    L23952Y 1-05 INST ALLA TION, OPERA TION, & MAINTENANCE F AN COIL AIR CONDITIONERS Supersedes: Form 1 15.20-NOM2 (1 199) Form 1 15.20-NOM2 (105) ***** W ARNING TO INST ALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non authorized factory parts voids all warranty or implied warranty and may result in adverse ...

  • York YHBC - page 2

    YORK INTERNA TIONAL 2 FORM 1 15.20-NOM2 (105) 3 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) T ABLE OF CONTENTS UNIT SIZE CFM 3 300 4 400 5 500 6 600 8 800 10 1000 12 1200 13 1300 16 1600 20 2000 T ABLE 1 - NOMINAL AIRFLOWS FIG. 1 – DETERMINA TION OF RIGHT -HAND / LEFT -HAND REFERENCES LD04775 NOTE: Use direction of airow for sel ...

  • York YHBC - page 3

    YORK INTERNA TIONAL 2 FORM 1 15.20-NOM2 (105) 3 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) RECEIVING Material in this shipment has been inspected at the fact ory and relea sed to the tra nsp ort atio n a genc y i n good condition. When received, a visual inspection of all cartons should be made immediately . Any evidence of rough ha ...

  • York YHBC - page 4

    INST ALLA TION 4 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 5 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) FIG. 2 – HORIZONT AL UNITS - TYPICAL WIRING              ? ...

  • York YHBC - page 5

    INST ALLA TION 4 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 5 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) T334 THERMOST A T Heat-Off Cool, Fan Auto-On, 24V , Manual changeover , 4-W ire Thermostat (R, G, Y , W) Adj. Heat Anticipator , Fixed Cooling Anticipator , Fan Cycling (Cooling) or (Heating/Cooling), No Heating Required. T404 T ...

  • York YHBC - page 6

    INST ALLA TION 6 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 7 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) Prior to connecting to the fan coil, all external piping must be purged of debris. When connecting piping or valve kits to fan coil units, do not bend or reposition the coil header tubing for align ment purposes . This could cau ...

  • York YHBC - page 7

    INST ALLA TION 6 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 7 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) V AL VE CLUSTER 2-W ay Motorized V alve Assemblies 1. The moto riz ed valve asse mbly shou ld be at tach ed to the supply header , which is the connection nearest the air outlet ange on the unit. 2. Prior to soldering the joi ...

  • York YHBC - page 8

    INST ALLA TION 8 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 9 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) NOM. CFM (100's) 3, 4, 5, 6, 8, 10 or 13 Unit Style Y - Ceiling Concealed YP - with return plenum & lter YR - recessed w/telescoping panel YC - cabinet exposed Coil Conguration 3 = 2 Pipe Coil, 3 Row 4 = 2 Pipe Co ...

  • York YHBC - page 9

    INST ALLA TION 8 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 9 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) Ceiling Concealed Model with Insulated Return Plenum and Filter – MODEL YPHBC . PHYSICAL DIMENSIONS - INCHES MODEL A B C D E FIL TER SIZE 3YPHBC 24 22 20-1/8 30-1/8 27-1/4 10 X 24 X 1 4YPHBC 30 28 26-1/8 36-1/8 33-1/4 10 X 30 ...

  • York YHBC - page 10

    INST ALLA TION 10 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 1 1 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) CEILING EXPOSED CABINET – MODEL YCHBC             ...

  • York YHBC - page 11

    INST ALLA TION 10 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 1 1 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) All 1-1/2" dia. K.O.;s * 4-Pipe system only NOTES: 1. T elescoping panel allows the cabinet to be installed to within 2 inches of the ceiling line. 2. T elescoping access panel shipped as seperate item. 3. YRHBC units ar ...

  • York YHBC - page 12

    INST ALLA TION 12 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 13 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) 6 Y HHS - 6.0 - 240 - 3 - RH NOM. CFM (100's) 3,4,6,8,10 or 12 Unit Style Y - basic unit YP - with insulated return plenum Motor T ype HH - PSC Motor HHS - SP Motor Coil Connections (looking with airow , from blower en ...

  • York YHBC - page 13

    INST ALLA TION 12 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 13 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM2 (105) Ceiling Concealed Model with Electric Heat, Insulated Return Plenum and Filter – MODEL YPHH           ? ...

  • York YHBC - page 14

    INST ALLA TION 14 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 15 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) FEA TURES: 1. Manual air vents 2. 4-speed direct drive motors 3. 1/2" copper tubing 4. Primary and secondary condensate drains on one end 5. 120/1/60Hz. motors (2) 6. 3-row and 6-row models available 7. Rubber isolation grommets 8. Insu ...

  • York YHBC - page 15

    INST ALLA TION 14 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) 15 YORK INTERNA TIONAL FORM 1 15.20-NOM2 (105) F AN COILS ST ART - UP CHECKLIST Fan INSPECTION - The fan should be inspected and cleaned, in conjunction with maintenance of the motor and bearings. It is important to keep the wheel clean in order to avoid imbalance and vibration.  Chec ...

  • York YHBC - page 16

    MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufcient. COIL The coil must be kept clean by any of the following methods. 1. Cleaning with low-pressure compressed air . 2. Flushing or rinsing with water ( ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York YHBC que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones YHBC
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York YHBC
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York YHBC.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York YHBC, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York YHBC. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York YHBC.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York YHBC, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York YHBC. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York YHBC.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York YHBC - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York YHBC, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York YHBC que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York YHBC - que deben facilitarnos los primeros pasos durante el uso de York YHBC
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York YHBC
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York YHBC en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York YHBC?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York YHBC, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York YHBC probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)