  • Field Controls 10 - page 1

    Installation Guid e Hardware Platform 10 FChwp10 ...

  • Field Controls 10 - page 2

    ...

  • Field Controls 10 - page 3

    Safety Informati on The followi ng are warni ngs or safety guidel ines. A warni ng means dan ger. You are in a situat ion th at could cau se bodil y inju ry. Before you work on any equipment, be aware of the hazards i nvolved wi th electri cal ci rcuitry and be famili ar wi th standard p ractices for preventing acci dents. Qualifi ed Personnel Warn ...

  • Field Controls 10 - page 4

    Restricted Access Area Warning The device is intended for insta llation in restricted access areas. A restricted access area is an area to which access can be gain ed only by service personnel throug h the use of a special too l, lock and key, or other means of security, and t hat is cont rolled by the auth ority responsible for the locati on. Waar ...

  • Field Controls 10 - page 5

    Power Suppl y Disconnecti on Warning Before working on the device or near power supplies, disconnect the pow er. Waarschuwing Voordat u aan een fr ame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker v an het netsnoer uit het stopcontact te halen ; voor g elijkstroom toestellen dient u de stroom uit te schakele ...

  • Field Controls 10 - page 6

    Hardware Platform 10 Installati on Guide 6 Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Q u a l i f i e d P e r s o n n e l W a r n i n g ...................................... 3 I n s t a l l a t i o n W a r n i n g ........................................... ...

  • Field Controls 10 - page 7

    About thi s manua l CER International bv 7 About this manual This document is i ntended for users of the FieldCommand er, ELS- or EWS controllers that are based on the HWP10-platform and explai ns the steps to instal l an d setup the system in your envi ronment. This gu ide contai ns in formation to i nstal l an d configure the uni t i n your netwo ...

  • Field Controls 10 - page 8

    Hardware Platform 10 Installati on Guide 8 Installati on This chapt er explain s the instal l ation in detai l and alon g the way it introduces you to some of the concepts important to understand t he operation of your controller uni t. System require ments In order to connect to the controller, you need a vali d TCP/IP network connection and a bro ...

  • Field Controls 10 - page 9

    Install ation CER International bv 9 LED indicator Next to the Power Connector there is a green LED on the fro nt panel for indi catin g system status. Thi s LED is li t when power is suppl i ed to the unit . Power connector Power to the controller is accommodated by a DC jack “J9” or by passive power over ethernet connector. The DC jack is att ...

  • Field Controls 10 - page 10

    Hardware Platform 10 Installati on Guide 10 (ELS1700 or EWS1700 onl y) VGA Audi o USB (ELS172x only) To be defined !! VGA Audi o USB Serial port The 9-pin port is used to connect your controll er to your serial equi pment. Th e chapter call ed "Serial Interface" uncover s the detail s of ser ial communi cation and pi n-out of the connecto ...

  • Field Controls 10 - page 11

    Install ation CER International bv 11 Hardware instal lation You communi cate with the controller over the Ethernet network. I n thi s part of the chapter, you'll learn about th e uni t itsel f and how and where to connect it. There are no configurabl e parts in side. Everything is controll ed and config ured by the software. Physical installa ...

  • Field Controls 10 - page 12

    Hardware Platform 10 Installati on Guide 12 Power Over Ethernet In your controller a passive power over E thernet (PoE) scheme is impl emented (see below), usi ng the un used pairs of the LAN port for power. Power can be injected usin g passive POE spli tter which can be ordered se perately. P OE Sp l i t t er Fi el dCo mm ande r LAN P OE Pow er ...

  • Field Controls 10 - page 13

    Install ation CER International bv 13 Connecting to the network Before co nnectin g the controll er to the network, yo u mig ht want to consul t your network admin istrator. You can empl oy the controll er at various points i n your ethernet network as shown below. Make sure the IP addres sing scheme of your controller does not interfere with your ...

  • Field Controls 10 - page 14

    Hardware Platform 10 Installati on Guide 14 To connect the CER controller to your 10/100base-T network, you can use any standard Category 5 (CAT5). A sui table cabl e is supp li ed. Attach one side to the RJ- 45 socket marked "Ethernet" on the front panel of the uni t and the other to your ethernet hub or switch. Take note of the ser ial ...

  • Field Controls 10 - page 15

    IP configurati on CER International bv 15 IP configuration Your CER controller uses the common TCP/IP protocols to provide the connection to the cli ent machi ne over Ethernet. Like any serve r or de vice, it needs a 'uni que' IP number to be addressed. This chapter shows the basic concepts necessary to install and operate the controller, ...

  • Field Controls 10 - page 16

    Hardware Platform 10 Installati on Guide 16 For Field Commander controll ers: Assigni ng an IP address on a Field Commander The factory default IP address of the controller is: 10.0.0.1 with netmask 255.0.0.0 . This address wil l suffice when you have a poi nt-to-poi nt connecti on with the controll er or when the local network ID is "10" ...

  • Field Controls 10 - page 17

    IP configurati on CER International bv 17 Note: For se curity reasons, it i s strongly recommended to change thi s password. See the User's G uide for in structions. In case you for got the address of FieldComma nder, you can force it to accept a new IP address by way of ARP and PING commands, see later this chapter. Now you should i denti fy ...

  • Field Controls 10 - page 18

    Hardware Platform 10 Installati on Guide 18 Caution: Be aware that, when your Fi eldComma nder is assign ed a dynamic address, you may not know which ad dress to enter in order to access it. Use this setti ng wi th care. The "System IP" page shows the followin g in formation: IP: I nternet Protocol DHCP: Dynami c Host Configu ration Proto ...

  • Field Controls 10 - page 19

    IP configurati on CER International bv 19 Force new IP address using ARP+PING When Fiel dComman der is outside of your subnet or or you don't recall it's current address, you cannot open the configurati on web pages to change the IP setting s. To solve this, you can force Fiel dCommander to accept a new IP address by way of ARP and PING c ...

  • Field Controls 10 - page 20

    Hardware Platform 10 Installati on Guide 20 For ELS controllers: Assigni ng an IP address on an ELS controlle r The IP address o n an ELS controll er is defined i n a configurat ion fi le and set to 10.0.0.1 by default. To change thi s IP address, connect to the ELS using an US B keyboard, SSH or the ser ial console. Then log i n usi ng username / ...

  • Field Controls 10 - page 21

    IP configurati on CER International bv 21 For EWS controllers: Assigni ng an IP address on an EWS controll er The IP address o n an EWS controll er is defined i n a configu ration fi le and set to 10.0.0.1 by default. To change thi s IP address, connect to the ELS using an US B keyboard, SSH or the ser ial console. Then log i n usi ng username / pa ...

  • Field Controls 10 - page 22

    Hardware Platform 10 Installati on Guide 22 Testing the Etherne t connection The ping test The most basic way to test the network connection i s to do a so-called 'pi ng' test. When the connection i s working, th e CER controller wil l answer with an 'echo' or 'pong'. Start a command prompt on your l ocal machi ne and ...

  • Field Controls 10 - page 23

    Serial interfaces CER International bv 23 Serial interface In this part of the i nstal lati on manu al, you wi ll learn some basics of serial communi cation, th e hardware invol ved and how the CER controll er connects to your RS- 232 device. RS-232 The RS-232c standard The RS-232 stan dard (RS stand s for r ecommended standards ) was publ ish ed f ...

  • Field Controls 10 - page 24

    Hardware Platform 10 Installati on Guide 24 RS-485 (option only) The RS-485 standard The RS-485 commun icati on protocol i s the ind ustry's most widely used bi di rectional , balan ced transmissi on li ne standa rd. It is specifical ly desi gned for indu strial mul ti-d rop systems that shoul d be able to transmi t and receive data at hi gh r ...

  • Field Controls 10 - page 25

    Serial interfaces CER International bv 25 Network topology and wi ring Mult i-drop RS- 485 i mpli es that th ere are two main wires in a segment l abeled DATA + and DATA– or simp le A and B. The wi ring comes as a twisted pair. To reduce e lectrical noise, it sh ould be twi sted as ti ghtl y as possibl e. It is advisabl e to follow the stan dard ...

  • Field Controls 10 - page 26

    Hardware Platform 10 Installati on Guide 26 Automatic Data Flow Control Function for RS-485 The CER controller automat ical ly senses the directi on of incomi ng data an d switch es its transmissi on di rection accordingl y. Therefore no handshaking si gnal (e.g. RTS sig nal) is necessary. This feature lets you simpl y and qui ckly bu il d an RS-4 ...

  • Field Controls 10 - page 27

    Serial interfaces CER International bv 27 Ports on your controll er Hardware Platform 10 has di fferent versions, depending on the model you choose: Model USB* Port 1** Port 2 Port 3 Port 4 ELS1700 2xUSB2.0 RS-232 - - - ELS1722 2xUSB2.0 RS-232 RS -232 - - ELS1724 2xUSB2.0 RS-232 RS -485 - - EWS1700 2xUSB2.0 RS-232 - - - EWS1722 2xUSB2.0 RS-232 RS - ...

  • Field Controls 10 - page 28

    Hardware Platform 10 Installati on Guide 28 - + Pin Assignments RS-232 and RS-485 Serial Ports Pin RS-232 RS-232 full RS-485 Port 1 Port 2/3 (Option only) Port 2 (Opti on only) 1 - DCD DATA– (B) i nvertin g 2 RxD RxD DATA+ (A) non- inverti ng 3 TxD TxD - 4 - DTR - 5 GND GND GND 6 - DSR - 7 - RTS - 8 - CTS - 9 - RI - Power Connector Pin di ameter: ...

  • Field Controls 10 - page 29

    Pin Assi gnment s CER International bv 29 Ethernet pin Col or pair functi on 1 Orange/Whit e 2 TX+ 2 Orange 2 TX- 3 Green/White 3 RX+ 4 Blue 1 POE: VCC in (D C 7-20V) 5 Blue/Wh ite 1 POE: VCC in (D C 7-20V) 6 Green 3 RX- 7 Brown/Whit e 4 POE: GND (power return) 8 Brown 4 POE: GND (power return) USB Ports Pin Si gnal 1 +5V DC 2 D – 3 D + 4 GND ...

  • Field Controls 10 - page 30

    Hardware Platform 10 Installati on Guide 30 VGA Note: In the ELS an Award BIOS is used. The combinati on of Award BIOS and Linux kernel wil l d etect a VGA monitor at bootti me, and won’t boot when no moni tor is connected. Pin Signal 1 VGARed 2 VGAGreen 3 VGABlue 4 nc 5 GND 6 GND 7 GND 8 GND 9 KBVCC +5V 10 GND 11 ncc 12 DDC data 13 HS Hor.Sync 1 ...

  • Field Controls 10 - page 31

    Technical Specifi cati ons CER International bv 31 Technical Specif ications Hardware CPU (type A ) 433MHz AMD Geo de LX700 (type B/C) 500MHz AMD Geo de LX800 Memory (type A) 128 MB SDRAM (type B/C) 256 MB SDRAM Storage (type A/B) 1GB GB Flash drive (256MB rese rved for system) (type C) 4GB GB Flash drive (25 6MB reserv ed for system) Indicators Po ...

  • Field Controls 10 - page 32

    Hardware Platform 10 Installati on Guide 32 RS-485 Interface (option only) Interface one RS-485 ser ial port (EIA/TIA-485 -A, ISO 84 82) Connector D-sub 9 pins Distance 1220 meter max (400 0 feet) Data bits 5, 6, 7 or 8 Stop bits 1, 1½ or 2 Parity Even, Odd, Mark, Space, None Flow control Automatic Signals DATA+ (A), DATA– (B), GND Network Inter ...

  • Field Controls 10 - page 33

    Physical Dimen sions CER International bv 33 Physical D imensions All sizes in millimet ers ...

  • Field Controls 10 - page 34

    Hardware Platform 10 Installati on Guide 34 Notice to the user Regulatory FCC Notice This device complies with Part 15 o f the FCC Rules. Operation is subject to the fo llowing two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including int erference that may cause undesir ...

  • Field Controls 10 - page 35

    Notice to the user CER International bv 35 Declaration of Conf ority Trademarks CER and FieldCommander are registered trademarks of CER International bv. All other product names and ser vices identified throughout this book are trademarks or registered trademark s of their respe ctive companies. They are used throughout this manual in editorial fas ...

  • Field Controls 10 - page 36

    The latest documentati on is available from http://www.cer.com FieldCommander is a pr oduct of: CER International bv Postbus 258 NL 4700 AG Ro osendaal The Netherlands TEL: +31 (0)165 5 5741 7 FAX: +31 (0)165 5 62151 http:// www.cer.com Part no. FCHWP10IG, r evision 3.5.34 ...

Fabricante Field Controls Categoría Network Router

Los documentos del dispositivo Field Controls 10 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Field Controls
- manuales de instrucciones 10
- hojas de producto Field Controls
- folletos informativos
- o etiquetas energéticas Field Controls 10
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Field Controls 10.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Field Controls 10, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Field Controls 10. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Field Controls 10.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Field Controls 10, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Field Controls 10. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Field Controls 10.

El manual de instrucciones completo de Field Controls debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Field Controls 10 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Field Controls 10, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Field Controls 10 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Field Controls 10 - que deben facilitarnos los primeros pasos durante el uso de Field Controls 10
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Field Controls 10
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Field Controls 10 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Field Controls 10?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Field Controls 10, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Field Controls 10 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)