Manual de instrucciones Vermont Casting 1655, 1656, 1657, 1658, 1659

28 de páginas 0.96 mb
Descargar

Pasar a la página of 28

Summary
  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 1

    1 Vermont Castings Madison Homeowner ’ s Installation and Operating Manual For use in the United States and Canada SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAM ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 2

    2 Vermont Castings Madison Introduction Thank you for choosing a Vermont Castings Madison to meet your heating needs. We're confident you will find the Madison to be an effective woodburning heater incorporating modern, non-catalytic combustion technology with the classic aesthetic appeal of its Vermont Castings lineage. The Madison achieves h ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 3

    3 Vermont Castings Madison Specifications Madison, Model 1655 Series Maximum heat output ......................... 39,700 Btu’s/hr . 1 Area heated ...................................... Up to 1600 sq. ft. 2 Fuel size/type ...................................... 18” (46 cm) logs Loading ..................................................... Front ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 4

    4 Vermont Castings Madison Installation Chimneys Y our stove must be connected either to a sound masonry chimney that meets local codes, to a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney . Whichever of those types you use, the chimney and chimney con- nector must be in good condition and kept clean. ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 5

    5 Vermont Castings Madison Masonry Chimneys, cont'd. • Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Openings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a ch ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 6

    6 Vermont Castings Madison Double-wall Chimney Connectors The Madison is approved for installation in the U.S. and Canada with double-wall chimney connectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory . Follow the instructions for assembling and install- ing double-wall connectors ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 7

    7 Vermont Castings Madison Connection Above the Fireplace In this installation, the chimney connector enters the fireplace flue through a thimble located above the fireplace. (Fig. 6) The liner of the fireplace chimney should extend at least to the point at which the chim- ney connector enters the chimney . Follow all the guidelines for installing ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 8

    8 Vermont Castings Madison Floor Protection A tremendous amount of heat radiates from the bottom plate of your Madison. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox. Heat protection is provided through the use of a V ermont Castings Bo ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 9

    9 Vermont Castings Madison To meet these requirements, a floor protector must be at least 54” (1372mm) wide (“A”,Fig. 12) and 52” (1320mm) deep (“B”, Fig. 12). Fireplace Hearth Protection Do not assume that your fireplace hearth is completely noncombustible. Many fireplace hearths do not satisfy the “completely noncombustible” requi ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 10

    10 Vermont Castings Madison Wall Shields W all shields should be constructed of 24 gauge or heavier sheet metal, or another noncombustible material such as 1/2" (13 mm) insulation board (Fig. 14) or common brick "laid on flat," with the 3 ¹⁄₂ " (90 mm) side down. Shields must be spaced out from the combustible surface 1&quo ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 11

    11 Vermont Castings Madison Alcove Installations Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations. ALCOVE INSTALLATION OF THE MADISON IS NOT PERMITTED IN C ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 12

    12 Vermont Castings Madison Madison 1655 Series Clearance Chart Use the chart below together with the diagrams on the next page to determine the minimum clearance required for your particular installation. In any case, it is always advisable to locate the stove as far away from walls as pos- sible in order to take full advantage of the radiant prop ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 13

    13 Vermont Castings Madison F F C C A B D E J K L L G H P Q M N I I O O R R V W S T U U X X Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner PROTECTED SURFACES Top Exit Installations, no heat shields Top Exit Installations, heat shield on stove, no shields on single-wall connector Top Exit Installati ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 14

    14 Vermont Castings Madison Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner PROTECTED SURFACES Madison 1655 Series Clearance Diagram UNPROTECTED SURFACES Rear Exit Installations, Bottom Heat Shield, floor protection, minimum 18” (457mm) in front. Y Z AA BB EE FF CC DD N / A N / A Rear Exit Install ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 15

    15 Vermont Castings Madison Y ou will need the following tools to assemble the Madi- son: • 9/16" open end wrench • safety glasses & gloves • flat head screwdriver • power drill w/ 1/8" (3mm) bit • stub handle phillips screwdriver Unpack the Stove 1. Remove the shipping straps and plastic wrap. 2. Inspect the stove and conte ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 16

    16 Vermont Castings Madison Attach the Chimney Connector Insert the crimped end of the first section of chimney connector into the flue collar . Using the holes in the collar as guides, drill 1/8" (3mm) holes through the connector pipe. Use the three #10 x 1/2" sheet metal screws provided to secure the chimney connection to the flue colla ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 17

    17 Vermont Castings Madison Operation How the Madison Works Combustion control is achieved in the Madison through two separate air delivery systems. The primary air control lever , located at the left rear corner of the stove, controls the amount of incoming primary air for starting, maintaining, and reviving the fire. More air entering the stove m ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 18

    18 Vermont Castings Madison Fig. 27 Start a fire with small, dry kindling. ST263 Fig. 28 Gradually add larger pieces of wood until all the wood is burning well. ST264 A more effective option for delivering ample combustion air to the stove is to duct air directly from outdoors to the stove. In fact, in some areas, provisions for outside combustion ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 19

    19 Vermont Castings Madison NOTE: Some chimneys need to be “primed,” or warmed up, before they will draw sufficiently to sustain a fire. T o correct this situation, roll up a couple pieces of newspaper , place them on top of the kindling and toward the back of the stove, light them, and close the doors. This should heat the chimney enough to in ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 20

    20 Vermont Castings Madison Maintenance Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Madison looking new. The stove’s paint can be touched up as needed. First, clean the ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 21

    21 Vermont Castings Madison The Chimney System Creosote Your Madison is designed to reduce creosote buildup significantly. However, regular chimney inspection and maintenance must still be performed. For safety, good stove performance, and to protect your chimney and chimney connector, inspect your chimney and chimney connector on a regular schedul ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 22

    22 Vermont Castings Madison Draft Management Your stove is only one part of a system that includes the chimney, the operator, the fuel and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the stove works well. W ood stove operation depends on natural (unforced) draft. Na ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 23

    23 Vermont Castings Madison There should be no more than eight feet of single-wall stove pipe between the stove and a chim- ney . Longer runs can cool the smoke enough to cause draft and creosote problems. Use double-wall stove pipe for longer runs. Single Venting Your stove requires a dedicated flue. Do not connect the stove to a flue used by any ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 24

    24 Vermont Castings Madison 1453 The Vermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 45 44 39 37 36 32 28 27 23 15 4 1 35 8 6 2 12 26 42 30 31 20 19 11 22 3 13 9 21 40 29 17 38 14 7 5 18 10 33 16 43 34 24 25 41 ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 25

    25 Vermont Castings Madison Madison W oodburning Stove Model 1655 (continued) Item Description Part Number 23. Brick Support 30000804 24. Secondary Air Tube (Rear) 30001493 25. Secondary Air Tube (Middle) 30001494 26. Secondary Air Tube (Front) 30001495 27. Friction Spring 1201846 28. Leveller Blt, Hx Hd 1/4-20 x 1” Z 1201745 29. Washer, 1/4 pl 7 ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 26

    26 Vermont Castings Madison ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 27

    27 Vermont Castings Madison 4. This warranty does not cover a stove repaired by someone other than a Vermont Castings Majestic Products Company Authorized Dealer. 5. Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the Authorized Dealer from whom you purchased your Madis ...

  • Vermont Casting 1655, 1656, 1657, 1658, 1659 - page 28

    28 Vermont Castings Madison © Vermont Castings, Majestic Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www.vermontcastings.com Ve r mont Castings, Majestic Products ...

Fabricante Vermont Casting Categoría Stove

Los documentos del dispositivo Vermont Casting 1655, 1656, 1657, 1658, 1659 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Vermont Casting
- manuales de instrucciones 1655, 1656, 1657, 1658, 1659
- hojas de producto Vermont Casting
- folletos informativos
- o etiquetas energéticas Vermont Casting 1655, 1656, 1657, 1658, 1659
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Vermont Casting 1655, 1656, 1657, 1658, 1659.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Vermont Casting 1655, 1656, 1657, 1658, 1659, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Vermont Casting 1655, 1656, 1657, 1658, 1659. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Vermont Casting 1655, 1656, 1657, 1658, 1659.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Vermont Casting 1655, 1656, 1657, 1658, 1659, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Vermont Casting 1655, 1656, 1657, 1658, 1659. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Vermont Casting 1655, 1656, 1657, 1658, 1659.

El manual de instrucciones completo de Vermont Casting debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Vermont Casting 1655, 1656, 1657, 1658, 1659 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Vermont Casting 1655, 1656, 1657, 1658, 1659, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Vermont Casting 1655, 1656, 1657, 1658, 1659 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Vermont Casting 1655, 1656, 1657, 1658, 1659 - que deben facilitarnos los primeros pasos durante el uso de Vermont Casting 1655, 1656, 1657, 1658, 1659
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Vermont Casting 1655, 1656, 1657, 1658, 1659
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Vermont Casting 1655, 1656, 1657, 1658, 1659 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Vermont Casting 1655, 1656, 1657, 1658, 1659?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Vermont Casting 1655, 1656, 1657, 1658, 1659, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Vermont Casting 1655, 1656, 1657, 1658, 1659 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)