Manual de instrucciones Furuno 1715

48 de páginas 2.4 mb
Descargar

Pasar a la página of 48

Summary
  • Furuno 1715 - page 1

    MARINE RAD AR MODEL 1715 OPERA T OR'S MANU AL www .fur uno .co .jp MODEL Back ...

  • Furuno 1715 - page 2

    i Ni-Cd Pb IMPORT ANT NOTICES General • The operator o f this equipment must read and follow the descriptions in t his manual. Wr ong operation or maintenance can cancel the w ar ranty or cause injury . • Do not copy any part of this m anual without written permission from FURUNO. • If this manual is lost or worn, contact your dealer about re ...

  • Furuno 1715 - page 3

    ii SAFETY INSTR UCTIONS Safety Instructions for the Operator WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar antenna mast. Do not disassemble or mo ...

  • Furuno 1715 - page 4

    iii COMP LI A NCE WIT H R&TTE D IRECT I VE 1999/ 5/EC This radar complies with the R&TTE Directive 1999/5/EC. In accordance with Article 6- 3 of t his directive, FURUNO intends to put this radar on the market of the following countries in EU as well other markets. Austria, Belg ium, Cyprus, Denmark, Estonia, Finland, France, Germany , Greec ...

  • Furuno 1715 - page 5

    iv T ABLE OF CONTENTS FORE WORD ................................................v SYSTEM CONFIG URA TION .......................vi EQUIP MENT L ISTS ...................................vii 1. OPERA TION ........................................... 1 1.1 Controls .................................................. 1 1.2 Indica tions ................... ...

  • Furuno 1715 - page 6

    v FOREWORD A Word to the Owner of the MODEL 1715 Congratulations on your choice of the FURUNO MODEL 1715 Marine Radar . For over 60 years FURUNO Electric Company has en j oyed an env iable r eputation for innovative and dependable marine electronics equipment. This dedication t o excellence is furthered by our extensive global network of agent s an ...

  • Furuno 1715 - page 7

    vi SYSTEM CONFIGURA TION DISPLA Y UNIT RDP-142 EXTERNAL BUZZER XH3-BZ-L970 SHIP'S MAINS 12-24 VDC RECTIFIER PR-62 : Standard supply : Optional supply : Local supply SHIP'S MAINS 100/1 10/1 15/220/230 V AC , 1 φ , 50/60 Hz NA VIGA T OR or ECHO SOUNDER (NMEA 0183) ESC MENU MODE VRM EBL GAIN ALARM RANGE GPS RECEIVER GP-310B/320B WIND INDICA ...

  • Furuno 1715 - page 8

    vii EQUIPMENT LISTS S tandard supply Name T ype Code No. Qty Remar ks Antenna Unit RSB-0095- 076 — 1 Disp lay Unit RDP-1 42 — 1 CP03-2530 1 008-442-280 1 set Antenna un it inst. material s CP03-2491 0 000-080-231 Antenna ca ble (10 m) T ype: MJ-A10SPF0003- 100 Code No. : 000-129-609 CP03-2492 0 000-080-232 Antenna ca ble (15 m) T ype: MJ-A10SPF ...

  • Furuno 1715 - page 9

    1 1. OPERA TION 1.1 Controls Cursor Pad Chooses menu items; adjusts VRM, EBL and cursor . Opens/closes menu; escapes from current operation. Sets to TX or ST-BY. Chooses display mode. Opens dialog box for adjustment of gain, A/C SEA, A/C RAIN. Chooses radar range. Enables/disables guard alarm. T urns EBL on/off. Short press: Turns power on. Long pr ...

  • Furuno 1715 - page 10

    1. OPERA TION 2 1.2 Indicati ons TRAIL G(IN) ES H IR H FTC 2 6 nm ZOOM Range Range ring inter val Zoom Echo trails Guard alar m (IN or OUT) Echo stretch Rain clutter suppressor Guard zone Cursor EBL Range rings Range, bearing and time-to-go to cursor location (Cursor latitude and longitude position also av ailable if r adar is interf aced with a na ...

  • Furuno 1715 - page 11

    1. OPER A TION 3 1.3 T ur ning Powe r On/Off Press the [POWER/B RILL] key to tu rn on the power . The unit beeps, the s tartup screen appears, and then the e quipm ent checks the ROM and RAM f or proper operation and displays program number . The ROM and RAM check shows OK or NG (No Good). If NG appears, try to press any key except the [POWER/BRI L ...

  • Furuno 1715 - page 12

    1. OPERA TION 4 1.5 Adju sti ng Display Co nt rast , Brillian ce 1. W ith the power turned on, press the [POW ER/BRI LL] key mom entari ly to show the brillia nce /co nt rast a dju stme nt wi ndow . CONT: 4 LOW HIGH BRILL: LOW HIGH 9 BRILL/CONTRAST TX/ST-BY - PRESS [MODE] [MENU/ESC] : Exit. Brillian ce / co nt rast a dju stme n t w i ndow 2. Press ...

  • Furuno 1715 - page 13

    1. OPERA TION 5 M a nual gain adjustm e nt W hile obser ving the sc reen and the gain tuning bar , press ◄ or ► to adjust the gain. The setting r ange is 0- 100. 3. Press the [M ENU/ESC] key to finish. 1.8 Suppressi ng Sea Clutter Echoes from waves cov er the central part of the display with random signals known as s ea clutter . The higher the ...

  • Furuno 1715 - page 14

    1. OPERA TION 6 M a nual A /C SE A a djustm e nt W hile obser ving the scr een and the A/C SEA tuning bar , press ◄ or ► to adjust the A/C SEA. The setting r ange is 0-100. 3. Pr ess the [MEN U/ESC] key to finish. 1.9 Suppressi ng Rain Cl utter The ver tical beamwi dth of the antenna is designed to s ee surface targets even when the ship i s ro ...

  • Furuno 1715 - page 15

    1. OPERA TION 7 1.1 1 M easuring the Bearing The bearing to a t arget c an be measur ed with the curs or and the EBL (El ectroni c Bearing Line) . Measu rin g bearin g with the cu rsor Operate the curs or pad to pl ace the curs or on the center of the tar get. Read the beari ng to the t arget at the bottom ri ght corner . Measu rin g bearin g with ...

  • Furuno 1715 - page 16

    1. OPERA TION 8 1. 13 Zoom The zoom f eature al lows y ou to double the siz e of a select ed area. I f zoom i s activated w hen nav data i s displ ayed, the nav dat a is automati call y eras ed. 1. U se the curs or pad to pl ace the curs or wher e you want to zoom . 2. Press the [M ODE] key to s how the display mode m enu. DISPLA Y MODE [MENU/ESC] ...

  • Furuno 1715 - page 17

    1. OPERA TION 9 User menu desc ription It em Descri pt ion TX/ST - BY Sets r adar i n tr ansm i t or stand-b y status. ( Sam e f uncti ons as t he [MO DE] k ey .) INT REJE CTIO N Rej ects r adar i nter f erenc e. ECHO ST RET CH S tr etches echoes i n r ange dir ecti on or rang e and b ear ing dir ecti on. FTC Supp r ess es long - rang e r ain clutt ...

  • Furuno 1715 - page 18

    1. OPERA TION 10 1.17 Noise R ejector The noi se reject or suppres ses whi te noise, whi ch appears on the s creen as m any dot s scatter ed randoml y over the di splay . 1. Pr ess the [M ENU/ESC ] key to open the User menu. 2. Press ▲ or ▼ to choos e NOI SE REJE CTI ON from p age 1. 3. Press ► to open the options w indow . 4. Press ▲ or ? ...

  • Furuno 1715 - page 19

    1. OPERA TION 11 1.20 Guard Alar m The guar d alarm allows the operator to set the desi red range and bear ing for a guard zone. W hen ship s, isl ands, landmas ses, etc. viol ate the guard zone, audi o and visual alar ms are r eleased to cal l your attention. The ala rms will be rele ase d f or targ ets enteri ng or exiti ng the zone depending on ...

  • Furuno 1715 - page 20

    1. OPERA TION 12 1.21 Watchman How watchman works W atchman transmi ts the radar f or one m inute to check if a target has entered or exi ted the guard z one f rom the pr evious tr ansmi ssion. I f no change is f ound, the radar goes into stand- by for the number of mi nutes set for the watchm an f eature. I f change i s f ound, the audio al arm so ...

  • Furuno 1715 - page 21

    1. OPERA TION 13 1.24 Hue The default hue setti ng (DA Y ) displ ays echoes i n tones of gray on a white backgr ound, which i s most s uit able f or daytim e viewi ng. For ni ghttime vi ewing you may r everse thi s arr angement. 1. Pr ess the [M ENU/ESC ] key to open the User menu. 2. Press ▼ to choose SY STEM M ENU. 3. Press ▲ or ▼ to choos ...

  • Furuno 1715 - page 22

    1. OPERA TION 14 1.28 T urning Navigation D at a On/Off Navi gation data appear s on the bottom half of the scr een as in the illustra tio n b elow . Y o u may tur n the navigati on data dis play on or off as show n below . No te : W hen the nav data i s turned on w ith shift or zoom active, zoom or shift is cancel led. 1. Press the [M ODE] key . 2 ...

  • Furuno 1715 - page 23

    1. OPERA TION 15 GRAPHIC DISPLAYS DIGITAL DISPLAYS 1 0.5 0 0.5 1 Waypoint 03 Rng 0.19nm Brg 321 ° XTE 0.00nm Cse 333 ° DESTINA TION WA YPOINT GRAPHIC XTE scale Bearing, Course Destination waypoint direction Destination waypoint data: Name, Range to, XTE Wind APP* WIND GRAPHIC 60 120 90 0 30 150 180 120 150 90 60 30 120 ° Speed 10.3 m/s COMP ASS ...

  • Furuno 1715 - page 24

    1. OPERA TION 16 1.30 System M enu The Sys tem menu m ainly c ontai ns items whi ch once set do not requi re frequent adjustm ent. Y ou may di splay thi s menu by choosi ng “SY STEM M ENU” f rom page 2 of the User menu and then pr essing ► . SYSTEM MENU LANGUAGE English RANGE UNIT : nm DEPTH UNIT : ft SPEED UNIT : kt WIND UNIT : kt TEMP UNIT ...

  • Furuno 1715 - page 25

    1. OPERA TION 17 P A N EL D IM M ER, H UE, TRI PLOG RESET : See par agraph 1.23, 1.24, 1.25, respec tively . Pa g e 2 o f syste m men u EBL REFERE N CE : The EBL readout may be chosen from relative ( relati ve to own ship’ s heading) or true ( referenced to the Nor th). Headi ng data r equired for tr ue bearing. No te : If no bearing dat a is i n ...

  • Furuno 1715 - page 26

    18 2. MAI NTENANCE, TRO UBLESHO OT ING WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. 2.1 M aintenance Regul ar mai ntenance is i mport ant f or good per f orm ance. A mai ntenance progr am should be est ablis hed and should at least i nclude the i tems li sted in the t able bel ...

  • Furuno 1715 - page 27

    2. MAINTENANC E, T ROU BLESHOOTING 19 2.2 Rep l acing the F use The fuse (5 A) i n the power cabl e protect s the equipm ent against r everse polar ity of the ship’ s mai ns, overc urrent, and equi pment f ault. I f the f use blows , f ind the caus e bef ore r eplacing i t. Use the proper fuse. Use of a wrong fuse may cause serious damage to the ...

  • Furuno 1715 - page 28

    2. MAINTENANC E, T ROU BLESHOOTING 20 2. 4 Di agnos ti cs I f you feel that your uni t is not wor king proper ly , conduct the appr opriate di agnostic test, dis play unit or antenna unit, to find the possi ble cause. I f you cannot restor e normal operati on, contac t your dealer f or advi ce. Di sp la y unit 1. T urn on the power whil e pressi ng ...

  • Furuno 1715 - page 29

    2. MAINTENANC E, T ROU BLESHOOTING 21 ANTENNA ST A TUS : OK(47)# HEADING : OK BEARING : OK (24.0r pm)* TUNE : T OT AL ON TIME : 00000h T O T AL TX TIME : 00000h INPUT NMEA RMA RMB RMC BWC GLL GGA MTW VTG VHW XTE VBW DPT DBK DBS DBT HDT HDG HDM BWR GLC GTD MWV ZD A # Numeric is status code. F or ser vice technician. * Antenna rotation speed 24.0 = L ...

  • Furuno 1715 - page 30

    22 3. INST ALLA TION NO TICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic par ts, especially plastic connectors. 3.1 A ntenna Unit Insta llation Mounting considerations W he n choosing a mounting location for the ant ...

  • Furuno 1715 - page 31

    3. IN ST ALLA TION 23 3. U se the f lat w ashers and s pring was hers rem oved earl ier and appr opriate hex bol ts (see the illust rat ion b elo w) to f ast en t he antenna unit to the pl atform. The torque shoul d be betwee n 19 .6-2 4.5 N / / / / m . Flat washer Antenna base assy. Spring washer Platform Hex bolt (M10 x 25 or M10 x 20) Apply sili ...

  • Furuno 1715 - page 32

    3. INST ALLA TION 24 8. T ighten the cabl e gland to fix the antenna cable. Gasket Cable Gland T ighten gland so this length is within 12 mm. Antenna unit, i nside vi ew 9. R ef err ing to the f igur e below , fasten the shiel d cable w ith a scr ew (M 4 x 10) on the chass is to ground the uni t. Connect 9 pin connector here (J801). Connect shield ...

  • Furuno 1715 - page 33

    3. IN ST ALLA TION 25 Mounting plate Suppor t plate (1) Suppor t plate (2) Brac ket (1) Brac ket (2) Fixing plate M8 x 20 M8 x 20 (A) Assembling the mounting brac ket M4 x 12 (B) Fastening antenna to mounting brac ket M10 x 25 M8 x 20 How to assem ble the optional mounting brac ket and mount the antenna 4. Open the cover . 5. Follow step s 5-13 in ...

  • Furuno 1715 - page 34

    3. INST ALLA TION 26 3.3 W iri ng Connect the antenna c able, the power cable and the ground w ire as shown below . FUSE (5 A) PO WER SUPPL Y 12/24 VDC PO WER CABLE DISPLA Y UNIT ANTENNA UNIT ANTENNA CABLE * WHT (+) BLK (-) External Equipment (NMEA) GROUND Connect ground wire to bolt f astened (or welded) to hull. * = Do not confuse the antenna cab ...

  • Furuno 1715 - page 35

    3. IN ST ALLA TION 27 Conn ecting the exter nal buzzer The opti onal external buzzer ( type XH3- BZ-L970, code no. 000- 146-422) sounds the alar m buzzer in a rem ove location. No te : Thi s procedur e requi res mak ing a hole in the di splay unit, w hich can affect wate rtig htn ess. FURUNO c annot guarantee water tight integri ty after thi s modi ...

  • Furuno 1715 - page 36

    3. INST ALLA TION 28 6. Press ► to show the R adar Setup menu. RAD AR SETUP HEADING ADJUST TIMING ADJUST SET ON TIME : 000000h SET TX TIME : 000000h [MENU/ESC]: Exit. Radar setup menu 7. HEADING ADJUS T is se lected ; press ► to show the opti ons wi ndow . RAD AR SETUP HEADING ADJUST TIMING ADJUST SET ON TIME : 000000h SET TX TIME : 000000h [ME ...

  • Furuno 1715 - page 37

    3. IN ST ALLA TION 29 3. Press ▲ to choose YES, and the di splay now l ooks as below . SWEEP TIMING ADJUSTMENT BY ’ ’ AND ’ ’ KEYS. THEN PUSH MODE KEY TO SET . Message Ti ming adjus tment displ ay 4. F ind a tar get whic h should be “s traight” (har bor wal l, str aight pier ) on the radar displa y . 5. W hile l ooking at the t arget ...

  • Furuno 1715 - page 38

    3. INST ALLA TION 30 3.5 Magnetron H eater V olt age M agnetron heater volt age is formed at the M D Board of the antenna unit and i s preadj usted at the f actor y . Ther ef ore, no adjustm ent is requi red. How ever , veri f y the volt age as below . WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. DO NOT attempt the procedure below unl ...

  • Furuno 1715 - page 39

    31 M ENU TREE MENU/ESC key + POWER/BRILL key SIMULATION ( OFF , ON, HIGH) TEST (Tests display unit.) LCD PATTERN (Displays test pattern.) MEMORY CLEAR (Restores default menu settings.) NMEA PORT ( IN/OUT, IN/IN) NMEA OUTPUT ( OFF , ON) GPS WAAS ( OFF , WAAS 00-27) GO TO RADAR SETUP HEADING ADJUST (Adjusts heading.) TIMING ADJUST (Adjusts timing.) S ...

  • Furuno 1715 - page 40

    SP- 1 E3514S01B SPECIFI C ATIONS O F MARINE RADAR MOD EL 1715 1 GENE R AL 1.1 Indicati on Syst em PPI da ylig ht di sp lay , rast er s can, 4 to nes i n m onoc hrom e 1.2 Range ( show n: nm ), Pulsel eng th ( PL) & Pul se R epet iti on Rat e (PR R) Rang e 0.125 , 0. 25, 0.5, 0.75 1, 1.5 , 2 3, 4, 6, 8, 12, 16, 24, 36 Puls e Leng th 0.08 μ s ( ...

  • Furuno 1715 - page 41

    SP-2 E3514S01B 4.4 Mark ers Headi ng Line, B ear ing Sc ale, R ang e Ri ngs , V ar iab l e Rang e Mar ker ( VRM) , El ectr onic Beari ng Line (EBL) , Cur sor, Alarm Zone, Wayp oint M ar k* 4.5 Alp hanum er ic Indi cati ons Rang e, R ang e Ri ng Inter v al, I nterf er ence R ej ecti on (IR ) , V ar iab l e Rang e Mar ker ( VRM) , El ectr onic Beari ...

  • Furuno 1715 - page 42

    Y. Hatai D-1 ...

  • Furuno 1715 - page 43

    Takahashi T . Y. Hatai OUTLINE DRAWING D-2 ...

  • Furuno 1715 - page 44

    Takahashi T . Y. Hatai OUTLINE DRAWING D-3 ...

  • Furuno 1715 - page 45

    Takahashi T . Y. Hatai OUTLINE DRAWING D-4 ...

  • Furuno 1715 - page 46

    A B C 2 3 1 4 MASS kg SCALE APPROVED CHECKED DRAWN DWG.No. TITLE 名称 NAME 03-165-6001-0 REF.No. 相互結線図 MODEL 1715 MARINE RADAR INTERCONNE CTION DIAGRAM 船舶用レーダー T.YAMASAKI NOTE 注記 *4)空中線部のシールドは完全に アースする。 *5) ( ): MJ-A10SPF0009の芯線色 を示す。 *1)造船所? ...

  • Furuno 1715 - page 47

    ...

  • Furuno 1715 - page 48

    The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 A : AUG 2003 . Printed in Japan All rights reserved. C3 : MAR . 03, 2011 Pub. No. OME-35140-C3 *00014790912* *00014790912* ( YOSH ) MODEL1715 * 0001 ...

Fabricante Furuno Categoría Marine RADAR

Los documentos del dispositivo Furuno 1715 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Furuno
- manuales de instrucciones 1715
- hojas de producto Furuno
- folletos informativos
- o etiquetas energéticas Furuno 1715
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Furuno 1715.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Furuno 1715, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Furuno 1715. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Furuno 1715.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Furuno 1715, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Furuno 1715. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Furuno 1715.

El manual de instrucciones completo de Furuno debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Furuno 1715 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Furuno 1715, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Furuno 1715 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Furuno 1715 - que deben facilitarnos los primeros pasos durante el uso de Furuno 1715
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Furuno 1715
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Furuno 1715 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Furuno 1715?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Furuno 1715, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Furuno 1715 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)