Manual de instrucciones Smith Cast Iron Boilers 19A SERIES

12 de páginas 0.26 mb
Descargar

Pasar a la página of 12

Summary
  • Smith Cast Iron Boilers 19A SERIES - page 1

    19IOM-5 WESTCAST, INC. 260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799 INST ALLER READ THESE INSTR UCTIONS CAREFULL Y . THEY WILL SA VE TIME IN ASSEMBLING BOILER 19A SERIES BOILER INST ALLA TION INSTR UCTIONS STEAM OR W A TER HEA TING PRESSURIZED FOR FIRING OIL, GAS OR COMBINA TION GAS/OIL DESIGNED AND TESTED ACCORDI ...

  • Smith Cast Iron Boilers 19A SERIES - page 2

    PAGE 2 19A SERIES BOILER INST ALLA TION INSTRUCTIONS — 3640 Bur ner Mounting Plate, P o werflame - 9 1 / 8 " Opening 13 60023 Bur ner Mounting Plate Rope, 1 / 4 " 14 60434 Bur ner Mounting Plate Insulating Block 14 60430 Bur ner Mounting Plate Insulating Block (Beck ett Burner) 15 60331 Upper P ort Hydronic Seal 16 60332 Lower P or t Hy ...

  • Smith Cast Iron Boilers 19A SERIES - page 3

    3. CODES AND REGULATIONS All work in connection with the boiler, burner and controls must be performed in strict accordance with requirements of state and local authorities having jurisdiction over boiler installations. FIGURE 1 In the absence of such local requirements, the following should govern: A.S.M.E. Section IV - “ Heating Boilers" A ...

  • Smith Cast Iron Boilers 19A SERIES - page 4

    CAUTION Due to the fact that the sections are top heavy, it is absolutely necessary that the back section be supported in such a manner as to prevent its falling and causing potential serious bodily injury while preparing to add the next section. One such way would be to insert a piece of 3" x 36" piping in the lower port. NOTE Some secti ...

  • Smith Cast Iron Boilers 19A SERIES - page 5

    2. Water Boilers – The assembled boiler shall be subjected to a hydrostatic test pressure not less than 1-1/2 times the maximum allowable working pressure. 3. The required test shall not exceed the test pressure by more than 10 PSI. Excessive torque on draw rods may damage castings. Do not exceed the torque shown in TABLE 3. In a cold environment ...

  • Smith Cast Iron Boilers 19A SERIES - page 6

    TABLE 5 Feed water makeup requirements. NOTE These recommendations are considered normal for compact buildings on the basis of 80% receiver use. Where buildings are spread out, additional receiver capacity may be necessary because of the extended time required for condensation to return to the receiver. 9. WATER PIPING See FIGURE 5 for acceptable w ...

  • Smith Cast Iron Boilers 19A SERIES - page 7

    FIGURE 6 — TANKLESS PIPING FIGURE 7 — DUAL TANKLESS PIPING 12. BURNER MOUNTING PLATE & TARGET WALL The new target wall used on 3-6 section boilers must be positioned with the flat side tight against the rear casting and with the bottom side resting on the floor of the combustion chamber. No glues or fasteners are used to secure the target w ...

  • Smith Cast Iron Boilers 19A SERIES - page 8

    19A SERIES BOILER INST ALLA TION INSTRUCTIONS PAGE 8 15. CONTROL LOCATIONS NOTE Jacket front panel should be in place before controls on front of front section are installed. Refer to FIGURE 11 showing locations recommended for steam and water boiler limit and operating controls. Note the requirement for an operating temperature control whenever a ...

  • Smith Cast Iron Boilers 19A SERIES - page 9

    19A SERIES BOILER INST ALLA TION INSTRUCTIONS 19. OWNERS INSTRUCTIONS A . For best performance of the boiler, the following suggestions should be performed by a qualified boiler room technician, through a regular program of maintenance and adjustment to obtain the following. 1. Oil burner combustion: 12 to 12 1/2 + % CO2, zero smoke, smooth lightof ...

  • Smith Cast Iron Boilers 19A SERIES - page 10

    19A SERIES BOILER INST ALLA TION INSTRUCTIONS FIGURE 11 PAGE 10 “A” - 1" TAP, PRESSURE CONTROLS “B” - 1 1/4" TAP, STEAM SAFETY VALVE “C” - 1" TAP, OPTIONAL LWCO “D” - 3/4" TAP “A” “B” VENT CONNECTION 3/4" TAP STD. 3" “A” 4" TAP CLEANOUTS 3" RETURN TAP NORMAL STEAM WATER LINE OPTION ...

  • Smith Cast Iron Boilers 19A SERIES - page 11

    19A SERIES BOILER INST ALLA TION INSTR UCTIONS vision problems loss of muscle control weakness dizziness headaches nausea W ARNING shortness of breath unclear thinking unconsciousness Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of producing carbon monoxide (CO). Carbon Monoxide (CO) is a gas which is odorles ...

  • Smith Cast Iron Boilers 19A SERIES - page 12

    WESTCAST, INC. 260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799 ...

Fabricante Smith Cast Iron Boilers Categoría Boiler

Los documentos del dispositivo Smith Cast Iron Boilers 19A SERIES que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Smith Cast Iron Boilers
- manuales de instrucciones 19A SERIES
- hojas de producto Smith Cast Iron Boilers
- folletos informativos
- o etiquetas energéticas Smith Cast Iron Boilers 19A SERIES
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Smith Cast Iron Boilers 19A SERIES.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Smith Cast Iron Boilers 19A SERIES, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Smith Cast Iron Boilers 19A SERIES. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Smith Cast Iron Boilers 19A SERIES.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Smith Cast Iron Boilers 19A SERIES, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Smith Cast Iron Boilers 19A SERIES. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Smith Cast Iron Boilers 19A SERIES.

El manual de instrucciones completo de Smith Cast Iron Boilers debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Smith Cast Iron Boilers 19A SERIES - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Smith Cast Iron Boilers 19A SERIES, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Smith Cast Iron Boilers 19A SERIES que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Smith Cast Iron Boilers 19A SERIES - que deben facilitarnos los primeros pasos durante el uso de Smith Cast Iron Boilers 19A SERIES
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Smith Cast Iron Boilers 19A SERIES
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Smith Cast Iron Boilers 19A SERIES en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Smith Cast Iron Boilers 19A SERIES?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Smith Cast Iron Boilers 19A SERIES, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Smith Cast Iron Boilers 19A SERIES probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)