Bedienungsanleitung Lopi 1750

36 Seiten 1.57 mb
Download

Zur Seite of 36

Summary
  • Lopi 1750 - page 1

    1 7 5 0 W o o d S t o v e Owner's Manual • Freestanding Stove • Mobile-Home Approved • Alcove Approved • Hearth-Stove Approved Save these instructions for future reference S A FE TY N OTIC E: If thi s appl i anc e i s not properly i ns tal l ed, a house fi re may re sult. For your safety, follow the install ation dire cti ons. C ontac ...

  • Lopi 1750 - page 2

    2 Introduction © Travis Industrie s 100-0117 9 4060 926 Introduction We welcome you as a new owner of a 1750 wood-burning stove. In purchasing a 1750 you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The 1750 is one of the finest appliances the ...

  • Lopi 1750 - page 3

    Table of Contents 3 © Travis Industrie s 100-011 79 4060 926 General Information Introduction & Important Information ...................... 2 Safety Precautions ............................................ 4 Features & Specifications .................................... 6 Stove Installation Planning the Installation ...................... ...

  • Lopi 1750 - page 4

    4 Safety Precautions © Travis Industries 100-01179 4060926 The viewing door must be closed and latched during operation. Never block free airflow through the air vents on this appliance. Gas Gasoline or other flammable liquids must never be used to start the fire or "Freshen Up" the fire. Do not store or use gasoline or other flammable l ...

  • Lopi 1750 - page 5

    Safety Precautions 5 © Travis Industries 100-01179 4060926 Mobile Home When installed in a mobile home, this appliance must be bolted to the floor, have outside air, and not be installed in the bedroom (Per H.U.D. requirements). Check with local building officials. Do not place clothing or other flammable items on or near this appliance. Never try ...

  • Lopi 1750 - page 6

    6 Features & Specifications © Travis Industries 100-01179 4060926 Installation Options • Freestanding • Freestanding in an Alcove • Freestanding in a Mobile Home • Freestanding Hearth Stove Features • EPA Phase II Approved • 2.2 Cubic Foot Firebox Volume • Single Operating Control • Accepts Logs Up to 18” Long • Steel Plate ...

  • Lopi 1750 - page 7

    Stove Installation (for qualified installers only) 7 © Travis Industries 100-01179 4060926 SAFETY NOTICE: P lease r ead t h is en tir e m an ua l b efo r e yo u in st all an d use yo u r new r oo m heat er . F ailu r e to fo llo w in st r u ct io n s m ay r esu lt in p r o p er ty d am ag e, b o dily injur y, or even deat h. C ontac t loc a l bui ...

  • Lopi 1750 - page 8

    8 Stove Installation (for qualified installers only) © Travis Industries 100-01179 4060926 Floor Protection Requirements • Stove must be placed on the Travis Industries legs or Pedestal. • Floor protection must extend 6" to the sides and rear of the stove and 16" to the front of the stove (36" wide by 45-1/2" deep - see Fig ...

  • Lopi 1750 - page 9

    Stove Installation (for qualified installers only) 9 © Travis Industries 100-01179 4060926 Top View - Straight Installation Measure rear and side clearances from the nearest edge of the stove top. Floor Protection 24” 23-1/2” 16” Min. Measure front clearances from the face of the stove (unibody). 6” Min. 6” Min. Clearance A NOTE: vent di ...

  • Lopi 1750 - page 10

    10 Stove Installation (for qualified installers only) © Travis Industries 100-01179 4060926 Chimney Connector Requirements • Chimney connector is required from the flue collar of the stove to the factory-built chimney (see Figure 5 ) or masonry chimney (see Figures 13, 14, and 15). • The chimney connector must be 6” diameter and a minimum 24 ...

  • Lopi 1750 - page 11

    Stove Installation (for qualified installers only) 11 © Travis Industries 100-01179 4060926 Chimney Requirements • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. • UL 103 HT Chimney must be used from the first ceiling or floor penetration to the chimney cap. • Use 6" diameter type UL 103 HT chimney from one manufa ...

  • Lopi 1750 - page 12

    12 Stove Installation (for qualified installers only) © Travis Industries 100-01179 4060926 Chimney Termination Requirements • Must have an approved cap (to prevent water from entering) • Must not be located where it will become plugged by snow or other material • Must terminate at least 3' above the roof and at least 2' above any ...

  • Lopi 1750 - page 13

    Stove Installation (for qualified installers only) 13 © Travis Industries 100-01179 4060926 Alcove Installation Requirements Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the special installation requirements listed below must b ...

  • Lopi 1750 - page 14

    14 Stove Installation (for qualified installers only) © Travis Industries 100-01179 4060926 Mobile Home Requirements • Outside air must be installed - see "Outside Air Requirements" on page 12 • Chimney connector and chimney must be one of the following types: AMERI-TEC model DCC with model HS chimney DURAVENT model DVL with DURATEC ...

  • Lopi 1750 - page 15

    Stove Installation (for qualified installers only) 15 © Travis Industries 100-01179 4060926 Standard Ceiling with a Factory Built Chimney Chimney Cap (See the section "Chimney Termination Requirements" for more details) Chimney Sections Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions - usually 2") Chi ...

  • Lopi 1750 - page 16

    16 Stove Installation (for qualified installers only) © Travis Industries 100-01179 4060926 Exterior Factory Built Chimney NOTE: Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures. An insulated chase will reduce these accumulations (the proper clearances to the chimney must be maintained). C h ...

  • Lopi 1750 - page 17

    Stove Installation (for qualified installers only) 17 © Travis Industries 100-01179 4060926 Hearth Stove Direct Connection NOTE: Direct connections require installation of an airtight, non-combustible block-off plate or damper adapter. Block-off plate or damper adapter Remove damper or wire it open Airtight Insulated Clean-Out Stainless steel chim ...

  • Lopi 1750 - page 18

    18 Operating Your Appliance © Travis Industries 100-01179 4060926 Safety Notice If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read and follow all of the warn ...

  • Lopi 1750 - page 19

    Operating Your Appliance 19 © Travis Industries 100-01179 4060926 Opening the Door The door becomes hot during use. Use a glove to open the door if the handle is hot. Avalon Spokane Door Rotate the door handle. Swing the door open. Lopi Republic Door Swing the door open. Rotate the door handle. ...

  • Lopi 1750 - page 20

    20 Operating Your Appliance © Travis Industries 100-01179 4060926 Starting a Fire Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee", some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire starting. • Make sure the air contr ...

  • Lopi 1750 - page 21

    Operating Your Appliance 21 © Travis Industries 100-01179 4060926 Adjusting the Burn Rate Use the air control slider to control the burn rate of the stove. See the illustration below for details. Low Burn (air control closed) High Burn (air control open) Use the air control to change the burn rate. Approximate Air Control Settings Overnight Burn F ...

  • Lopi 1750 - page 22

    22 Operating Your Appliance © Travis Industries 100-01179 4060926 Optional Blower Operation The blower is available to assist the convection chamber in distributing heat to your home. The directions below detail the options you have with the blower and the best method for operation. OFF Turn the dial all the way counter- clockwise until it clicks ...

  • Lopi 1750 - page 23

    Operating Your Appliance 23 © Travis Industries 100-01179 4060926 Hints for Burning • Get the appliance hot before adjusting to low burn • Use smaller pieces of wood during start-up and high burns to increase temperature • Use larger pieces of wood for overnight or sustained burns • Stack the wood tightly together to establish a longer bur ...

  • Lopi 1750 - page 24

    24 Operating Your Appliance © Travis Industries 100-01179 4060926 Troubleshooting Problem Possible Cause Smoke Enters Room During Start-Up • Open the air control (pg. 21). • Cold Air Blockage - burn a piece of newspaper to establish a draft. • If the flame is not getting enough air, a small crack in the door is all that is needed. Kindling D ...

  • Lopi 1750 - page 25

    Maintaining Your Appliance 25 © Travis Industries 100-01179 4060926 Failure to properly maintain and inspect your appliance may reduce the performance and life of the appliance, void your warranty, and create a fire hazard. Daily Maintenance (while stove is in use) Remove Ash (if necessary) • Ash removal is not required once it builds up. 1/2&qu ...

  • Lopi 1750 - page 26

    26 Maintaining Your Appliance © Travis Industries 100-01179 4060926 Monthly Maintenance (while appliance is in use) Make sure the appliance has fully cooled prior to conducting service. Door and Glass Inspection The door must form an air-tight seal to the firebox for the stove to work correctly. Inspect the door gasket to make sure it forms an air ...

  • Lopi 1750 - page 27

    Maintaining Your Appliance 27 © Travis Industries 100-01179 4060926 Yearly Maintenance Make sure the appliance has fully cooled prior to conducting service. Touch Up Paint Included with the owner's pack of this appliance is a can of Stove-Brite® paint. To touch up nicks or dulled paint, apply the paint while the appliance is cool. Sand ruste ...

  • Lopi 1750 - page 28

    28 Maintaining Your Appliance © Travis Industries 100-01179 4060926 Door Parts Avalon Spokane Door 1 2 7 3 4 5 6 8 14 13 Lopi Republic Door 1 3 12 11 10 9 8 4 5 14 13 ID # Description Qty Part # ID # Description Qty Part # 1 Glass Gasket 1 250-00173 2 Avalon Glass 1 250-00177 3 Glass Clip w Gasket– 3 Hole 2/1 250-00174 4 Door Gasket 1 250-00170 ...

  • Lopi 1750 - page 29

    Maintaining Your Appliance 29 © Travis Industries 100-01179 4060926 Firebox Parts 1 3 4 2 13 12 6 5 8 11 11 11 11 11 11 14 11 11 11 11 11 ID # Description Qty Part # ID # Description Qty Part # 1 Air Tubes & Sleeve 1 98900233 2 Air Tube Roll Pins 6 98900357 3 Air Tube Retainer Sleeve 3 98900356 4 Baffle Support, Front 1 99900251 5 Baffle Suppo ...

  • Lopi 1750 - page 30

    30 Maintaining Your Appliance © Travis Industries 100-01179 4060926 Air Tube Removal & Replacement All three air tubes are identical. a b Remove the left pin on the air tube collar Air Tube Collar Air Tube Slide the air tube to the left, swing it down and remove from the firebox. Roll Pin Baffle Removal & Replacement 1 Push the front fireb ...

  • Lopi 1750 - page 31

    Limited 5 Year Warranty 31 © Travis Industries 100-01179 4060926 To register your TRAVIS INDUSTRIES, INC. 5 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this appliance ...

  • Lopi 1750 - page 32

    32 Limited 5 Year Warranty © Travis Industries 100-01179 4060926 CONDITIONS & EXCLUSIONS 1. This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with the instructions in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the pr ...

  • Lopi 1750 - page 33

    Optional Equipment 33 © Travis Industries 100-01179 4060926 Listing Label The listing label (safety label) is attached to the back of the stove. A copy is shown below. ...

  • Lopi 1750 - page 34

    34 Optional Equipment © Travis Industries 100-01179 4060926 Stove Leg Installation Part Numbers: Brass # 99200500, Cast Black # 99200800, Sculptured Steel # 99200105 • Raise the stove 8" (use lumber). Attach each leg following the instructions below. Attach each leg to the stove by inserting a bolt and washer through the hole or slot in the ...

  • Lopi 1750 - page 35

    Optional Equipment 35 © Travis Industries 100-01179 4060926 Rear Blower Installation (Part # 99000138) The rear blower improves heat transfer by pushing heated air through the convection channel. Operating instructions are described in the section "Blower Operation". Twist the wires together on the snap disk assembly. Wedge the snap disk ...

  • Lopi 1750 - page 36

    36 Index © Travis Industries 100-01179 4060926 Air Control (Adjusting the Burn Rate) . . . . . . . . . . . . . . . . . . . . . . . 21 Alcove Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 A s h R e m o v a l ...................................................... 2 1 A s h R e m o v a l ........................ ...

Produzent Lopi Kategorie Stove

Dokumente, die wir vom Produzenten des Geräts Lopi 1750 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lopi
- Bedienungsanleitungen 1750
- Produktkarten Lopi
- Informationsbroschüren
- oder Energieetiketten Lopi 1750
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lopi 1750.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lopi 1750, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lopi 1750. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lopi 1750 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lopi 1750, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lopi 1750 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lopi 1750 verständlich ist.

Eine gänzliche Bedienungsanleitung von Lopi sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lopi 1750 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lopi 1750 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lopi 1750, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lopi 1750 - die uns die ersten Schritte während der Nutzung von Lopi 1750 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lopi 1750 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lopi 1750 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lopi 1750?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lopi 1750 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lopi 1750 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.