Bedienungsanleitung hussman P/N IGUP-AB-0904

27 Seiten 0.74 mb
Download

Zur Seite of 27

Summary
  • hussman P/N IGUP-AB-0904 - page 1

    /Chino AB UPRIGHT MEA T DISPLA Y CASE REV . 0904 Installation & Operation Manual AB UPRIGHT MEA T DISPLA Y CASE P/N IGUP-AB-0904 INST ALLA TION & O PE R A TI O N GUIDE ...

  • hussman P/N IGUP-AB-0904 - page 2

    IGUP-AB-0904 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A ven ue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for futur e r efer ence. THIS BOOKLET CONT AINS INFORMA TION ON: AB Upright Refrigerated Meat Displa y Case SHIPPING D AMAGE All equipment should ...

  • hussman P/N IGUP-AB-0904 - page 3

    Rev. 0904 3 The AB Meat mer chandisers are easy to w ork, attractive merchandising displa y cases capable of maintaining superb product quality , with the installation of the pr oper controlling de vices. These should be set accor ding to the manufactur er’ s specifications and combined with a properly maintained humidity system. Incorr ect setti ...

  • hussman P/N IGUP-AB-0904 - page 4

    IGUP-AB-0904 4 Cut & Plan Views WIRE RACK BALLAST HUMIDITY SYSTEM 28 1/8" 85 5/16" 49" 28" WATER SUPPLY TO HAND VALVE BALLAST & TERMINAL BLOCKS T5 LAMP HUMIDITY SYSTEM DRAIN SLIDING DBL-PANE GLASS DOOR 44.5 " X 54 " ( 44.5 " X 66") BALLAST LOCATION ELECTRICAL 6” 1.2” Komacel walls 28 1/8" 60& ...

  • hussman P/N IGUP-AB-0904 - page 5

    Rev. 0904 5 PER NSF INSTALLATION REQUIREMENT SEAL AROUND C ASE T O BASE PERIMETER W ITH NSF APPROVED SEALANT NSF Installation Requirement ...

  • hussman P/N IGUP-AB-0904 - page 6

    IGUP-AB-0904 6 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A P-trap must be installed to pr e vent air leakage and in- sect entrance into the fixture. (P-traps ar e not supplied with these cases.) NOTE: PVC-DWV solvent cement is reco ...

  • hussman P/N IGUP-AB-0904 - page 7

    Rev. 0904 7 Fr actal Humidity System GENERAL INFORMA TION The Ser vice Case Humidification system is an automatic moisture maintenance system designed to raise humidity lev els in an y new or existing service case counter or re frigerated floral displa y . It deliv ers a damp fog into the ser vice case or floral displa y at selected intervals by us ...

  • hussman P/N IGUP-AB-0904 - page 8

    IGUP-AB-0904 8 ...

  • hussman P/N IGUP-AB-0904 - page 9

    Rev. 0904 9 Recommended operation times: Y ou should adjust your humidification time for your stores needs~ This is because each service case and floral display differs in temperature, humidity , case style and volume. See chart below for sample timings, APPLICA TION OFF TIME ON TIME Seafood 5 min 30 sec Meat 5 min 30 sec. Deli 10 min. 30 sec. Flor ...

  • hussman P/N IGUP-AB-0904 - page 10

    IGUP-AB-0904 10 MODELS “SCH & SCHMS” - EMITTER NOZZLE CLEANING INSTRUCTIONS If the nozzle appears plugged or seems to sputter , it ma y be that some particles or mineral buildup has occurred in the fluid body of orifice. Follow these simple instructions to solv e the pr oblem. Also , depending on the quality of the local water supply , regu ...

  • hussman P/N IGUP-AB-0904 - page 11

    Rev. 0904 11 Humidity System, Cont’ d TROUBLE SHOOTING GUIDE Problem Possible Cause / Remedy Compressor not running • Loss of power to controller . Check 1 10V supply and in-store breaker . • Loss of power to compressor . Check for loose wires on controller module. No Humidity Plume • W ater turned off. Check main water supply to regulator ...

  • hussman P/N IGUP-AB-0904 - page 12

    IGUP-AB-0904 12 Refrigeration REFRIGERANT TYPE The standard r efrigerant will be R-22 unless otherwise specified on the customer order . Check the serial plate on the case for information. REFRIGERA TION LINES LIQUID SUCTION 3/8" O.D. 5/8" O.D. NOTE: The standard coil is piped at 5/8" (suction); however, the store tie-in may vary dep ...

  • hussman P/N IGUP-AB-0904 - page 13

    Rev. 0904 13 Electrical WIRING COLOR CODE Color Description Descripcion Descripcion GROUND TIERRA MASA MASSE ANTI-SWEA T ANTICONDENSCION ANTI-SUINTEMENT LIGHTS LUCES ECLAIRAGE RECEPT ACLES ENCHUFER RECEPT ACLE T -ST A T/SOLENOID 230 V THERMOST A TO / SOLENOID (230 VAC) SOUP APE A SOLENOID (230 V) T -ST A T/SOLENOID 115 V THERMOST A TO / SOLENOID (1 ...

  • hussman P/N IGUP-AB-0904 - page 14

    IGUP-AB-0904 14 User Information NON-GLARE GLASS The high optical clarity of this glas is possible due to sepcial coatings on the glass surface itself. T o preserve this coating and the optical clarity , keep the glass clean. Windex ® or Glass Plus ® ar e the only solutions r ecommended to be used to clean the non-glar e glass. The damage to the ...

  • hussman P/N IGUP-AB-0904 - page 15

    Rev. 0904 15 User Information, Cont’ d ...

  • hussman P/N IGUP-AB-0904 - page 16

    IGUP-AB-0904 16 Maintenance ELECTRICAL PRECAUTIONS BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights. REPLACING FLUORESCENT LAMPS Fluorescent lamps ar e furnished with a shatterpr oof pr o- tect ...

  • hussman P/N IGUP-AB-0904 - page 17

    Rev. 0904 17 Electrical Schematics Date: Project Title: Drawing No.: Drawn By : Assembly: Drawing Titl e: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A . 91710 (909)- 590- 4910 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Locati on: Boris Ka sre l BJK Sh eet of 1 1 06.27.00 H:WireSchematicsNewWiri ...

  • hussman P/N IGUP-AB-0904 - page 18

    IGUP-AB-0904 18 Date: Project Title: Drawing No.: Drawn By : Assembly: Drawing Titl e: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A . 91710 (909)- 590- 4910 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Locati on: Boris Ka sre l BJK S heet of 1 1 06.27.00 H:WireSchematicsNewWiring... 06.27.00 W00 ...

  • hussman P/N IGUP-AB-0904 - page 19

    Rev. 0904 19 Date: Project Title: Drawing No.: Drawn By : Assembly: Dr awing Title: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A . 91710 (909)- 590- 4910 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Locati on: Boris Ka sr el BJK S heet of 07.13.00 H:WireSchematicsNewWiring... final Aged Beef Disp ...

  • hussman P/N IGUP-AB-0904 - page 20

    IGUP-AB-0904 20 Date: Project Title: Drawing No.: Drawn By : Assembly: Drawing Titl e: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A . 91710 (909)- 590- 4910 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Locati on: Boris Ka sre l BJK S heet of 06.29.00 H:WireSchematicsNewWiring... final Aged Beef D ...

  • hussman P/N IGUP-AB-0904 - page 21

    Rev. 0904 21 Date: Project Title: Drawing No.: Drawn By : Assembly: Drawing Titl e: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A . 91710 (909)- 590- 4910 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Locati on: Boris Ka sre l BJK S heet of 06.29.00 H:WireSchematicsNewWiring... final Aged Beef Disp ...

  • hussman P/N IGUP-AB-0904 - page 22

    IGUP-AB-0904 22 Appendix A. – Temperature Guidelines Refrigerated The refrigerators should be operated according to the manufacturer’s published engineering specifications for entering air temperatures for specific equipment applica- tions. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defr ...

  • hussman P/N IGUP-AB-0904 - page 23

    Rev. 0904 23 data which, coupled with other observations, may be used to determined whether a display refrigerator is working as intended: a) INSTRUMENT – A stainless steel stem-type ther- mometer is recommended and it should have a dial a minimum of 1 inch internal diameter. A test thermometer scaled only in Celsius or dually scaled in Celsius a ...

  • hussman P/N IGUP-AB-0904 - page 24

    IGUP-AB-0904 24 f) Minimize the transfer time of perishables from storage to display. g) Keep meat under refrigeration in meat cutting and processing area except for the few moments it is being handled in processing. When a cut or tray of meat is not to be worked on immediately, the procedure should call for returning it to refrigera- tion. h) Keep ...

  • hussman P/N IGUP-AB-0904 - page 25

    Rev. 0904 25 ...

  • hussman P/N IGUP-AB-0904 - page 26

    IGUP-AB-0904 26 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann merchandisers ar e war ranted to be free fr om defect in material and w orkmanship under normal use and ser vice for a period of one (1) y ear fr om the date of original installation (not to exceed fifte ...

  • hussman P/N IGUP-AB-0904 - page 27

    Rev. 0904 27 The MODEL NAME and SERIAL NUMBER is required in or der to provide y ou with the correct parts and information for y our particular unit. They can be found on a small metal plate on the unit. Please note them below for futur e refer ence. MODEL: SERIAL NUMBER: /Chino Additional copies of this publication ma y be obtained b y contacting: ...

Produzent hussman Kategorie Kitchen Utensil

Dokumente, die wir vom Produzenten des Geräts hussman P/N IGUP-AB-0904 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen hussman
- Bedienungsanleitungen P/N IGUP-AB-0904
- Produktkarten hussman
- Informationsbroschüren
- oder Energieetiketten hussman P/N IGUP-AB-0904
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung hussman P/N IGUP-AB-0904.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen hussman P/N IGUP-AB-0904, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen hussman P/N IGUP-AB-0904. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts hussman P/N IGUP-AB-0904 ansehen.

Die komplette Bedienungsanleitung des Geräts hussman P/N IGUP-AB-0904, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von hussman P/N IGUP-AB-0904 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von hussman P/N IGUP-AB-0904 verständlich ist.

Eine gänzliche Bedienungsanleitung von hussman sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von hussman P/N IGUP-AB-0904 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von hussman P/N IGUP-AB-0904 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich hussman P/N IGUP-AB-0904, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts hussman P/N IGUP-AB-0904 - die uns die ersten Schritte während der Nutzung von hussman P/N IGUP-AB-0904 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit hussman P/N IGUP-AB-0904 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von hussman P/N IGUP-AB-0904 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich hussman P/N IGUP-AB-0904?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit hussman P/N IGUP-AB-0904 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit hussman P/N IGUP-AB-0904 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)