-
Hearth and Home Technologies L-CORNER-TRC - page 1
1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow t ...
-
Hearth and Home Technologies L-CORNER-TRC - page 2
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas ap ...
-
Hearth and Home Technologies L-CORNER-TRC - page 3
3 TABLE OF CONTENTS Safety and Warning Information ............................................... 2 Service Parts Lists .................................................................... 4 Section 1: Approvals and Codes ............................................ 12 Approval Listings and Codes ................................................... ...
-
Hearth and Home Technologies L-CORNER-TRC - page 4
4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 2 3 Standing Pilot 3 5 6 4 7 1 8 Log Assembly (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts P ier -TRC Beginning M anufacturing Date: 6-97 Ending M anufacturing Date: ______ 13 14 9 15 16 9 10 12 11 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 5
5 (NG , LP) Exploded Parts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPOR TAN T : L'information fournie dans cette brochure n'est valide que pendant une c ...
-
Hearth and Home Technologies L-CORNER-TRC - page 6
6 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 12 Log Assembly 1 STANDING PILOT 2 4 5 6 3 2 (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts ST -TRC Beginning M anufacturing Date: 6-97 Ending M anufacturing Date: ______ 7 8 9 10 11 7 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 7
7 (NG , LP) Exploded Parts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPOR TAN T : L'information fournie dans cette brochure n'est valide que pendant une c ...
-
Hearth and Home Technologies L-CORNER-TRC - page 8
8 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 9 Log Assembly STANDING PILOT 1 2 5 6 4 3 7 8 15 (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts L-C orner -TRC Beginning M anufacturing Date: 6-97 Ending M anufacturing Date: ______ 10 13 15 14 11 12 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 9
9 (NG , LP) Exploded Par ts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPOR TAN T : L'information fournie dans cette brochure n'est valide que pendant une ...
-
Hearth and Home Technologies L-CORNER-TRC - page 10
10 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. STANDING PILOT 1 3 7 8 4 6 5 2 9 Log Assembly (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts R-C orner -TRC Beginning M anufacturing Date: 6-97 Ending M anufacturing Date: ______ 10 11 13 12 16 15 14 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 11
11 (NG , LP) Exploded Par ts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPOR TAN T : L'information fournie dans cette brochure n'est valide que pendant une ...
-
Hearth and Home Technologies L-CORNER-TRC - page 12
12 Appliance Certification The Heat-N-Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: PIER-TRC, S T-TRC, L-CORNER-TRC, R-CORNER-TRC LABOR ATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace STANDARD: ANSI Z21.50•CGA2.2 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 13
13 Getting Started Introducing the Heat-N-Glo Gas Fireplaces Heat-N-Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in this Installers Guide , unless noted otherwise, applies to all models and gas control s ...
-
Hearth and Home Technologies L-CORNER-TRC - page 14
14 Figure 1. Diagram of the PIER-TRC ELECTRICAL ACCESS GAS LINE ACCESS REAR COLLARS GAS CONTROLS & LABELS BOTTOM GRILLE SIDE GLASS DOOR END GLASS DOOR TOP STANDOFFS TOP GRILLE TOP VENT COLLARS FRONT RIGHT SIDE LEFT SIDE 13 (331mm) 24 1/4 (616mm) 12 1/8 (308mm) VENT COLLARS 42 3/4 (1086mm) 28 7/8 (735mm) ELECTRICAL ACCESS 2 1/2 (64mm) 4 (102mm) ...
-
Hearth and Home Technologies L-CORNER-TRC - page 15
15 Figure 2. Diagram of the ST-TRC LEFT SIDE FRONT RIGHT SIDE TOP VENT COLLARS REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS BOTTOM GRILLE TOP GRILLE TOP S TANDOFFS GLASS DOOR 45 (1143mm) 13 (330mm) 12 1/8 (308mm) VENT COLLARS 24 1/4 (616mm) 28 7/8 (733mm) 2 1/2 (64mm) GAS LINE ACCESS 4 (102mm) 4 (102mm) 2 1/2 (64mm) ...
-
Hearth and Home Technologies L-CORNER-TRC - page 16
16 Figure 3. Diagram of the L & R CORNER-TRC LEFT SIDE FRONT RIGHT SIDE REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS BOTTOM GRILLE SIDE GLASS DOOR TOP GRILLE END GLASS DOOR TOP STANDOFFS TOP VENT COLLARS 42 3/4 (1086mm) 13 (330mm) VENT COLLARS 12 1/8 (308mm) 25 1/4 (642mm) GAS LINE ACCESS ELECTRICAL ACCESS 2 1/2 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 17
17 Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fireplace within a room. Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Sides or Ends .......... 36 ..................... 914 Floor .................................... 0 .............. ...
-
Hearth and Home Technologies L-CORNER-TRC - page 18
18 Framing should be constructed of 2 X 4 lumber or heavie r. Model A B C D E VENTED VENTED TOP REAR PIER-TRC 43 1/4 40 1/4 41 1/2 23 1/4 45 29 7/8 ST-TRC 47 46 41 1/2 23 1/4 45 29 7/8 CORNER-TRC’S 43 1/4 40 1/4 41 1/2 24 3/4 45 29 7/8 Figure 5. Framing Dimensions NOTE: DIMENSIONS SHOWN IN INCHES Shows center of 12” x 12” vent framing holes f ...
-
Hearth and Home Technologies L-CORNER-TRC - page 19
19 NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOIN T. Figure 6. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pipe) D V - 3 6 D 5 3/4” (146mm) 8 3/4” (222mm) 11 3/4” (298mm) DV-12D DV-09D DV -06D D V - 4 8 D D V - 9 0 D 7 3 / 8 ” ( 1 8 7 m m ) 6 5 / 3 2 ” ( 1 5 6 m m ) 1 1 5 / 8 ” ( 2 9 5 m ...
-
Hearth and Home Technologies L-CORNER-TRC - page 20
20 Figure 7. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use D-series direct vent pipe components and terminations (see Figures 6 and 7). Ap- proved vent system components are labeled for identifica- tion. This pipe is tested and listed as an approved compo- ne ...
-
Hearth and Home Technologies L-CORNER-TRC - page 21
21 Figure 8. Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) STRAIGHT OUT HORIZON TAL VENTING H Max. Run 24" (610 mm) Figure 9. Straight Out Horizontal Venting H V CAP ...
-
Hearth and Home Technologies L-CORNER-TRC - page 22
22 VENTING WITH ONE (1) 90° ELBOW V (F T .) H (F T .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.86m) 17’ MAX. (5.1m) 17' MAX. (5.1m) V + H = 37’ MAX. ( 11.3m) Figure 1 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 23
23 VENTING WITH TWO (2) 90° ELBOWS V (F T .) H + H 1 (F T .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5' MIN. (1.5m) 15' MAX. (4.5m) 6' MIN. (1.86m) 17' MAX. (5.1m) 17' MAX. (5.1m) V + H = 37' ...
-
Hearth and Home Technologies L-CORNER-TRC - page 24
24 VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1' MIN. (305 mm) 2' MAX. (610 mm) 3' MAX. (914 mm) 2' MIN. (610 mm) 4' MAX. (1.22 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 9' MAX. (2.7 m) 4' MIN. (1.22 m) 8' MAX. (2.48 m) 12' MAX. (3.6 m) 8' MAX. (2.48 m) 17' MAX. (5. ...
-
Hearth and Home Technologies L-CORNER-TRC - page 25
25 Figure 15. Venting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1' MIN. (305 mm) 2' MAX. (610 mm) 3' MAX. (914 mm) 2' MIN. (610 mm) 4' MAX. (1.22 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 9' MAX. (2.7 m) 4' MIN. (1.22 m) 8' MAX. (2.48 m) 15' MAX. (4.5 m) 8' ...
-
Hearth and Home Technologies L-CORNER-TRC - page 26
26 VENTING WITH THREE (3) 90° ELBOWS V (F T .) H (F T .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 17' MAX. (5.1m) NOTE: H + H 1 = 17' MAX. (5.1m) V + V 1 + H + H 1 = 37' MAX. ( 11.3m) VENTING WITH THREE (3) 9 ...
-
Hearth and Home Technologies L-CORNER-TRC - page 27
27 ! W ARNING: A 3/8 INCH (9.5 MM) BEAD OF STOVE CEMENT MUST BE PLACED AROUND THE 5 INCH (127 MM) FIREPLACE ST ARTING COL- LAR BEFORE A TT ACHING THE FIRST VENT COM- PONENT . F AILURE T O SEAL THIS JOINT MA Y CAUSE THE FIREPLACE T O OPERA TE IMPROPERL Y . SEE THE DIAGRAM . STARTING COLLAR STOVE SEALANT BEAD 1 INCH (25.4mm) FIRST VENT COMPONENT ! W ...
-
Hearth and Home Technologies L-CORNER-TRC - page 28
28 For V ertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the fireplace flue outlet by wall brackets. T o install support bracket s for vertical runs: • Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws. 4. Install Firestops For Horizontal Runs - Firesto ...
-
Hearth and Home Technologies L-CORNER-TRC - page 29
29 For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes. To install firestops for vertical runs that pass through ceilings: • Position a plumb bob directly over the center of the verti- cal vent component. • Mark the ceiling to establish the centerpoint of the vent. • Drill a hole or d ...
-
Hearth and Home Technologies L-CORNER-TRC - page 30
30 ! C. Vent Termination For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: • Rotate and interlock the ends as described at the begin- ning of the Installing Vent Components section. • The termination kit should pass through the wall firestops from the exterior of the building. • Adjust ...
-
Hearth and Home Technologies L-CORNER-TRC - page 31
31 ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ V = VENT TERMINAL X = AIR SUPP LY INLET = AREA WHERE TERMINAL I ...
-
Hearth and Home Technologies L-CORNER-TRC - page 32
32 For Vertical Terminations - To locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail. • The size of the roof hole framing dimensions depend on the pitch of the roof. There M ...
-
Hearth and Home Technologies L-CORNER-TRC - page 33
33 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necessar y. • Secure the fireplace to the framing by nailing or screwing . ! ! The diagram below shows h ...
-
Hearth and Home Technologies L-CORNER-TRC - page 34
34 Figure 31. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration. Step 6. T ...
-
Hearth and Home Technologies L-CORNER-TRC - page 35
35 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. For Standing Pilot Ignition Wiring Appliance Requirements • This appliance DOES NOT require 110-120 VAC to operate. WA ...
-
Hearth and Home Technologies L-CORNER-TRC - page 36
36 For Intermittent Pilot Ignition (IPI) Wiring Appliance Requirements This appliance requires that 110-120 VAC be wired to the junction box. Maintain correct polarity when wiring the junc- tion box. Operation using Battery Power This fireplace has an optional battery operation. The sys- tem is fully functional with the use of two “D” size batt ...
-
Hearth and Home Technologies L-CORNER-TRC - page 37
37 Step 9. Finishing Figure 35 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 4 and 5 for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front. W ARNING: WHEN F ...
-
Hearth and Home Technologies L-CORNER-TRC - page 38
38 Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F . (149° C) minimum sealant. WARNING: WHEN FINISHING THE FIREP ...
-
Hearth and Home Technologies L-CORNER-TRC - page 39
39 ! ! Step 12. Lighting the Fireplace Y ou’ve reviewed all safety warnings, you’ve checked the fireplace for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components. Now you’re ready to light the fireplace. WARNING: PLEASE REFER TO THE USER’S MANUAL FOR ALL CAUTIONS, SAFETY , AND W ARNING INFORMA TIO ...
-
Hearth and Home Technologies L-CORNER-TRC - page 40
40 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines re ...
¿Tienes una pregunta acerca de Hearth and Home Technologies L-CORNER-TRC?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Hearth and Home Technologies L-CORNER-TRC, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Hearth and Home Technologies L-CORNER-TRC probablemente compartirá una forma de solucionarlo.