Bedienungsanleitung National Instruments Toolkit

35 Seiten 0.47 mb
Download

Zur Seite of 35

Summary
  • National Instruments Toolkit - page 1

    USER GUIDE NI Spectral Measurements T oolkit This document explains how to use th e NI Spectral Meas urements Toolkit (SMT) in LabVIEW and LabWindows ™ /CVI ™ for freq uency-domain measurements. Contents Conventions .............. .............. .............. .............. .............. .............. ........ 2 Using the Spectral Measuremen ...

  • National Instruments Toolkit - page 2

    NI Spectral Measurements T oolkit User Guide 2 ni.com Averaged Cross Spectrum ................. .............. .............. ................. .. 28 Averaged Frequency Response ............... .............. ................. ..........29 Spectral Domain Measurements ..................... .............. ................. ..........29 Unit Conversi ...

  • National Instruments Toolkit - page 3

    © National Instruments Corporation 3 NI Spectral Measurements T oolkit User Guide Using the Spectral Measurements T oolkit The Spectral Measurements Tool kit contains LabVIEW VIs and LabWindows/CVI functions that perform the fo llowing operations: • Zoom frequency analysis—Zoom fast Fourier transform (FFT) functions and VIs allow you to zoom i ...

  • National Instruments Toolkit - page 4

    NI Spectral Measurements T oolkit User Guide 4 ni.com Integrating the Spectral Measurements T oolkit You can use the Spectral Meas urem ents Toolkit for the fo llowing applications: • Frequenc y-domain measurements such as: – Adjacent channel po wer ratio (A CPR) – Channel spectrum – Power -in-band measurements – A v e rage and peak power ...

  • National Instruments Toolkit - page 5

    © National Instruments Corporation 5 NI Spectral Measurements T oolkit User Guide SMT Programming Flow Diagram Programming flow diag rams are flowch arts that depict the most effective order for programming Spectral Meas urem ents Toolkit VIs. Use the programming flow diagram in the SMT Programming Flow VI as a visual guide for the order in which ...

  • National Instruments Toolkit - page 6

    NI Spectral Measurements T oolkit User Guide 6 ni.com 2. Enter the output power spectrum into an SMT measurem ent VI and/or use the SMT Spectrum Unit Con version VI as follo ws: a. Enter the output power spectrum into an SMT measurem ent VI: the SMT Po wer in Band, the SMT Adjacent Channel Power , or the SMT Occupied Bandwidth VI . These V Is accep ...

  • National Instruments Toolkit - page 7

    © National Instruments Corporation 7 NI Spectral Measurements T oolkit User Guide For an a veraged power spectrum w ith zoom, use the SMT Zoom Po wer Spectrum VI. For an a veraged FFT spectrum, which has a complex output for magnitude and phase calcu lations, use the SMT Zoom FFT VI first a n d then the SMT A veraged FFT Spectrum VI. If you have t ...

  • National Instruments Toolkit - page 8

    NI Spectral Measurements T oolkit User Guide 8 ni.com The averaging parameters cluster specifies the following settings: • A v eraging type, such as vector av eraging, RMS averaging, or peak hold • W eigh ting type, such as linear or exponential • A v e raging size The linear w eighting mode parameter specifies a type of linear weighting. The ...

  • National Instruments Toolkit - page 9

    © National Instruments Corporation 9 NI Spectral Measurements T oolkit User Guide The channel specification parameter specifies the center frequency , bandwidth , and spaci ng for the A CP measurement. The bandwidth parameter specifies the width of each c hannel. The spacing parameter specifies the separation between the center frequencies of each ...

  • National Instruments Toolkit - page 10

    NI Spectral Measurements T oolkit User Guide 10 ni.com Cross Power Spectrum Measurement The Cross Power Spectrum Measur ement example is located at samples smtsimulatedsmtcrspwrsmtcrspwr.pr j . This example demonstrates ho w to co nfigure the zoom FFT , then calculates the av eraged power spectrum of a st imulus and response signal from a de vi ...

  • National Instruments Toolkit - page 11

    © National Instruments Corporation 11 NI Sp ectral Measurements T oolkit User Guide Figure 2. Zoom FF T T echnique FFT algorithms usually pe rform baseband analysis by displaying the spectrum from zero to the Nyquist frequency . Ho wever , a standard FFT might not be effecti ve if you need to obtain a higher frequency resolution ov er a li mited p ...

  • National Instruments Toolkit - page 12

    NI Spectral Measurements T oolkit User Guide 12 ni.com Continuous Zoom FF T Continuous zoom FFT is a technique for quickly analyzing data as it arrives. A decimation process reduces th e sample rate in real time. After the process acquires all the data and d ecimates it in time T , a relatively small FFT remains. The term continuous refers to begin ...

  • National Instruments Toolkit - page 13

    © National Instruments Corporation 13 NI Sp ectral Measurements T oolkit User Guide The continuous zoom FFT technique is sometimes called the real-time zoom FFT because it continuously performs the frequency shifting, decimation, and filtering processes on the arriving data. The FFT operation itself cannot proceed until you acquire all the da ta. ...

  • National Instruments Toolkit - page 14

    NI Spectral Measurements T oolkit User Guide 14 ni.com Block Zoom FF T Use a block zoom FFT in situations when you cannot access data until the data acquisition is complete. The bl ock zoom FFT is a nondest ructiv e zoom FFT because it stores data before proce ssing, so the data is av ailable in its original form if you need it for oth er operation ...

  • National Instruments Toolkit - page 15

    © National Instruments Corporation 15 NI Sp ectral Measurements T oolkit User Guide The block zoom FFT is a general-purpose technique that works best as a post-processing method. The block zoom FFT also is useful for real-time applications where the data rate is too high for a continuous zoom FFT to sustain in real time. T o process the en tire da ...

  • National Instruments Toolkit - page 16

    NI Spectral Measurements T oolkit User Guide 16 ni.com Figure 5. Sp ectrogram Process Example The SMT Config Zoom STFT VI specif ies the spectrogram in terms of its center frequency , frequency span, and time span. The frequency span controls the FFT zoom. If the center fr equency is 10 MHz and the span is 2 MHz, the SMT Config Zoom STFT VI calc ul ...

  • National Instruments Toolkit - page 17

    © National Instruments Corporation 17 NI Sp ectral Measurements T oolkit User Guide ef fectiv e band specification. If you lea ve the default adv anced parameters, the configuration VI calculates the co rrect parameters for a spectrogram with ev enly distributed time and frequency resolution on a square display area. If the display area is not s q ...

  • National Instruments Toolkit - page 18

    NI Spectral Measurements T oolkit User Guide 18 ni.com Configuring Zoom FF T VIs When using Spectral Measurements To olk it VIs, you must enter several values to completely specify a z oom FFT. The Spectral Measurements Toolkit provides two config uration VIs that select values for each setting and that require you to en ter a minimal num ber of va ...

  • National Instruments Toolkit - page 19

    © National Instruments Corporation 19 NI Sp ectral Measurements T oolkit User Guide The left side of Figure 7 sho ws exam ples of the four combinations of center frequency and span that you can encounter in the case of a real input signal. The right side of Figure 7 shows the actual coerced v alues of center frequency and span that the VI sets in ...

  • National Instruments Toolkit - page 20

    NI Spectral Measurements T oolkit User Guide 20 ni.com that is outside the ef fect iv e band, the span changes to the default v alue, which is the center of the ef fectiv e ba nd. Figure 7c demonstrates that if you request a span that i s wider than the effecti ve band, the span decreases until it falls entirely within the effecti ve band without m ...

  • National Instruments Toolkit - page 21

    © National Instruments Corporation 21 NI Sp ectral Measurements T oolkit User Guide Figure 8 shows the shape of the equiv ale nt filter corr esponding to a 7-T erm Blackman-Harris window . The cursors ar e placed at the 3 dB points of the filter response, and the resolution ba ndw idth is the distance between the cursors. spectral lines controls h ...

  • National Instruments Toolkit - page 22

    NI Spectral Measurements T oolkit User Guide 22 ni.com The acquisition size comes from the following basic relationshi p: df = f s / N = 1/ T where N is equal acquisition size and RBW is the frequency resolution df multiplied by the w indow spectral leakage correction factor of 3 dB bandwidth. If the spectral lines value requires a lar ger acquisit ...

  • National Instruments Toolkit - page 23

    © National Instruments Corporation 23 NI Sp ectral Measurements T oolkit User Guide Figure 9 shows the spectrum of a mu ltiton e signal calculated using two RBW values. The multitone si gnal cons ists of two tones, at frequenci es 1.0 MHz and 1 .1 MHz, separated by 100 kHz. T able 1 shows the trade-of fs of using two dif ferent RBWs. Note An RBW o ...

  • National Instruments Toolkit - page 24

    NI Spectral Measurements T oolkit User Guide 24 ni.com Spectral Domain A veraging Averaging is an important part of spectrum-domain measurements because of the effects of noise on a s igna l and its spectr um. The Spectral Measurements Toolkit includes av eraging VIs that average several records of data to reduce the noise eff ects. You can use the ...

  • National Instruments Toolkit - page 25

    © National Instruments Corporation 25 NI Sp ectral Measurements T oolkit User Guide The av eraging VIs require that you enter an FFT spectrum as a complex array . Y ou can perform spectrum unit con version before or after a veraging. A veraging Conventions For Spectral Measurements Toolkit VIs, averaging refers to the average of several different ...

  • National Instruments Toolkit - page 26

    NI Spectral Measurements T oolkit User Guide 26 ni.com A veraging Options Figure 10 illustrat es the options av ailable for spectrum averaging. Figure 10. Spectrum A veraging Options The av eraging processes apply weighti ng to the < > operator in both RMS and vector a veraging as shown in the follo wing equation: Y k = < X > k = a 1 × ...

  • National Instruments Toolkit - page 27

    © National Instruments Corporation 27 NI Sp ectral Measurements T oolkit User Guide emphasis on the most recent data. The averages sofar parameter stops incrementing at N while the averaging continues. Linear weighting i ncludes the foll owing modes: • One-shot linear averaging—A ver age one time for the specified duration of N measurements. W ...

  • National Instruments Toolkit - page 28

    NI Spectral Measurements T oolkit User Guide 28 ni.com A veraged Power Spectrum The following equations describe the averaging meth ods you can apply to a complex FFT spectrum to yield an averaged power spectrum. The No averaging method converts the comp lex FFT spectrum to a real power spectrum. The av eraged power spectrum is equiv ale nt to the ...

  • National Instruments Toolkit - page 29

    © National Instruments Corporation 29 NI Sp ectral Measurements T oolkit User Guide A veraged Frequency Response If you have a stimulus to a system with spectrum X and the system response Y , the frequency response H of the system is shown by the following eq uation: Y ou can use the equations shown in the following table to obtain the vector and ...

  • National Instruments Toolkit - page 30

    NI Spectral Measurements T oolkit User Guide 30 ni.com Spectrum scaling options are com binations of the following options: • RMS or peak —An FFT returns an amplitu de spectrum scaled such that a frequency bin represents the RMS v alue of a sine wav e at that frequency . A bin can also represen t the peak v alue if you scale the spectrum by . ? ...

  • National Instruments Toolkit - page 31

    © National Instruments Corporation 31 NI Sp ectral Measurements T oolkit User Guide Peak Search and Amplitu de/Frequency Estimation The SMT Spectrum Peak Sear ch VI uses interpolat ion to precisely locate frequency peaks in the amplitude or power spectrum and to estimate the amplitude of each peak. You can enter a real spectrum in any units or sca ...

  • National Instruments Toolkit - page 32

    NI Spectral Measurements T oolkit User Guide 32 ni.com Power in Band The SMT Power in Band VI, located on the SMT Measurements palett e measures the total power within some frequency rang e or band. X is the input power spectrum in V 2 rms . Perform this measurement before performing unit conversion. Enter a center frequency and bandwi dth in Hz, f ...

  • National Instruments Toolkit - page 33

    © National Instruments Corporation 33 NI Sp ectral Measurements T oolkit User Guide Figure 12 illustrates a typical A CP m easurement and the three parameters that specify the channels. Figure 12. ACP Measurement Occupied Bandwidth (OBW) The SMT Occupied Bandwidth V I, located on the SMT M easurements palette, returns the bandwidth of the frequenc ...

  • National Instruments Toolkit - page 34

    NI Spectral Measurements T oolkit User Guide 34 ni.com Figure 13 shows an e xam ple of an OBW measurement. The logarithmic amplitude scale gi ves the appearance of a signif ican t amount of power outside the channel, but only 1% of the signal power is actually located there. Figure 13. Occupied Bandwidth Measurement Where to Go for Support The Nati ...

  • National Instruments Toolkit - page 35

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or t rade names of their respective companie s . For patents covering Nat ...

Produzent National Instruments Kategorie Tool Storage

Dokumente, die wir vom Produzenten des Geräts National Instruments Toolkit erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen National Instruments
- Bedienungsanleitungen Toolkit
- Produktkarten National Instruments
- Informationsbroschüren
- oder Energieetiketten National Instruments Toolkit
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung National Instruments Toolkit.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen National Instruments Toolkit, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen National Instruments Toolkit. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts National Instruments Toolkit ansehen.

Die komplette Bedienungsanleitung des Geräts National Instruments Toolkit, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von National Instruments Toolkit hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von National Instruments Toolkit verständlich ist.

Eine gänzliche Bedienungsanleitung von National Instruments sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von National Instruments Toolkit bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von National Instruments Toolkit befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich National Instruments Toolkit, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts National Instruments Toolkit - die uns die ersten Schritte während der Nutzung von National Instruments Toolkit erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit National Instruments Toolkit hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von National Instruments Toolkit im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich National Instruments Toolkit?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit National Instruments Toolkit nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit National Instruments Toolkit hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)