Bedienungsanleitung Goodman Mfg GDS8

16 Seiten 0.23 mb
Download

Zur Seite of 16

Summary
  • Goodman Mfg GDS8 - page 1

    GDS8 & GHS8 33-3/8" 80% Gas Furnace Unit s • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page 3. RT6622011 S ...

  • Goodman Mfg GDS8 - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician&qu ...

  • Goodman Mfg GDS8 - page 3

    3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. * These models available in Low NOx The United States Environmental Protection Agency (“EPA”) has issued various regulations re- gardin ...

  • Goodman Mfg GDS8 - page 4

    4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system. ...

  • Goodman Mfg GDS8 - page 5

    5 PRODUCT DIMENSIONS MO D EL A B G H S 80 453 A XC* 14 1/ 2 " 1 2 1/ 2" GH S 80 7 04 B X C * 17 1 / 2 " 1 6" GH S 80 9 05 C X C * 21" 1 9 1/ 2" MO D EL A B G D S 80 453 A XC* G D S 80 703 A XC* GD S 80 9 04 B X C * 17 1 / 2 " 1 6" GD S 81 1 55 C X C * 21" 1 9 1/ 2" 14 1/ 2 " 1 2 1/ 2" ...

  • Goodman Mfg GDS8 - page 6

    6 PRODUCT DESIGN GHS8 For installations in Canada, the GHS furances are certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GHS 804 53A XC* 2 GHS 807 04B XC* 2 GHS 809 05C XC* 2 R O LL O U T L IMI T SW IT C H ES P art N u m b er 0130F00038 O p en Se t ...

  • Goodman Mfg GDS8 - page 7

    7 PRODUCT DESIGN GDS8 Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GDS 804 53A XC* 2 GDS 807 03A XC* 2 GDS 809 04B XC* 2 GDS 811 55C XC* 2 R O LL O U T L IMI T SW IT C H ES M od e l P a r t N o . O pe ns * G DS804 53A X C * B13 70142 - 0. 60 G DS807 03A X C * B1 37158 - 0. 70 G DS809 04B X C * B13 70142 - 0.60 G DS811 55C X C * B1 37158 ...

  • Goodman Mfg GDS8 - page 8

    8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GHS8 furnaces, in horizontal applications and for the GDS8 for downflow applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 80% furnaces match up with the existin ...

  • Goodman Mfg GDS8 - page 9

    9 PRODUCT DESIGN Thermost at s: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow ...

  • Goodman Mfg GDS8 - page 10

    10 PRODUCT DESIGN Counterflow Filters "A" Min Return Air Opti onal Ac ce ss Door This furnace has provisions for the installation of return air filters at the counterflow top return. The furnace will accommodate the following filter sizes depending on cabinet size: Refer to Minimum Filter Area tables to determine filter area requirement. ...

  • Goodman Mfg GDS8 - page 11

    FURNACE SPECIFICA TIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above ...

  • Goodman Mfg GDS8 - page 12

    FURNACE SPECIFICA TIONS Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above 20 ...

  • Goodman Mfg GDS8 - page 13

    13 BLOWER PERFORMANCE SPECIFICA TIONS GHS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as high-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION ...

  • Goodman Mfg GDS8 - page 14

    BLOWER PERFORMANCE SPECIFICA TIONS 14 GDS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION I ...

  • Goodman Mfg GDS8 - page 15

    15 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 9 0 11 0 12 0 100 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 OUTP UT BTU/H R x 10 00 BTU OUTPUT vs T EM PERATURE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 1600 1800 2000 220 0 240 0 C F M FORMULAS BTU OUT PUT = CFM x 1. 08 x RI SE RISE = BTU O UTP UT 1.0 8 ÷ CF M ...

  • Goodman Mfg GDS8 - page 16

    16 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH . G*S8 B O X ...

Produzent Goodman Mfg Kategorie Gas Heater

Dokumente, die wir vom Produzenten des Geräts Goodman Mfg GDS8 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Goodman Mfg
- Bedienungsanleitungen GDS8
- Produktkarten Goodman Mfg
- Informationsbroschüren
- oder Energieetiketten Goodman Mfg GDS8
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Goodman Mfg GDS8.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Goodman Mfg GDS8, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Goodman Mfg GDS8. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Goodman Mfg GDS8 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Goodman Mfg GDS8, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Goodman Mfg GDS8 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Goodman Mfg GDS8 verständlich ist.

Eine gänzliche Bedienungsanleitung von Goodman Mfg sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Goodman Mfg GDS8 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Goodman Mfg GDS8 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Goodman Mfg GDS8, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Goodman Mfg GDS8 - die uns die ersten Schritte während der Nutzung von Goodman Mfg GDS8 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Goodman Mfg GDS8 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Goodman Mfg GDS8 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Goodman Mfg GDS8?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Goodman Mfg GDS8 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Goodman Mfg GDS8 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)