Bryant 359AAV - page 1
1 359AA V 4 - - W A Y MU L TI POISE FIX ED SPE ED CONDENSING GAS FURNACE Ser vice G uide ama CERTIFIED NOTE : Read the en tire in structio n m anu al b efore startin g th e installatio n . . ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD Fai l ure to fol low wa rni ngs c oul d re sul t in pe r sona l inj ury , dea t h, or prope rt y dama ge . Befo re ...
-
Bryant 359AAV - page 2
2 FIRE / EXPLOSION HAZARD Fai l ure t o foll ow this wa r ning coul d c aus e pe rs onal injur y , dea t h, or prope rt y dama ge . Nev er store anyth in g on , n ear, or in con tact w ith the furnace, such as: 1. Spra y or ae ros ol c ans , r ags , br ooms, dus t mops, va c uum cleaners, o r o ther clean in g to o ls. 2. S o ap p ow d ers, b leach ...
-
Bryant 359AAV - page 3
3 7. An ESD se rvi ce ki t (ava i la ble f r om com mer c ia l sour c es ) m a ya l s ob eu s e dt op r e v e n tE S Dd a m a g e . CARE AND MAINTENANCE For c ont inui ng high pe r for ma nce and t o mini miz e poss ibl e equi pme nt fa i lur e , it i s es s ent ia l tha t ma int ena nc e be perf or med annua l ly on this equi pme nt. Consul t your ...
-
Bryant 359AAV - page 4
4 A07691 Center Cli p side- to-sid e 9” (228.6 mm) Fig . 2 - - Botto m F ilter A rran gem ent A07690 Filter Rac k End Cap Fig . 3 - - F ilter In stalled for S id e Inlet f. Remove bl owe r whee l fr om housi ng. UNIT DAMAGE HAZARD Fai l ure to fol low this ca uti on m ay r e sul t in f urna ce c ompone nt failure. The blow er whe e l shoul d not ...
-
Bryant 359AAV - page 5
5 CELL P ANEL BURNERS BURNER BOX MANIFOLD GAS V AL VE A07826 Fig. 4 - - Burner B ox Ass em bly 4. Remo ve w ires from g as valv e. N o te locatio n fo r reassemb ly. 5. Unpl ug ignit e r fr om har nes s . 6. Re move s cr ew s tha t se c ure ma ni fol d to burne r box. (Se e Fi g. 4.) NOTE : Do not re move bur ner box fr om ce l l pane l. 7. Re move ...
-
Bryant 359AAV - page 6
6 Drain T ube Corrugated 5 / 8 ″ ″ (15.9mm) ID & Clamps INLET EXHAUST IN ON OFF V E N T Drain T ube Black Rubber 1 / 2 ″ (12.7mm) ID & Clamps AIR FLOW Street Elbow 1 / 2 ″ (12.7mm) CPVC (Loose parts ba g) Casing Grommet Black Rubbe r (15.9mm) ID (Loose parts b ag) Drain T ee Drain Connect or Black PVC 3 / 4 ″ (18.1mm) PVC X 1 / 2 ...
-
Bryant 359AAV - page 7
7 Plastic Cap Y ellow or black Ve n t D r a i n &C l a m p s INLET EXHAUST IN ON OFF V E N T Casing Grommet Black Rubbe r 5 / 8 ″ (15.9mm) ID (Loose parts b ag) Drain Connect or Black PVC 3 / 4 ″ (19.1mm) PVC X 1 / 2 ″ (12.7mm) CPVC (Loose parts bag) Drain T ube Corrugated 5 / 8 ″ (15.9mm) ID &C l a m p s Coupling & Clamps (Opti ...
-
Bryant 359AAV - page 8
8 EXHAUST AIR FLOW INLET IN ON OFF V E N T Casing Grommet Black Rubber 5 / 8 ″ (15.9mm) CPVC (Loose parts ba g) Drain Connect or Black PVC 3 / 4 ″ (19.1mm) PVC X 1 / 2 ″ (12.7mm) CPVC (Loose parts ba g) 25 - - 24 - - 68 Single Pressure Switch Details Dual Pressure Switch T ee T rap White PVC (loose parts ba g) 2 ″ (50.8mm) PVC Coupling Barb ...
-
Bryant 359AAV - page 9
9 Elbow T ube Black Rubber 1 / 2 ″ ″ ID (13 mm) & Clamps (Loose Parts Bag) AIR FLOW OFF ON AIR FLOW 25 - - 24- - 69 Single Pressure Switch Detail Dual Pressure Switch T ee T rap White PVC (loose parts bag) Flexible T ubing Connector , 3 / 16 ″ (5 mm) OD (loose parts bag) EXHAUS T Cut Here Drain T ube Black, 5 / 8 ″ (16 mm) ID Corrugated ...
-
Bryant 359AAV - page 10
10 AIR FLOW OFF ON Drain Connector Black PVC 3 / 4 ″ CPVC (Loose parts bag) T rap Connection “Clamp ears” Pointed OUT Preassemble & insert into furnace Single Pressure Switch Detail Dual Pressure Switch T ee T rap White PVC (loose parts bag) Drain T ube Corrugated Black, 5 / 8 ″ (16 mm) WA R N I N G Move Caps to top of trap Drain T ube ...
-
Bryant 359AAV - page 11
11 AIR FLOW OFF ON Plastic Caps Y ellow or black Ve n t D r a in &C l a m p s T rap Connection “Clamp ears” Pointed OUT Preassemble & insert into furnace 2 5 -- 2 4 -- 7 0 Single Pressure Switch Detail Dual Pressure Switch T ee T rap White PVC (loose parts bag) Cap and Clamp Open End Flexible tubing connector 3 / 16 ″ (4.8mm) OD (Loos ...
-
Bryant 359AAV - page 12
12 AIR FLOW OFF ON 25 - - 24 - - 70a Single Pressure Switch Detail Dual Pressure Switch T ee T rap White PVC (loose parts bag) W ARNING Move Caps to top of trap Flexible T ube Connector 3 / 16 ″ (4.8mm) OD (Loose Parts Bag) Elbow T ube Black R ubber 1 / 2 ″ (12.7mm) ID & Clamps (Loose Parts Ba g) EXHAUS T Alternate Orientation Field Supplie ...
-
Bryant 359AAV - page 13
13 OFF ON AIRFLOW 3 / 16 ″ (4.8mm) ID Rub- ber T ube Trap Connection “Clamp ears” Pointed OUT Preassemble & insert into furnace 2 5 -- 2 4 -- 7 0 b Single Pressure Switch Detail Dual Pressure Switch T ee T rap White PVC (loose parts bag) W ARNING A d dC a pa n dC l a m p Drain T ube Black Rubber 1 / 2 ″ (12.7mm) ID & Clamps EXHAUS T ...
-
Bryant 359AAV - page 14
14 OFF ON AIR FLOW Coupling & Clamps (Optional) 2 5 -- 2 4 -- 7 0 c Single Pressure Switch Detail Dual Pressure Switch Te e Tr a p White PVC (loose parts bag) Flexible T ubing Connector 3 / 16 ″ (4.8mm) OD (Loose Parts Bag) Barbed Coupling 1 / 2 ″ (12.7mm) OD (Loose Parts Ba g) EXHAUS T Alternate Orientation Field Supplied T ee Cut Here Dra ...
-
Bryant 359AAV - page 15
15 Pr oce dur e 4 — C leaning H eat Excha nge rs The f ol lowi ng it e ms s houl d be per for me d by a qual i fi ed service tech n ician. A. P rima ry H eat E x cha ng ers If heat ex ch ang ers get an accu mu latio n o f ligh t d irt or du st on th e ins i de, they m ay be cl ea ne d by the fol lowi ng proc e dure : NOTE : If h eat exch an gers ...
-
Bryant 359AAV - page 16
16 GAS KET A07828 Fig. 16 - - Gaske t on Colle c tor Box 4. Di sc onne ct pr e ss ur e swi tc h tube s. 5. Di sc onne ct ve nt pi pe fr om induc e r housi ng outle t by loo sen ing clam p. 6. Di sc onne ct dra i n tube fr om induce r housi ng. (See Fi g. 6 - - 14.) 7. Re move induc e r housi ng as s em bly by re moving 4 bolt s attachin g assemb ly ...
-
Bryant 359AAV - page 17
17 1. Conne ct Y -te r mina l i n furna c e as s hown for pr oper bl owe r oper a ti on. 2. Some t her mos ta t s re quir e a “ C” te rmi na l conne ct i on as s hown. 3. If any o f th e or igin al wire, as su p plied , mu st b e repl aced, u se same type or e quiva l ent wi r e. FIEL D 24- - V WIRING FIELD 1 15 - - , 208/230 - - , 460- - V WIR ...
-
Bryant 359AAV - page 18
18 8. Turn o n gas and electrical sup p lies to fu rn ace. 9. V erify ig niter op eration b y in itiatin g furn ace co ntro l self-test fe a tur e or by c ycl ing t he rmos t at . 10. Re pla c e mai n furna c e door . Procedu r e 7 — El ectrical Co ntrols a nd Wiri ng ELECTRICAL SHOCK HAZARD Fai l ure t o foll ow thi s war ning c ould re sul t in ...
-
Bryant 359AAV - page 19
19 UNIT DAMAGE HAZARD Failu re to follow th is caution m ay result in dam age to u n it com ponent s . Mak e sure lim it switch wire d oes n o t con tact an y metallic com ponent s uc h as t he ga s val ve. I f wi re i s shor t ed, the 5- amp fus e on fur na ce cont rol boa r d wi ll ope n and the unit wi ll not oper a te . CAUTION ! A07911 Fig. 19 ...
-
Bryant 359AAV - page 20
20 Fig. 20 - - Wi ri ng Diagr am A07824 359AAV ...
-
Bryant 359AAV - page 21
21 A07825 Fig. 21 - - Servi c e Label 359AAV ...
-
Bryant 359AAV - page 22
22 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. E 2009 Bryan t Heating & Cooling S ystem s D 7310 W . Morris S t. D Indian apolis, IN 46231 Print ed in U.S.A . Edition Date: 05/09 Replaces : NEW Catal og No . SM359AA V --- 0 1 359AAV ...
¿Tienes una pregunta acerca de Bryant 359AAV?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant 359AAV, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant 359AAV probablemente compartirá una forma de solucionarlo.