Manual de instrucciones Superior B-40REP

16 de páginas 0.47 mb
Descargar

Pasar a la página of 16

Summary
  • Superior B-40REP - page 1

    1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS ST ANDARD SERIES 36" B-VENTED GAS APPLIANCES P/N 700,003M REV. H 05/2004 Millivolt Models Electronic Models B-40RMN B-40REN B-40RMP B-40REP RET AIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No. J20006722 MODELS FOR YOUR SAFETY: Do not store or use gasoline o ...

  • Superior B-40REP - page 2

    2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Location .......................................... page 3 Clearances ....................................... page 3 Appliance Specifications .................. page 4 Ga ...

  • Superior B-40REP - page 3

    3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi- ately. Turn off the gas supply to the appliance and have it serviced by a qualified profes- sional, as it may not be ...

  • Superior B-40REP - page 4

    4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.4 mm) of a vertical wall or similar obstruction. Gas vent caps that are located 8' or more from a portion of a building which extends at an angle greater than 45 ° upward from the horizontal may terminate in accordan ...

  • Superior B-40REP - page 5

    5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. A 38 ¹⁄₂ " 978 mm B 33 ³⁄₄ " 857 mm C 28 ³⁄₁₆ " 716 mm D 14" 356 mm E 55" 1397 mm F 27 ¹⁄₂ " 699 mm G 13 ¹⁄₂ " 343 mm H 38 ⁷⁄₈ " 987 mm FRAMING SPECIFICATIONS Figure 4 Figure 5 Figure 6 Figure 7 Framing Dimensions PRE-INSTALLA ...

  • Superior B-40REP - page 6

    6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 10 Note: Refer to the vent manufacturers installa- tion instructions for variations of venting tech- niques. If common venting of several units is contemplated, it should be discussed with an architect and the local Building Department. CAUTION: THIS APPLIANCE CANNOT BE VENTED HORIZONTALLY. ...

  • Superior B-40REP - page 7

    7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 13 Figure 14 Figure 12 Figure 15 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resis- tant compounds are used in propane applica- tions). Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for lea ...

  • Superior B-40REP - page 8

    8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: DO NOT REMOVE THE AC- TUATOR ARM LOCKING SCREW UNLESS THE COMPLETE OUTSIDE AIR VENT SYS- TEM HAS BEEN INSTALLED IN ACCOR- DANCE WITH THE DETAILED INSTRUC- TIONS PROVIDED WITH THE KIT. Figure 16 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, howev ...

  • Superior B-40REP - page 9

    9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 19 Figure 20 When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the in- struction manual. APPLIANCE OPERATION Step 9. Checking the System – With gas line in ...

  • Superior B-40REP - page 10

    10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates prop- erly, proceed to finish the installation. Leave the control knob/lever in “ ON ” position and turn the remote switch “ OFF. ” Replace the refractory access panel. Figure 24 Adjustment To adjust the flame, position the air shutter to the nomi ...

  • Superior B-40REP - page 11

    11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTALLATION ACCESSORIES The following accessory items are available for use in the installation of this appliance. Outside Air Kits Models FOAK-4 and FOAK-4LD Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired. If ...

  • Superior B-40REP - page 12

    12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE. LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORI ...

  • Superior B-40REP - page 13

    13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 29 Pilot Orifice Step 6. All Millivolt Systems – Attach ma- nometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. Step 7. Refer to Figure 29 and rem ...

  • Superior B-40REP - page 14

    14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. ...

  • Superior B-40REP - page 15

    15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. ...

  • Superior B-40REP - page 16

    16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 700,003M REV. H 05/2004 LHP 1110 West Taft Avenue • Orange, CA 92865 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and pr ...

Fabricante Superior Categoría Indoor Fireplace

Los documentos del dispositivo Superior B-40REP que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Superior
- manuales de instrucciones B-40REP
- hojas de producto Superior
- folletos informativos
- o etiquetas energéticas Superior B-40REP
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Superior B-40REP.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Superior B-40REP, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Superior B-40REP. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Superior B-40REP.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Superior B-40REP, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Superior B-40REP. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Superior B-40REP.

El manual de instrucciones completo de Superior debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Superior B-40REP - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Superior B-40REP, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Superior B-40REP que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Superior B-40REP - que deben facilitarnos los primeros pasos durante el uso de Superior B-40REP
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Superior B-40REP
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Superior B-40REP en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Superior B-40REP?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Superior B-40REP, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Superior B-40REP probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)