push [ ∫ ]/[ √ ] several times to select a desired address ID that you want to delete, then push [ENT]. • Address ID and name is dis- played on the screen. e Push [ENT] to delete the ad- dress ID. • Push [CLR] to exit the screen. r Push [ ...

  • Icom DS-100 - page 23

    4 SET -UP 19 ■ Offset time Local time can be used when the GPS position data is valid and off set time is input. q Push [CALL], then push [ √ ] one or more times to select ‘Set-up’, then push [ENT]. w Select ‘Offset time’, then push [ENT]. e Push “0; –” or “1; space”, then input the time differences. r Push [ENT] to determine ...

  • Icom DS-100 - page 24

    CONNECTION AND INST ALLA TIONS 5 20 t y q r e w IC-M501EURO DS-100 13.8V DC GND u ■ Connection diagram NOTE: Binding the GPS cable, GPS connector and clone receptacle with the water resistant tape, increases the water-proo fi ng of the controller . ...

  • Icom DS-100 - page 25

    5 21 CONNECTION AND INST ALLA TIONS ■ Rear panel description q CONNECTION CABLE Connets to the IC-M501EURO rear DSC controller recep- tacle. w RECEIVE ANTENNA CONNECTOR Connects a marine VHF receiving antenna with a PL-259 plug for emergency frequency signal receiving. • Receiving frequency : 156.525 MHz • Keep the emergency frequency signal ...

  • Icom DS-100 - page 26

    5 22 CONNECTION AND INST ALLA TIONS ■ Mounting The universal mounting bracket supplied with your controller allows dashboard or overhead mounting. Please read the fol- lowing instructions carefully . • Mount the controller securely with bolts and nuts or it may come loose as a result of wave shocks or vibration. • Mount the controller so that ...

  • Icom DS-100 - page 27

    6 VHF MARINE CHANNEL LIST 23 Frequency (MHz) CH Frequency (MHz) CH T ransmit Receive T ransmit Receive 156.550 156.550 156.050 160.650 156.600 156.600 156.650 156.650 156.700 156.700 156.100 160.700 156.750 156.750 156.800 156.800 156.850 156.850 156.150 160.750 156.900 161.500 156.950 161.550 157.000 161.600 156.200 160.800 11 12 13 14 15 16 156.2 ...

  • Icom DS-100 - page 28

    24 7 SPECIFICA TIONS AND OPTIONS ■ Options MB-75 FLUSH MOUNTER For mounting the DS-100 to a panel. Available in black or white. CS-DS100 CLONING SOFTW ARE OPC-478 CLONING CABLE Allows quick and simple setting of vessel name, call sign, ID, etc. from a PC. ■ Speci fi cations General • Operating frequency : 156.525 MHz • Mode : 16K0G2B • O ...

  • Icom DS-100 - page 29

    25 8 DIMENSIONS (Unit: mm) 165.0 84.4 110.0 31.4 53.0 25.0 145.0 ...

  • Icom DS-100 - page 30

    9 MB-75 (OPTION) 26 ■ MB-75 FLUSH MOUNT KIT The MB-75 is used to mount the DS-100 DSC CON- TROLLER fl ush to a fl at surface such as an instrument panel. • Supplied accessories Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 sets • Instructions q Using the template (p. 29), carefully cut a hole into the in- strum ...

  • Icom DS-100 - page 31

    9 MB-75 27 e Using the 2 supplied bolts (M5 x 8 mm), attach the clamps on either side of the DS-100 as shown below . • Make sure that the clamps align parallel to the DS-100 ’ s body . r T ighten the end bolts on the clamps (rotate clockwise) so that the clamps press firmly against the inside of the in- strument control panel. t T ighten the lo ...

  • Icom DS-100 - page 32

    ...

  • Icom DS-100 - page 33

    TEMPLA TE 164 (6 15 / 32 ) 149 (5 7 / 8 ) 16 ( 5 / 8 ) 92 (3 5 / 8 ) 4 – R11( 7 / 16 ) Unit: mm (inch) Cut here ...

  • Icom DS-100 - page 34

    ...

  • Icom DS-100 - page 35

    DECLARATION OF CONFORMITY We Icom Inc. Japan 6-9-16, Kamihigashi, Hirano-ku Osaka 547-0002, Japan Kind of equipment: DSC CONTROLLER This compliances is based on conformity with the following harmonised standards, specifications or documents: i) EN 301 025-2 V0.1.2 (2000-02) ii) EN 60945 1997 iii) prETS 300 698 December 1996 iv) v) Type-designation: ...

  • Icom DS-100 - page 36

    Count on us! 6-9-16 Kamihigashi, Hirano-ku, Osaka 547-0002 Japan A-5654H-1EU- q Printed in Japan © 2000 Icom Inc. ‘  GER ‘  AUT ‘  GBR ‘  IRL ‘  FRA ‘  NED ‘  BEL ‘  LUX ‘  ESP ‘  POR ‘  ITA ‘  GRE ‘  SWE ‘  DEN ‘  FIN < Intended Country of Use > ...

Produzent Icom Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts Icom DS-100 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Icom
- Bedienungsanleitungen DS-100
- Produktkarten Icom
- Informationsbroschüren
- oder Energieetiketten Icom DS-100
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Icom DS-100.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Icom DS-100, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Icom DS-100. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Icom DS-100 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Icom DS-100, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Icom DS-100 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Icom DS-100 verständlich ist.

Eine gänzliche Bedienungsanleitung von Icom sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Icom DS-100 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Icom DS-100 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Icom DS-100, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Icom DS-100 - die uns die ersten Schritte während der Nutzung von Icom DS-100 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Icom DS-100 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Icom DS-100 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Icom DS-100?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Icom DS-100 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Icom DS-100 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen