    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 36" Wood Burning Fireplaces P/N 850,046M REV. N/C 01/2007 RD-36 HC-36 RD-36-H HC-36-H RDI-36 HCI-36 RDI-36-H HCI-36-H MODELS MERIT ® SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and under- stand t ...

  • Linksys RDI-36-H HCI-36-H - page 2

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction ..................................... page 3 Clearances/Height Requirements ..... page 3 Chimney System .. ...

  • Linksys RDI-36-H HCI-36-H - page 3

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • dry wall • etc. • plywood PRECAUTIONS Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installe ...

  • Linksys RDI-36-H HCI-36-H - page 4

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 2 Chimney Height The total height of your completed fireplace system from the surface the fireplace rests on to the chimney top must not exceed 60' and must also meet minimum height requirements. Refer to the minimum system height chart. LOCATION OF FIREPLACE Carefully select the proper ...

  • Linksys RDI-36-H HCI-36-H - page 5

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Note: Install the hearth extension only as illus- trated. The safety strips should extend from front of the fireplace at least 1 ¹⁄₂ " and should extend to be at least flush with the sides. In the event a wooden support is used to elevate the fireplace above the floor, a “Z” type safe ...

  • Linksys RDI-36-H HCI-36-H - page 6

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 10 Blocking Metal Safety Strips Figure 8 Figure 9 Step 3. Refer to fireplace drawings and specifi- cations on pages 6 and 7 for framing dimensions and details. Frame appliance enclosure as illus- trated in Figures 11 through 14 on page 8. IMPORTANT: UNDER NO CIRCUMST ...

  • Linksys RDI-36-H HCI-36-H - page 7

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Figure 15 Figure 16 Figure 14 Framing Dimensions A 43" 1092 mm B 44 ¹⁄₂ " 1130 mm C 29 ¹⁄₂ " 749 mm D 15 ³⁄₄ " 400 mm E 73" 1854 mm F 36 ¹⁄₂ " 927 mm G 21 ³⁄₄ " 552 mm H 20 ³⁄₄ " 527 mm J 51 ⁵⁄₈ " 1311 mm Framing Dimen ...

  • Linksys RDI-36-H HCI-36-H - page 8

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 4. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face. Use 8d nails or equivalent ( Figure 17 ). Figure 17 Note: The nailing tabs and the area directly behind the nailing tabs are exempt from the clearances d ...

  • Linksys RDI-36-H HCI-36-H - page 9

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Note: If there is a room above ceiling level, firestop spacer must be installed on the bottom side of the ceiling. If an attic is above ceiling level, firestop spacer must be installed on top side of ceiling joist (Figures 21 and 22 ). Figure 21 Figure 22 CHIMNEY 30 ° OFFSET THROUGH FLOOR OR CEILI ...

  • Linksys RDI-36-H HCI-36-H - page 10

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Waterproof Caulk Step 9. Security Chimneys locking bands, Model FLB, may be required if the chimney extends too high above the roof flashing. As a general rule, if the chimney extends more than 6' above the roof flashing, the use of locking bands is advisable to strengthen the ch ...

  • Linksys RDI-36-H HCI-36-H - page 11

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 Using a FTF8-CTDT Chase Termination: Refer to specific installation instructions in- cluded with the FTF8-CTDT chase termination for clearance and installation details. Using a FTF8-CT1 Chase Termination: Refer to specific installation instructions in- cluded with FTF8-CT1 chase terminations for c ...

  • Linksys RDI-36-H HCI-36-H - page 12

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Step 2. Use “Height of Chimney Only” column in The Vertical Elevation Chart to determine combinations of chimney used above return elbow to achieve desired heights. Reference Components Effective Height Chart in vertical elevation chart section. 4. Determine amount of chimney height re- quired ...

  • Linksys RDI-36-H HCI-36-H - page 13

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 A B FTF8-ES30 Number of FTF8 Chimney Sections Offset Height Offset/Return FTF8-S4 (Inches) (Inches) Elbow Stabilizer 12" 18" 38" 48" 41 5 ³⁄₄ 10 0 0 0 0 92 4 ¹⁄₂ 10 1 0 0 0 12 29 ³⁄₄ 10 0 1 0 0 14 ¹⁄₄ 33 ¹⁄₂ 10 2 0 0 0 17 ¹⁄₄ 38 ¹⁄₂ 10 1 1 0 0 ...

  • Linksys RDI-36-H HCI-36-H - page 14

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Figure 43 THIS FIREPLACE IS NOT INTENDED TO BE USED AS A SUBSTITUTE FOR A FURNACE TO HEAT AN ENTIRE HOME. USE FOR SUPPLE- MENTARY HEATING ONLY. HOUSE WIRING COVER PLA TE Replace Cover Plate After Electrical Hook-Up POWER TO THE FIREPLACE The Optional Blower Kit Operates on 115 volt 60 Hz 150 watts ...

  • Linksys RDI-36-H HCI-36-H - page 15

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Figure 44 The FBK-100/200 Blower Kits are design cer- tified by Warnock Hersey for use with these appliances. Always check local building codes. Installation of the FBK Blower Kits must comply with local regulations as well as the National Electric Code. Combustion Air Kits These appliances are eq ...

  • Linksys RDI-36-H HCI-36-H - page 16

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 47 Glass Doors If glass doors are to be installed on these fireplaces, refer to specific installation instruc- tions packed with the glass doors. Use only the doors that are listed for use with these fire- places. Use of other non-listed glass door on these fireplaces may constitute a poten ...

  • Linksys RDI-36-H HCI-36-H - page 17

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 48 A B D C C Hearth Extension Dimensions A 16" B 33" C 8" D 49" Note: To convert inches to millimeters divide by 0.03937 Answer - The minimum required thickness of the Micore 160 is .273”, therefore round up to 1/4” and use the nearest standard thickness available wh ...

  • Linksys RDI-36-H HCI-36-H - page 18

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Secure the hearth extension to the floor to prevent possible shifting. FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like stone, ...

  • Linksys RDI-36-H HCI-36-H - page 19

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 Chimney Section 63L10 FTF8-12 63L13 FTF8-18 63L14 FTF8-36 63L15 FTF8-48 Canadian 62L92 FTF8-18C Chimney Section 62L93 FTF8-36C 63L38 F8F6 Flashing 63L39 F8F12 Firestop Spacer (Flat) 63L31 F8FS-2 Forced Air Blower Kits -Single Speed 80L84 FBK-100 -Variable Speed 80L85 FBK-200 (FBK-200 Models Only) ...

  • Linksys RDI-36-H HCI-36-H - page 20

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Printed in U.S.A. © 2007 by LENNOX HEARTH PRODUCTS P/N 850,046M REV. N/C 01/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fi ...

Fabricante Linksys Categoría Indoor Fireplace

Los documentos del dispositivo Linksys RDI-36-H HCI-36-H que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Linksys
- manuales de instrucciones RDI-36-H HCI-36-H
- hojas de producto Linksys
- folletos informativos
- o etiquetas energéticas Linksys RDI-36-H HCI-36-H
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Linksys RDI-36-H HCI-36-H.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Linksys RDI-36-H HCI-36-H, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Linksys RDI-36-H HCI-36-H. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Linksys RDI-36-H HCI-36-H.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Linksys RDI-36-H HCI-36-H, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Linksys RDI-36-H HCI-36-H. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Linksys RDI-36-H HCI-36-H.

El manual de instrucciones completo de Linksys debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Linksys RDI-36-H HCI-36-H - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Linksys RDI-36-H HCI-36-H, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Linksys RDI-36-H HCI-36-H que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Linksys RDI-36-H HCI-36-H - que deben facilitarnos los primeros pasos durante el uso de Linksys RDI-36-H HCI-36-H
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Linksys RDI-36-H HCI-36-H
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Linksys RDI-36-H HCI-36-H en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Linksys RDI-36-H HCI-36-H?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Linksys RDI-36-H HCI-36-H, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Linksys RDI-36-H HCI-36-H probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)