    1 1-800-352-5630 www .raritaneng. com IMPOR T ANT SAFETY I NSTRUCTIONS FOR HANDLING PURASAN ® T ABLETS AND SOLUTION W ARNING: HAZARD OF DANGEROUS CHEMICAL REACTION 1. Use ONL Y Purasan T ablets. 2. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P . - Cleans Potties and R.C. Raritan Concentrate ...

  • Raritan Engineering PST*03 - page 2

    2 OPERA TION (depends on installation chosen) Single Button operation - Both toilet and Purasan are operated by one of the following options: Option #1: Switch Panel "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will mome ...

  • Raritan Engineering PST*03 - page 3

    3 MAINTENANCE Use ONLY Purasan Tablets. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P. - Cleans Potties and R.C. Raritan Concentrate are the only factory-recognized cleaning products that may be used in the toilet. MAINTENANCE WARNING: Read and understand all safety instructions (including Ma ...

  • Raritan Engineering PST*03 - page 4

    4 WINTERIZING T ablet Dispenser 1. Close flow metering clamp and disconnect power to water solenoid, if used, to prevent intake wa- ter from entering tablet dispenser . 2. Flush toilet and activate treatment cycle several times to leave just water in tank. 3. Carefully remove small tube from white “T” fitting or check valve from water solenoid ...

  • Raritan Engineering PST*03 - page 5

    5 RECOMMISSIONINGST ART -UP Recommissioning IMPOR T ANT :  Do not load T ablet Cartridge into Dispenser until system is powered and operational.  Do Not Operate Purasan until T reatment Unit is filled with water . T reatment T ank 1. Reconnect hoses and open seacocks. 2. Reconnect wires and turn power on. NOTE: Purasan treatment tank must be ...

  • Raritan Engineering PST*03 - page 6

    6 SPECIFICA TIONS U.S.C.G. Type I MSD Certification #159.015/106/0 Maximum Roll/Pitch Angle: 30° Maximum Temperature Exposure: 120° F (49° C) Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush) Water - fresh, salt or brackish CONVERSIONS Wire - A WG to mm 2 Feet to Meters t e e F 0 15 10 25 20 30 40 5 r e t e M 1 . 36 . 41 . 66 . 72 ...

  • Raritan Engineering PST*03 - page 7

    7 INST ALLA TION MOUNTING T reatment T ank W ARNING: DO NOT locate in an ar ea where ambient temperature exceeds 120 o F (49 o C). 1 . Locate top of treatment tank at or below discharge of toilet and within six feet (1.5 m). Note: If mounting treatment tank higher than discharge. Contact Raritan 2 . Make and secure mounting frame to flat surface. 3 ...

  • Raritan Engineering PST*03 - page 8

    8 INST ALLA TION Raw Water Toilets - 1. T urn off power to toilet. 2. Close intake and discharge seacocks and drain water from toilet system. 3. Disconnect intake hose from bowl elbow . 4. Remove existing bowl elbow and install new bowl elbow supplied with Purasan. 5. Insert the “T” fitting in the hose between the output of the pump and the new ...

  • Raritan Engineering PST*03 - page 9

    9 WIRING WIRING W ARNING: Hazard of Shock and Fire • Always use proper wire, wir e connectors and fuse/circuit br eaker . See Specification Chart. • Secure wir e properly . • Do not connect other appliances to Purasan circuit. • Make sure power is off before proceeding. • Improper wiring can damage the Circuit Board and void warranty . NO ...

  • Raritan Engineering PST*03 - page 10

    10 WIRING Flushing Option #1: "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will momentarily flush the toilet. 1. Mount Switch Panel near toilet. CAUTION: Use only the Raritan #CDS (fail- ure to do so will damage to the C ...

  • Raritan Engineering PST*03 - page 11

    11 TROUBLESHOOTING TROUBLESHOOTING W ARNING: After the tablet dispenser has had water added, it contains a very strong halogen solution. Always wear protective gloves and ventilate well to work on tablet dispenser . Before doing any maintenance or repairs, follow WINTERIZING/STORAGE pr ocedures No Water to tablet dispenser • Clogged check valve ( ...

  • Raritan Engineering PST*03 - page 12

    12 EXPLODED P ARTS 10 17 18 8 7 21 63 64 56 43 45 6 42 43 47 49 32 31 29 28 53 23 55 50 23 23 24 22 41-100 ...

  • Raritan Engineering PST*03 - page 13

    13 EXPLODED P ARTS PURASAN PARTS LIST Item Part # Description 50 41-110 Vent Kit for Tablet Dispenser (Incl. #53, 54, & 55) 51 M3 1 #14 Brass Flat Washer (4) 52 M3 0 1/4"-20 Brass Nut (4) 41-100 Tablet Dispenser Complete (less cartridge) 41-200 T-Fitting (Incl. #33, 34, 37 &38) 42-1000 Treatment Unit Complete 12 V DC 43-1000 Treatment ...

  • Raritan Engineering PST*03 - page 14

    14 DUAL INSTALLATION - “Push Button” also activates Purasan - PBS Battery 3 amp Fuse Small post on CDS to S2 and PBS CDS T o toilet positive (+) Purasan Circuit Board on T reatment tank Freshwater Solenoid valve wiring Battery DUAL INST ALLA TION IMPOR T ANT :  Dual toilet installations requir e either independant operation of toilet and tre ...

  • Raritan Engineering PST*03 - page 15

    15 NOTE: Discharge of raw , untreated sewage is prohibited in all U.S. waters inside the thr ee mile limit except in the Gulf of Mexico where the limit is nine miles. "Y" valves, if installed, must dir ect toilet discharge to a U.S.C.G. approved treatment system or holding tank and must be secur ed in that position while inside the three- ...

  • Raritan Engineering PST*03 - page 16

    16 L405 0911kgs S pecifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 Website: www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 Mark (2) Mounting Holes Level Ac ...

Fabricante Raritan Engineering Categoría Marine Sanitation System

Los documentos del dispositivo Raritan Engineering PST*03 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Raritan Engineering
- manuales de instrucciones PST*03
- hojas de producto Raritan Engineering
- folletos informativos
- o etiquetas energéticas Raritan Engineering PST*03
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Raritan Engineering PST*03.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Raritan Engineering PST*03, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Raritan Engineering PST*03. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Raritan Engineering PST*03.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Raritan Engineering PST*03, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Raritan Engineering PST*03. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Raritan Engineering PST*03.

El manual de instrucciones completo de Raritan Engineering debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Raritan Engineering PST*03 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Raritan Engineering PST*03, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Raritan Engineering PST*03 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Raritan Engineering PST*03 - que deben facilitarnos los primeros pasos durante el uso de Raritan Engineering PST*03
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Raritan Engineering PST*03
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Raritan Engineering PST*03 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Raritan Engineering PST*03?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Raritan Engineering PST*03, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Raritan Engineering PST*03 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)