Manual de instrucciones Schneider Electric and 6.0A

40 de páginas 2.75 mb
Descargar

Pasar a la página of 40

Summary
  • Schneider Electric and 6.0A - page 1

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Electronic T rip Unit s Unidades de disp aro electrónico Micrologic™ 2.0A, 3.0A, 5.0A y 6.0A Déclencheurs électroniques Micrologic MC 2.0A, 3.0A, 5.0A et 6.0A Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48049-136-05  Rev . 01, 04/2012 Retain for Future Use. /  Cons ...

  • Schneider Electric and 6.0A - page 2

    ...

  • Schneider Electric and 6.0A - page 3

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Electronic T rip Unit s Instruction Bulletin 48049-136-05  Rev . 01, 07/2012 Retain for future use. ENGLISH ...

  • Schneider Electric and 6.0A - page 4

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 2-EN ENGLISH Hazard Categories and Special Symbols Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain i ...

  • Schneider Electric and 6.0A - page 5

    © 1999–2012 Schneider Electric All Rights Reserved 3-EN 48049-136-05 Micrologic ® 2.0A , 3.0A, 5.0A and 6.0A Electronic Trip Units Rev. 01, 07/2012 Table of C ontents ENGLISH Table of Contents SECTION 1: GENERAL INFORMATION .............. .............. ........... .............. .............. .............. .............. .............. ..... ...

  • Schneider Electric and 6.0A - page 6

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Table of Contents Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 4-EN ENGLISH Trip Unit Replacement ......... .............. ................. .............. ................. ....... 29 Battery Installation ....... ................. .............. ...

  • Schneider Electric and 6.0A - page 7

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 1—General Information © 1999–2012 Schneider Electric All Rights Reserved 5-EN ENGLISH Section 1— General Information Communications Micrologic trip units can communicate with other devices if the optional Circuit Breaker Communication Modul ...

  • Schneider Electric and 6.0A - page 8

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 1—General Information Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 6-EN ENGLISH Micrologic 2.0A Tr ip Unit The Micrologic 2.0A trip unit provides basic IEC (LS0) protectio n and a built-in ammeter. A. Trip unit name B. Alphanumeric displ ...

  • Schneider Electric and 6.0A - page 9

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 1—General Information © 1999–2012 Schneider Electric All Rights Reserved 7-EN ENGLISH Micrologic 5.0A Trip Unit The Micrologic 5.0A trip uni t provides selective (LSI) protection and a built-in ammete r. A. Trip unit name B. Alphanumeric disp ...

  • Schneider Electric and 6.0A - page 10

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 1—General Information Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 8-EN ENGLISH Micrologic 6.0A Tr ip Unit The Micrologic 6.0A trip unit provides selective and ground-fault protection for equipment ( d 1200 A) (LSIG) and a built-in am ...

  • Schneider Electric and 6.0A - page 11

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 1—General Information © 1999–2012 Schneider Electric All Rights Reserved 9-EN ENGLISH Zone-Selective Interlocking Short-time and ground-fault protection can be interlocked to provide zone-selective interlocking. Control wiring lin ks several ...

  • Schneider Electric and 6.0A - page 12

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 1—General Information Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 10-EN ENGLISH Trip Unit Switches Long-Time Protection Long-time protection protects equipment against overloads. • Long-time protectio n is standard on all trip units. ...

  • Schneider Electric and 6.0A - page 13

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 1—General Information © 1999–2012 Schneider Electric All Rights Reserved 11-EN ENGLISH Short-Time Protection Short-time protection protects eq uipment against short circuits. • Short-time protection is sta ndard on 2.0A, 5.0A and 6.0A trip ...

  • Schneider Electric and 6.0A - page 14

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 1—General Information Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 12-EN ENGLISH Instantaneous Prot ection Instantaneous protection protects equipmen t against short circu its with no intention al time delay. • Instantaneous protec tio ...

  • Schneider Electric and 6.0A - page 15

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 1—General Information © 1999–2012 Schneider Electric All Rights Reserved 13-EN ENGLISH Indicator Lights Ground-Fault Protection Equipment ground-fault protection protects conductors against overheating and faults from ground-fault currents ( ...

  • Schneider Electric and 6.0A - page 16

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 1—General Information Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 14-EN ENGLISH Trip Unit Testing Trip unit functions can be tested using primary injection testin g or secondary injection testing. Micrologic Trip Unit Configuration Cont ...

  • Schneider Electric and 6.0A - page 17

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 1—General Information © 1999–2012 Schneider Electric All Rights Reserved 15-EN ENGLISH The following will be powere d and functional with external power: • All of the above functions which are functional without external power. • Ammeter ...

  • Schneider Electric and 6.0A - page 18

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 2—Ammeter Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 16-EN ENGLISH Section 2— Ammeter Display NOTE: The ammeter disp lay will function only if the trip unit is powered. The trip unit is powered by the circu it breaker carrying more t ...

  • Schneider Electric and 6.0A - page 19

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 2—Am meter © 1999–2012 Schneider Electric All Rights Reserved 17-EN ENGLISH To access the next menu, press the menu button (A). To access the next screen in a menu, press the scroll button (B). Figure 16: Navigation Buttons Current Menu The c ...

  • Schneider Electric and 6.0A - page 20

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 2—Ammeter Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 18-EN ENGLISH Peak Menu To access the peak menu: 1. Current menu is displayed. 2. Press menu butt on. 3. Peak menu appears. To access menu screens, press scroll button. Figure 18: Ac ...

  • Schneider Electric and 6.0A - page 21

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 2—Am meter © 1999–2012 Schneider Electric All Rights Reserved 19-EN ENGLISH Switch Settings Menu The switch settings menu displays the value s at which the switches are set. To access the switch settings menu: 1. Peak menu is displayed. 2. Pr ...

  • Schneider Electric and 6.0A - page 22

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 3—Operation Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 20-EN ENGLISH Section 3— Operation Switch Setting Adjustment 1. Open switch cover (A). 2. Adjust the appropriate switches (B) to desired values. 3. Replace switch cover. Use wire ...

  • Schneider Electric and 6.0A - page 23

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 3—Operation © 1999–2012 Schneider Electric All Rights Reserved 21-EN ENGLISH 2. Set time delay. Figure 26: Set Time Delay Micrologic 3.0A Trip Unit 1. Set pickup levels. Figure 27: Set Pickup Levels 2. Set time delay. Figure 28: Set Time Dela ...

  • Schneider Electric and 6.0A - page 24

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 3—Operation Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 22-EN ENGLISH 2. Set time delay. Figure 30: Set Time Delays Micrologic 6.0A Tr ip Unit 1. Set pick up levels. Figure 31: Set Pickup Levels 2. Set time delays. Figure 32: Set Pickup ...

  • Schneider Electric and 6.0A - page 25

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 3—Operation © 1999–2012 Schneider Electric All Rights Reserved 23-EN ENGLISH Zone-Selective Interlocking (ZSI) The number of devices which can be interlocked are shown in Table 8. Table 8: ZSI Combinations Micrologic #.0x Trip Units Square D ...

  • Schneider Electric and 6.0A - page 26

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 3—Operation Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 24-EN ENGLISH Wire circuit breakers for zone-selective interlocking. Figure 34: ZSI Wiring Example Communication Module values If the optional circuit breaker commu nication module ...

  • Schneider Electric and 6.0A - page 27

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 3—Operation © 1999–2012 Schneider Electric All Rights Reserved 25-EN ENGLISH Set communication module values: 1. Press and release scroll button to sequence addresses (1 through 47). When the co rrect address number is reache d, enter the val ...

  • Schneider Electric and 6.0A - page 28

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 3—Operation Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 26-EN ENGLISH Trip Unit Settings Check Use the ammeter switch setting menu to check the trip unit settings. 1. Press menu butt on twice. 2. Switch settings menu will appear. 3. Pre ...

  • Schneider Electric and 6.0A - page 29

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 3—Operation © 1999–2012 Schneider Electric All Rights Reserved 27-EN ENGLISH Equipment Ground-Fault Trip Functions Testing Paragraph 230-95 (c) of the National Electri cal Code requires that all equipment gro und-fault protection systems be t ...

  • Schneider Electric and 6.0A - page 30

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 4—Trip Unit Replac ement Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 28-EN ENGLISH Section 4— Trip Unit Replacement Required Tools • Torque-controlled screwdriver, set at 7 in-lbs (0.8 N•m) ± 10% (Lindstrom torque driver MAL500-2 ...

  • Schneider Electric and 6.0A - page 31

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 4—Trip Unit Re placement © 1999–2012 Schneider Electric All Rights Reserved 29-EN ENGLISH Trip Unit Replacement Rating Plug Removal A small Phillips screwdriver i s needed to remove the adjustable rating plug. 1. Open switch cover (A). 2. Uns ...

  • Schneider Electric and 6.0A - page 32

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 4—Trip Unit Replac ement Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 30-EN ENGLISH Trip Unit Installation 1. Inspect trip unit conne ctor pins and surfaces. If there is any damage, misaligned pins, or contamination, stop in stallation a ...

  • Schneider Electric and 6.0A - page 33

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 4—Trip Unit Re placement © 1999–2012 Schneider Electric All Rights Reserved 31-EN ENGLISH Circuit Breaker Accessory Cover Replacement Replace circuit breaker accessory cover as directed in the Install Accessories section of the circuit breake ...

  • Schneider Electric and 6.0A - page 34

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 4—Trip Unit Replac ement Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 32-EN ENGLISH Trip Unit Installation Ch eck Trip Unit Setup 1. If an auxiliary power supply is being used for the Micrologic trip unit, reconnect the auxil iary power ...

  • Schneider Electric and 6.0A - page 35

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 5—Adjustab le Rating Plug Replacement © 1999–2012 Schneider Electric All Rights Reserved 33-EN ENGLISH Section 5— Adjustable Rating Plug Replacement NOTE: To select correct replacement rating plug, see the product catalog. NOTE: If adjustab ...

  • Schneider Electric and 6.0A - page 36

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Section 6—Battery Replacement Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 34-EN ENGLISH Section 6— Battery Replacement Circuit Breaker Disconnection Disconnect circuit breaker as directed in the circuit breaker instruction bul letin shipped w ...

  • Schneider Electric and 6.0A - page 37

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Section 6—Battery Re placement © 1999–2012 Schneider Electric All Rights Reserved 35-EN ENGLISH Circuit Breaker Accessory Cover Replacement Replace circuit breaker accessory cover as directed in the Install Accessories section of the circuit breaker ...

  • Schneider Electric and 6.0A - page 38

    Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0 A Electronic Trip Units 48049-136-05 Appendix A—Register List Rev. 01, 07/2012 © 1999–2012 Schneider Electric All Rights Reserved 36-EN ENGLISH Appendix A—Register List List of Registers The quantities are listed in alphabetical order according to the SMS topic name. NOTE: A system scan rate of 500 ms ...

  • Schneider Electric and 6.0A - page 39

    48049-136-05 Mic rologic™ 2.0A, 3.0A, 5.0A, and 6.0A Elect ronic Trip Units Rev. 01, 07/2012 Append ix A—Register List © 1999–2012 Schneider Electric All Rights Reserved 37-EN ENGLISH TU_BATT_PCT Trip Unit % Battery 1 8843 PM % Unity TU_SN Trip Unit Serial Number 4 8700 PM ASCII text TUCommStatus Trip Unit Internal Comms Status 1 552 BCM Bit ...

  • Schneider Electric and 6.0A - page 40

    Electrical equipment should be instal led, operated, serviced, and maint ained only by qualified personnel. No re sponsibility is assumed by Schneider Electric for an y consequences arising out of the use of this material. Square D™, Schneider Elect ric™, Micrologic™, Modbus, and Masterp a ct™ are trademarks or registered tra demarks of Sch ...

Fabricante Schneider Electric Categoría Gas Grill

Los documentos del dispositivo Schneider Electric and 6.0A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Schneider Electric
- manuales de instrucciones and 6.0A
- hojas de producto Schneider Electric
- folletos informativos
- o etiquetas energéticas Schneider Electric and 6.0A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Schneider Electric and 6.0A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Schneider Electric and 6.0A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Schneider Electric and 6.0A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Schneider Electric and 6.0A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Schneider Electric and 6.0A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Schneider Electric and 6.0A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Schneider Electric and 6.0A.

El manual de instrucciones completo de Schneider Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Schneider Electric and 6.0A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Schneider Electric and 6.0A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Schneider Electric and 6.0A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Schneider Electric and 6.0A - que deben facilitarnos los primeros pasos durante el uso de Schneider Electric and 6.0A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Schneider Electric and 6.0A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Schneider Electric and 6.0A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Schneider Electric and 6.0A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Schneider Electric and 6.0A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Schneider Electric and 6.0A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)