H8S/2655 Series TQFP-120 User System Interface Cable (HS2655ECN61H) for E6000 Emulator User’s Manual HS2655ECN61HE(C) ...
-
Renesas TQFP-120 - page 2
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property ...
-
Renesas TQFP-120 - page 3
i Preface Thank you for purchasing this user system interface cable (HS2655ECN61H) for the Renesas’s original mi crocomputer H8S/2655 series. The HS2655ECN61H is a user system interface cable that connects an H8S/2655 series E6000 emulator (HS2655EPI61H; hereinafter referred to as the emulat or) to the IC socket for a TQFP-120 package (package co ...
-
Renesas TQFP-120 - page 4
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 4 2.2 Connecti ...
-
Renesas TQFP-120 - page 5
1 Section 1 Configuration CAUTION Use an IC149-120-043-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-120 package IC socket on the user system. Figure 1 shows the configuration of the HS2655E CN61H user system interface cable for the TFP-120 package. ...
-
Renesas TQFP-120 - page 6
Figure 1 HS2655ECN61H User System Interface Cable 2 ...
-
Renesas TQFP-120 - page 7
3 Table 1 lists t he HS2655ECN61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2655ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the TFP-120 package 4 Socket cover 1 For installing a TFP-120 packaged MCU 5 Screws (M2 x 12 mm) 4 For fa ...
-
Renesas TQFP-120 - page 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system a ...
-
Renesas TQFP-120 - page 9
Emulator station E6000 Cable body User system interface cable Figure 2 Connecting User System Int erface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before conne ...
-
Renesas TQFP-120 - page 10
6 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a T FP-120 package to the user system. Be sure to completely solder the leads so that the solder slo p s gently over the leads and fo rms solder fillets. (Use slightly more solder than the MCU.) 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Alig ...
-
Renesas TQFP-120 - page 11
Fasten the user system interface cable head to the IC socket for a TFP-120 package on the user system with t he four screws (M2 x 12 m m; with four flat washers) provi ded. Each screw should be tightened a little at a time, alternating between scre ws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to ...
-
Renesas TQFP-120 - page 12
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8 ...
-
Renesas TQFP-120 - page 13
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for a TFP-120 package (IC149-120-043-B5: m anufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewh at different from those of the actual chip&ap ...
-
Renesas TQFP-120 - page 14
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10 ...
-
Renesas TQFP-120 - page 15
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 ...
-
Renesas TQFP-120 - page 16
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes ...
-
Renesas TQFP-120 - page 17
MCU Pin 1 IC socket (IC149-120-043-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing MCU to User System 13 ...
-
Renesas TQFP-120 - page 18
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2655 series, turn on the emulator according to the procedures described in the H8S Series E6000 Em ulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connec tions by accessing the exte rnal m emory and ports to check the bus states of the pi ...
-
Renesas TQFP-120 - page 19
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifi ...
-
Renesas TQFP-120 - page 20
6. The JP1 jumper connector is used for t esting. Do not remove t he inserted jumper pin. JP1 Figure 11 JP1 Jumper Connector 16 ...
¿Tienes una pregunta acerca de Renesas TQFP-120?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Renesas TQFP-120, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Renesas TQFP-120 probablemente compartirá una forma de solucionarlo.