Manual de instrucciones Opticon LPR5627

67 de páginas 0.32 mb
Descargar

Pasar a la página of 67

Summary
  • Opticon LPR5627 - page 1

    User’s Manual LPN5627, LPR5627 (Raster) Miniature High Speed Laser Fixed Position Scanner Manual No. 25-ULPNR101-03 February, 2003 8 Olympic Drive Orangeburg, NY 10962 Tel 845.365.0090 Fax 845.365.1251 www.OpticonUSA.com ...

  • Opticon LPR5627 - page 2

    ...

  • Opticon LPR5627 - page 3

    Contents Section 1 Introduction and Getting Started 1 Product Overview 1 Quick Start-Up Procedure 1 Section 2 Technical Specifications 2 Physical Specifications 2 Symbologies Supported 2 Optical Specification 2 Pitch 3 Skew 3 Tilt (rotation) 3 Curvature 4 LPR5627 Raster Pattern 4 Electrical Specification 5 RS232 Communications Specifications 5 Conn ...

  • Opticon LPR5627 - page 4

    Organization of this Manual This manual provides the necessary instructions for installing and using the Opticon LPN5627 and LPR5627 Fixed Position Scanners. The manual is organized as follows: Section 1 Introduction and Getting Started Describes the general operation of the LPN 5627 and LPR5627 scanners. Also provides a Quick Start-Up Procedure th ...

  • Opticon LPR5627 - page 5

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 1 Section 1 Introduction and Getting Started Product Overview The LPN5627 and LPR5627 (Raster) Fixed Position Sca nners are miniature, 500 scan per second, laser bar code readers designed to be easily incorporated in to host equipment. The high scan speed and smal ...

  • Opticon LPR5627 - page 6

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 2 This Quick Start-Up procedure will get you started. However, to best understand the full capabilities of this scanner, you should read the complete manual. Section 2 Technical Specifications Physical Specifications Case Material Zinc-die cast Dimensions 1.9 x 1. ...

  • Opticon LPR5627 - page 7

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 3 Pitch Recommended operation ( α ) at + 60 degrees or less Avoid specular reflection in the dead zone (hatched). Skew β = 0 to 6° (h = 35.4 mm, α 2 = 10° , θ = 0°, R = ∞ ) Tilt (Rotation) He i g h t of b a r cod e H atc h ed N o- R ead Specu lar Z o n e ...

  • Opticon LPR5627 - page 8

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 4 Curvature LPR5627 Raster Pattern Raster sweep pattern as seen from front of scanner Subtends a 1 ° angle from top to bottom of raster (at th e centerline) as measured from the scanner. h R JAN 13: R = 30 mm (1.2" ) or JAN 8: R= 20 mm (0.8") or Where: ...

  • Opticon LPR5627 - page 9

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 5 Electrical Specifications Operating Voltage +5VDC + 10% Current Operating 150mA idle; 350 mA max. (Laser ON) Surge 2.5 A max. RS232 Communications Specifications RS232 Data Transmission Format Parameter Default Optional Settings Timing Asynchronous No. of Start ...

  • Opticon LPR5627 - page 10

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 6 Environmental Specifications Temperature Operating +32 to +113 ° F (0 ° to +45 ° C ) Storage +14 to +140 ° F (-10 ° to +60 ° C) Humidity (non- condensing) Operating 20 to 85% Storage 20 to 90% Dust/Water Designed to meet IP54 Ambient Light Fluorescent or i ...

  • Opticon LPR5627 - page 11

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 7 Section 3 Positioning the Scanner Achieving Optimum Performance Three items greatly impact performance: 1) Distance (from the scan window) to the bar code 2) Specular Reflection 3) Quality of Bar Code Labels 1) Distance to the Bar Code The operation of the scann ...

  • Opticon LPR5627 - page 12

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 8 Readable Bar Code Width LPN5627/LPR5627 (Field-of-View Specification Based Upon 40 Degree Sweep) Distance from Window Max. Width 2.0” 2.0” 4.0” 3.5” 8.0” 6.4” 12.0” 9.3” The table above shows the field-of-view at various di stances from the windo ...

  • Opticon LPR5627 - page 13

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 9 3) Quality Bar Code Labels The quality of the bar code label can affect the sca nning performance. Poor quality labels are more difficult to decode and may result in non-reads or potential misreads. The bar code label should be printed to specifications. This me ...

  • Opticon LPR5627 - page 14

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 10 The scanner will read the barcode continuously and will display the ratio of the number of successful reads to the total number of attempts. The printout on the screen will appear as follows: (Example) 700d OK 93.5% CODE-39 TEST The number in the upper left ind ...

  • Opticon LPR5627 - page 15

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 11 Application Notes Tips for Achieving High Throughput In some applications your primary objective may be to achieve the highest possible throughput rate. The following list identifies the parameters and scanne r settings that can maximize scanning and decode thr ...

  • Opticon LPR5627 - page 16

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 12 Tips for Verifying the Presence of a Bar Code If the scanner is operated in the “trigger enabled” mode and the trigger is activated, one of three conditions may occur: A bar code is scanned and decoded. Decoded data is transmitted A bar code is scanned but ...

  • Opticon LPR5627 - page 17

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 13 Section 4 Configuring the Scanner Since the operation of the LPN5627 / LPR5627 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two wa ...

  • Opticon LPR5627 - page 18

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 14 Section 5 Application Engineering Support Technical Assistance and Support Opticon is eager to help you integrate the LPN5627 / LPR5627 scanner into your application. Our technical support staff is available to answer any ques tions or work with you to adapt th ...

  • Opticon LPR5627 - page 19

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 15 Section 6 Scanner Labeling CDRH Class II Laser Device LPN5627 / LPR5627 scanners comply with Center for Devic es and Radiological Health (CDRH) regulations 21, CFR Subchapter J. It is cl assified as a Class II Laser Device The LPN5627 / LPR5627 scanners use a l ...

  • Opticon LPR5627 - page 20

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 16 Appendencies Appendix A How to Program the Scanner Appendix B Computer Programming Commands Appendix C Bar Code Programming Commands Appendix D Dimensional Drawing Appendix E Optical Performance ...

  • Opticon LPR5627 - page 21

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 17 Appendix A Programming the Scanner Two different methods can be used to prog ram parameters to configure the scanner: a. Programming via Computer Commands b. Programming via special Bar Codes from a menu page Most parameters can be programmed using either of th ...

  • Opticon LPR5627 - page 22

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 18 change only a few parameters at one time. We reco mmend that you keep a record of the changes you have made to the scanner. What if you make a mistake? Don’t worry. If you are programming the scanne r but are unsure of which parameters have been changed, scan ...

  • Opticon LPR5627 - page 23

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 19 Appendix B Computer Programming Commands All commands must be preceded by an 'ESC' character and be followed by a 'Carriage Return' character. Shaded areas indicate factory default settings. Enable Disable Global Defaults U1 Enable Factory D ...

  • Opticon LPR5627 - page 24

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 20 Enable Disable Options for Codabar (NW-7) 7K 7L Enable 1 character read F0 Do not transmit start/stop characters F1 Transmit start/stop as ABCD/TN*E F2 Transmit start/stop as abcd/tn*e F3 Transmit start/stop as ABCD/ABCD F4 Transmit start/stop as abcd/abcd F5 F ...

  • Opticon LPR5627 - page 25

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 21 Communications Parameters K1 300 baud K2 600 baud K3 1,200 baud K4 2,400 baud K5 4,800 baud K6 9,600 baud K7 19,200 baud K8 38,400 baud L0 7 Data Bits L1 8 Data Bits L2 Parity = None L3 Parity = Even L4 Parity = Odd L5 1 Stop bit L6 2 Stop bits Handshaking I0 U ...

  • Opticon LPR5627 - page 26

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 22 T3 Volume = Minimum V5 Ring buzzer once at 3kHz for 200 mS V6 Ring buzzer at 3kHz & 2kHz for 200 mS V7 Ring buzzer at 2kHz & 3kHz for 200 mS W0 Disable Buzzer W1 Enable buzzer at 3kHz W2 Enable buzzer at 3kHz with 2.5kHz interval W3 Enable buzzer at 2kH ...

  • Opticon LPR5627 - page 27

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 23 X7 Xmit data from Low and High gain Good Read LED Operation T4 Disable good read LED (GRL) T8 GRL ON for 0.10 seconds after decode T5 GRL ON for 0.20 seconds after decode T6 GRL ON for 0.40 seconds after decode T7 GRL ON for 0.80 seconds after decode V0 LED ON ...

  • Opticon LPR5627 - page 28

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 24 Appendix C: Bar Code Programming Menus & Commands Index 1. Global Default & Sc anner Config uratio ns....................................... 25 2. Symbology Selectio n ................................................................... 28 3. Add/Activat ...

  • Opticon LPR5627 - page 29

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 25 1. Global Default & Scanner Configurations Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- U1 Return all parameters to Default settings -V2- % 1Y Clear all prefixes -2Z- 1Z Clear all suffixes -2[- P6 Disable Grap ...

  • Opticon LPR5627 - page 30

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 26 1. Global Default & Scanner Configurations (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- Z1 Reset all values set by command -[2- Z2 Save all values set by command (not lost upon power off) -[3- Z3 D ...

  • Opticon LPR5627 - page 31

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 27 ♦ Good LED after decoding (green, 200 ms). ♦ RS232C (9600 baud, 8, 1, no parity, no handshaking). Read Rate Mode (U8) - This mode resets all unit parameters to a predefined set of defaults for the purpose of checking the scanner read rate. When ac tivated, ...

  • Opticon LPR5627 - page 32

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 28 2. Symbology Selection Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- A0 Enable all bar code symbologies -B1- A1 Only WPC (including Addon) -B2- A2 Only Code 39 -B3- A3 Only Codabar (NW-7) -B!- A4 Only 2 of 5 (Indus ...

  • Opticon LPR5627 - page 33

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 29 2. Symbology Selection (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- J6 Only EAN +5 -K7- J7 Only Industrial 2 of 5 -K8- J8 Only Interleaved 2 of 5 -K9- Z9 Remote Menu -[:- 3. Add/Activate Specific Bar C ...

  • Opticon LPR5627 - page 34

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 30 3. Add/Activate Specific Bar Code Symbologies (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- B7 Enable MSI/Plessey -C8- B8 Enable IATA -C9- R1 Enable UPC (A/E) -S2- R2 Enable UPC (A/E) +2 -S3- R3 Enable ...

  • Opticon LPR5627 - page 35

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 31 4. Delete/Deactivate Specific Bar Code Symbologies Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 4A Disable all WPC (including Addon) -5B- 4B Disable UPC (A/E) -5C- 4C Disable UPC (A/E) +2 -5D- 4D Disable UPC (A/E) ...

  • Opticon LPR5627 - page 36

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 32 4. Delete/Deactivate Specific Bar Code Symbologies (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 4N Disable Code 128 -5O- 4O Disable MSI/Plessey -5P- 4P Disable IATA -5Q- 4Z Disable all symbologies -5[- ...

  • Opticon LPR5627 - page 37

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 33 6. Options for Code 39 Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 7C Enable 1 character (3 characters including start/stop characters) -8D- 7D Disable 1 character -8E- % C0 Disable check digit calculation -D1- % ...

  • Opticon LPR5627 - page 38

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 34 7. Options for Codabar (NW-7) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 7K Enable 1 character (3 characters including start/stop characters) -8L- 7L Disable 1 character -8M- % F0 Do not transmit start/stop char ...

  • Opticon LPR5627 - page 39

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 35 Codabar (NW-7) Format Start Character 1 to 42 data digits Check digit Stop Character A . . . . . . . . T a . . . . . . . . t A . . . . . . . . A a . . . . . . . . a • Codabar (NW-7) has four different start/stop character schemes as shown above. The check dig ...

  • Opticon LPR5627 - page 40

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 36 9. Options for IATA Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- D2 Do not calculate check digit -E3- % D3 Calculate check digit (CPN + Form + Serial) -E!- D4 Calculate check digit (Form + Serial) -E5- D5 Calculat ...

  • Opticon LPR5627 - page 41

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 37 10. Fixing the Number of Digits Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 7V Enable fixation (1 Length) 7W Enable fixation (2 Lengths) (H0) Disable fixation -I1- % (H1) Enable fixation (1 length) -I2- (H4) Enab ...

  • Opticon LPR5627 - page 42

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 38 11. Creating a Prefix and/or Suffix Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 1Y Clear all Prefixes -2Z- % Z4 Display Prefix/Suffix value and length (expressed in hexidecimal format) -[5- The scanner can be pro ...

  • Opticon LPR5627 - page 43

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 39 12. Setting Prefixes (Identifying the Symbology) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 1Y Clear all Prefixes -2Z- % N1 UPC-A -O2- M0 UPC-A +2 or +5 -N1- N2 UPC-E -O3- M1 UPC-E +2 or +5 -N2- N3 EAN-13 -O!- M ...

  • Opticon LPR5627 - page 44

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 40 12. Setting Prefixes (Identifying the Symbology) (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- M8 Code 93 -N9- M9 Code 128 -N:- D8 IATA -E9- N0 MSI/Plessey -O1- Z4 Display Prefix/Suffix value and length ...

  • Opticon LPR5627 - page 45

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 41 13. Setting Suffixes (Identifying the Symbology) (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- O2 EAN–13 +2 or +5 -P3- N9 EAN-8 -O:- O3 EAN-8 +2 or +5 -P!- O4 Code 39 -P5- O5 Codabar (NW-7) -P6- O6 In ...

  • Opticon LPR5627 - page 46

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 42 14. Direct Input of Numeric Characters Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- Q0 0 -R1- Q1 1 -R2- Q2 2 -R3- Q3 3 -R!- Q4 4 -R5- Q5 5 -R6- Q6 6 -R7- Q7 7 -R8- Q8 8 -R9- Q9 9 -R:- ...

  • Opticon LPR5627 - page 47

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 43 15. Direct Input of Alpha Characters (Z7) START/END Program Menu -[8- 0N N -1O- 0A A -1B- 0O O -1P- 0B B -1C- 0P P -1Q- 0C C -1D- 0Q Q -1R- 0D D -1E- 0R R -1S- 0E E -1F- 0S S -1T- 0F F -1G- 0T T -1U- 0G G -1H- 0U U -1V- 0H H -1I- 0V V -1W- 0I I -1J- 0W W -1X- 0 ...

  • Opticon LPR5627 - page 48

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 44 16. Direct Input of Control Characters Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 1A STX -2B- 1B ETX -2C- 1C CR -2D- 1D LF -2E- 17. Enable Number of Chara cters/Digits Transmitted This feature instructs the scan ...

  • Opticon LPR5627 - page 49

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 45 17. Enable Number of Characters/Digits Transmitted (continued) (Z7) START/END Programming Menu -[8- 3G EAN-8 -!H- 3H EAN-8 +2 or +5 -!I- 3I Code 39 -!J- 3J Codabar (NW-7) -!K- 3K Industrial 2 of 5 -!L- 3L Interleaved 2 of 5 -!M- 3M Code 93 -!N- 3N Code 128 -!O- ...

  • Opticon LPR5627 - page 50

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 46 18. Disable Number of Chara cters/Digits Transmitted Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 2A UPC-A -3B- 2B UPC-A +2 or +5 -3C- 2C UPC-E -3D- 2D UPC-E +2 or +5 -3E- 2E EAN-13 -3F- 2F EAN-13 +2 or +5 -3G- 2G ...

  • Opticon LPR5627 - page 51

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 47 18. Disable Number of Characters/Digits Transmitted (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 2N Code 128 -3O- 2O MSI/Plessey -3P- 2P IATA -3Q- 2Z Do not transmit data length (all symbologies) -3[- ...

  • Opticon LPR5627 - page 52

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 48 19. Communication Parameters (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- K7 19,200 Baud * -L8- K8 38,400 Baud * -L9- L0 7 Data Bits * -M1- L1 8 Data bits * -M2- % L2 Parity = None -M3- % L3 Parity = E ...

  • Opticon LPR5627 - page 53

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 49 20. Handshaking Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- I0 Wait for CTS from terminal = Unlimited -J1- I1 Wait for CTS from terminal = 100 mS -J2- I2 Wait for CTS from terminal = 200 mS -J3- I3 Wait for CTS f ...

  • Opticon LPR5627 - page 54

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 50 21. Buzzer Operation Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- T0 Volume = Maximum -U1- % T1 Volume = Upper Mid-range -U2- T2 Volume = Lower Mid-range -U3- T3 Volume = Minimum -U!- V5 Ring buzzer once at 3kHz f ...

  • Opticon LPR5627 - page 55

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 51 21. Buzzer Operation (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- W5 Buzzer duration 0.20 sec -X6- % W6 Buzzer duration 0.40 sec -X7- W7 Buzzer duration 0.05 sec -X8- W8 Buzzer duration 0.01 sec -X9- ...

  • Opticon LPR5627 - page 56

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 52 22. Positive & Negative Bar Codes Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- V4 Positive bar code only (black bars/white spaces) -W3- V2 Both positive & negative bar code -W5- % 23. Setting the Trigger F ...

  • Opticon LPR5627 - page 57

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 53 24. Selecting the Read Mode Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- S0 Single Read Mode (Trigger enabled mode only) -T1- S1 Multiple Read Mode -T2- % S2 Continuous Read Mode -T3- 7H Does not allow first bar d ...

  • Opticon LPR5627 - page 58

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 54 24. Selecting the Read Mode (continued) The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading. In “Continuous Read,” the scanner’s b ...

  • Opticon LPR5627 - page 59

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 55 25. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after the trigger pulse is received. The Time-out pe riod is the same whether the scanner is operating in Single ...

  • Opticon LPR5627 - page 60

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 56 26. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit d ...

  • Opticon LPR5627 - page 61

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 57 27. Transmitting Error Indications (Trigger Enabled only) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 5E Do not transmit error code -6F- % 5F Transmit “BR” <CR> for bad read or no read -6G- 5G Transmit ...

  • Opticon LPR5627 - page 62

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 58 29. Good Read LED Operation Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- T4 Good read LED disabled after decode -U5- T8 Good read LED ON after decode for .10 seconds -U9- T5 Good read LED ON after decode for .20 s ...

  • Opticon LPR5627 - page 63

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 59 30. Sequencer Controls Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 8A Trigger Input (sync signal positive logic) High active -9B- 8B Trigger Input (sync signal negative logic) Low Active -9C- % 8C Sequencer outpu ...

  • Opticon LPR5627 - page 64

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 60 30. Sequencer Controls Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 8M Sequencer output one-shot duration 70 mS -9N- 8N Sequencer output one-shot duration 80 mS -9O- 8O Sequencer output one-shot duration 90 mS -9P ...

  • Opticon LPR5627 - page 65

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 61 Appendix D Dimensional Drawings All dimensions in millimeters ...

  • Opticon LPR5627 - page 66

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 62 Appendix E LPN5627 - Optical Performance (typical unit) Depth of Fiel d, PCS = .9 0123456789 1 0 1 1 1 2 20.0 mil 15.0 mil 13.3 mil 10.0 mil 6.0 mil Resolution Distance from Unit (inches) LPR5627 (Raster) - Optical Performance (typical unit) Depth of Field, PCS ...

  • Opticon LPR5627 - page 67

    Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 63 Notes ...

Fabricante Opticon Categoría Scanner

Los documentos del dispositivo Opticon LPR5627 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Opticon
- manuales de instrucciones LPR5627
- hojas de producto Opticon
- folletos informativos
- o etiquetas energéticas Opticon LPR5627
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Opticon LPR5627.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Opticon LPR5627, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Opticon LPR5627. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Opticon LPR5627.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Opticon LPR5627, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Opticon LPR5627. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Opticon LPR5627.

El manual de instrucciones completo de Opticon debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Opticon LPR5627 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Opticon LPR5627, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Opticon LPR5627 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Opticon LPR5627 - que deben facilitarnos los primeros pasos durante el uso de Opticon LPR5627
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Opticon LPR5627
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Opticon LPR5627 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Opticon LPR5627?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Opticon LPR5627, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Opticon LPR5627 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)