    Manual P/N 820-1552-EN Rev . B 1261-7203-00 SIGNALING LISTED U L A TTENTION: Please take a few minutes to thoroughly r ead this user’ s guide which should be saved for future r eference and passed on to any subsequent owner . Smoke Alarm User’ s Guide • 120 V olt Smoke Alarm with 9 V olt Battery Back-up • Front Load Battery • T est and Hu ...

  • Firex i4648A - page 2

    Smoke Alarm Procedur e NEVER IGNORE THE SOUND OF THE ALARM! Smoke alarms are designed to minimize false alarms. Cigar ette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles fr om cook- ing may set off the alarm if it is located too close to the cook- ing area. Large quantities of comb ...

  • Firex i4648A - page 3

    A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke Alarm with 9 V olt Battery Back Up and HUSH TM Control to temporar- ily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’ s home safety plan. Y ou can trust this product to provide the highest quality safety pr ...

  • Firex i4648A - page 4

    W ARNING! REMOV AL OF THE SMOKE ALARM BA TTER Y AND DISCONNECT- ING or LOSS OF A.C. POWER WILL RENDER THE SMOKE ALARM INOPERA TIVE. ELECTRICAL RA TING: 120 V AC, 60HZ, 80mA maximum per alarm (maximum 80mA for originating unit with 24 devices interconnected). 1. RECOMMENDED LOCA TIONS FOR ALARMS • Locate the first alarm in the immediate area of th ...

  • Firex i4648A - page 5

    • Install Smoke Alarms on tray-shaped ceilings (coffer ed ceilings) on the highest portion of the ceiling or on the sloped portion of the ceiling within 12” (305mm) verti- cally down from the highest point (see figur e 4). MOBILE HOME INST ALLA TION Modern mobile homes have been designed and built to be energy efficient. Install smoke alarms as ...

  • Firex i4648A - page 6

    • In dusty areas. Dust particles may cause nuisance alarm or failur e to alarm. • In very humid areas (gr eater than 85% R.H.). Moisture or steam can cause nuisance alarms. • In insect-infested areas. • Smoke alarms should not be installed within 3 ft (.9m) of the following: the door to a kitchen, the door to a bathroom containing a tub or ...

  • Firex i4648A - page 7

    • When alarms are inter connected, all interconnected units must be powered from a single cir cuit. • A maximum of 24 Kidde and/or FireX devices may be inter connected in a mul- tiple station arrangement. The interconnect system should not exceed the NFP A interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxid ...

  • Firex i4648A - page 8

    BA TTERY INST ALLA TION See MAINTENANCE (Section 6) for battery installation. CAUTION! THIS UNIT WILL NOT FUNCTION WITHOUT A PROPERL Y INST ALLED BA TTERY , AND IS EQUIPPED WITH A BA TTER Y LOCKOUT FEA- TURE WHICH PREVENTS THE BA TTERY DOOR FROM CLOSING IF A BA T- TER Y IS NOT INST ALLED CORRECTL Y . MOUNTING INSTRUCTIONS CAUTION: THIS UNIT IS SEAL ...

  • Firex i4648A - page 9

    NOTE: The alarm will mount to the bracket in 4 positions (every 90 degrees). When wall mounting, make sure the battery box is at the bottom of the unit. (see Figure 5). 6. Pull the Battery Pull T ab (red tab pr otruding from the unit) completely out of the unit unit and slide the battery door completely closed. This will automatically connect the b ...

  • Firex i4648A - page 10

    4. OPERA TION AND TESTING OPERA TION: The smoke alarm is operating once A.C. power is applied, fresh batteries are installed and testing is complete. When the smoke alarm ionization chamber senses products of combustion, the horn will sound a loud (85db) tem- poral alarm until the sensing chamber is cleared of smoke particles. HUSH TM CONTROL: The ...

  • Firex i4648A - page 11

    Alarm Memory: This smoke alarm is equipped with an alarm memory , which provides a visual indication when an alarm has been activated. The red LED will illuminate for about 1.5 seconds every 16-20 seconds to indicate the memory condition. The memory will remain activated until pushing the T est/Hush Button resets it or will time-out between 11 to 1 ...

  • Firex i4648A - page 12

    6. MAINTENANCE / TROUBLESHOOTING ALARM REMOV AL I F SMOKE ALARM T AMPER RESIST FEA TURE HAS BEEN ACTIVA TED, REFER TO SMOKE ALARM T AMPER RESIST FEA TURE IN SECTION 3 FOR REMOV AL INSTRUCTIONS. T o remove the alarm fr om the trim ring, rotate the alarm counter clockwise in the direction of the "OFF" arr ow on the cover . T o disconnect th ...

  • Firex i4648A - page 13

    BA TTERY REPLACEMENT . Carbon-zinc type EVEREADY 1222; GOLD PEAK 1604P OR 1604S Alkaline type ENERGIZER 522; DURACELL MN1604 OR MX1604; GOLD PEAK 1604A P ANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA) Lithium type UL TRALIFE U9VL-J These batteries can be purchased at your local retailer . NOTE: WEEKL Y TESTING IS REQUIRED! WARNING! BE SURE TO ...

  • Firex i4648A - page 14

    tially fatal fires. Victims are often intimate with the fir e, too old or young, or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible. For these people, other strategies such as protection-in-place or assisted escape or r escue are necessary . • Smoke alarms are devices that ...

  • Firex i4648A - page 15

    escape routes fr om each room. Second story windows may need a rope or chain ladder . • Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. • Determine a place outside your home where you all can meet if a fir e occurs. • Familiarize everyone with the sound of the smoke alarm and train them to leav ...

  • Firex i4648A - page 16

    - Leaving children unsupervised. - Cleaning with flammable liquids, such as gasoline. - Fires wher e the victim is intimate with a flaming initiated fire; for example, when a person's clothes catch fire while cooking. - Fires wher e the smoke is prevented from reaching the detector due to a closed door or other obstruction. - Incendiary fires ...

  • Firex i4648A - page 17

    This equipment should be installed in accordance with the National Fir e Protection Association’ s Standar d 72 (NFP A, Batterymarch Park, Quincy , MA 02269). NOTIFY YOUR LOCAL FIRE DEP ARTMENT AND INSURANCE COMP ANY OF YOUR SMOKE ALARM INST ALLA TION. 11. CAUTION (AS REQUIRED BY THE CALIFORNIA ST A TE FIRE MARSHAL) “Early warning fire detectio ...

  • Firex i4648A - page 18

    FIVE YEAR LIMITED W ARRANTY (i4618A, i4718A Series) Kidde warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free fr om defects in material and workmanship or design under normal use and service for a period of five years from the date of pur chase. The obligation of Kidde under this warranty is limited t ...

  • Firex i4648A - page 19

    TEN YEAR LIMITED W ARRANTY (i5000A Series) Kidde warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free fr om defects in material and workmanship or design under normal use and service for a period of ten years from the date of pur chase. The obligation of Kidde under this warranty is limited to repairin ...

Fabricante Firex Categoría Smoke Alarm

Los documentos del dispositivo Firex i4648A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Firex
- manuales de instrucciones i4648A
- hojas de producto Firex
- folletos informativos
- o etiquetas energéticas Firex i4648A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Firex i4648A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Firex i4648A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Firex i4648A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Firex i4648A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Firex i4648A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Firex i4648A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Firex i4648A.

El manual de instrucciones completo de Firex debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Firex i4648A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Firex i4648A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Firex i4648A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Firex i4648A - que deben facilitarnos los primeros pasos durante el uso de Firex i4648A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Firex i4648A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Firex i4648A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Firex i4648A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Firex i4648A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Firex i4648A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)