    - 1 - 10001293 11/01 Rev. 1 Rear V ented Direct V ent Models DVRS3 DVRSL DVRSR DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS: * Do not try to light any appliance. * Do not touch any electric switch * Do not use any phone in your buildin ...

  • Vermont Casting DVRSL - page 2

    - 2 - T ABLE OF CONTENTS Please read the Installation & Operating Instructions before using this appliance. Thank you and congratulations on your purchase of a Majestic fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and wi ...

  • Vermont Casting DVRSL - page 3

    - 3 - IMPORTANT: PLEASE REVIEW THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your Majestic gas fireplace to give off some odour the firs ...

  • Vermont Casting DVRSL - page 4

    - 4 - FIREPLACE DIMENSIONS MANTELS Depending on the width of the mantel it may be installed higher or lower from the top of the louvre opening. See drawing and chart below for proper installation height of your combustible mantel piece. Non-combustible mantels may be installed at any height above the appliance opening. When using paint or lacquer t ...

  • Vermont Casting DVRSL - page 5

    - 5 - Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control which has been under water. Fig. 4 Fig. 3 Rear ........ 0 mm/0 inches Floor ........ 0 mm/0 inches Top .......... 0 mm/0 inches Front & Side Glass 36" (914mm) t ...

  • Vermont Casting DVRSL - page 6

    - 6 - 1/2" GAS SUPPLY 1/2" X 3/8" REDUCER 3/8" NIPPLE 3/8" NIPPLE 3/8" NIPPLE 3/8" X 3/8" SHUT OFF VALVE 3/8" UNION When using copper or flex connector use only approved fittings. When using black iron pipe always provide a union so that gas line can be easily disconnected for burner or fan servicing. Se ...

  • Vermont Casting DVRSL - page 7

    - 7 - V V V V V V V V V X X X D E B B B C B M B A J K A F L G G TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) H I Fixed Closed Fixed Closed Openable Openable Fixed Closed G G N N GENERAL VENTING Your fireplace is approved to be vented either through the side wall, or vertical through the roof. - Only Majestic v ...

  • Vermont Casting DVRSL - page 8

    - 8 - Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A = Combustible 6"(152mm) Noncombustible 2"(50mm) B = Combustible 6"(152mm) Noncombustible 2"(50mm) A Balcony - with no side wall G = Combustible 24"(610mm) Non-Combustible 18"(4 ...

  • Vermont Casting DVRSL - page 9

    - 9 - *IMPORTANT* Minimum clearance between vent pipes and combustible materials is one (1") inch (25 mm) on bottom, sides and top. Join pipes and secure joints with three (3) sheetmetal screws. (See Fig. 9) Wipe off excess sealant. GENERAL INFORMA TION ON ASSEMBLING THE VENT PIPES WITH CRIMPED ENDS BEAD LOCATION 1" FROM CRIMPED END OF PI ...

  • Vermont Casting DVRSL - page 10

    - 10 - The maximum horizontal vent run is 20 feet (6100mm) when the vertical vent rise is 7.5 feet (2286mm). Fig. 14 Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The graph showin ...

  • Vermont Casting DVRSL - page 11

    - 11 - Fig. 17 For each 45 degree elbow installed in the horizontal run (while maintaining a constant horizontal plane), the length of the horizontal run MUST be reduced by 18" (457mm). This does not apply if the 45 degree elbows are installed on the vertical part of the vent system. If a 90 degree elbow is used in the horizontal vent run (lev ...

  • Vermont Casting DVRSL - page 12

    - 12 - Fig. 19 COMBUSTIBLE WALLS (Fig. 19): Cut a 9-3/8"H x 9-3/8"W (240 mm x 240 mm) hole through the exterior wall and frame as shown NON-COMBUSTIBLE WALLS (Fig. 19): Hole opening must be 7.5" (190 mm) in diameter. (240mm) 9- 3/8 " 9- 3/8 " (240mm) 7- 1/2 " (190mm) Vent Opening — Combustible Wall Vent Opening — N ...

  • Vermont Casting DVRSL - page 13

    - 13 - Fig. 21 Fig. 20 STEP 4 (Fig. 22) Measure the horizontal length requirement including a 2" (50mm)overlap, i.e. from the elbow to the outside wall finish plus 2" (or the distance required if installing a second 90º elbow). STEP 3 (Fig. 21) Apply a bead of high temperature sealant to the inner and outer flue collars of the fireplace ...

  • Vermont Casting DVRSL - page 14

    - 14 - STEP 7 Support the horizontal pipes every 36 inches (914mm) with metal pipe straps. Make sure that the horizontal vent pipe is installed on a level horizontal plane. STEP 8 Recheck the fireplace to make sure that it is levelled, properly positioned, and nailed or screwed to the floor. If applied, the fireplaces adjustable frame drywall strip ...

  • Vermont Casting DVRSL - page 15

    - 15 - FOUNDATION RECESS SNORKEL SCREWS WALL SCREWS SHEET METAL WATERTIGHT SEAL AROUND PIPE If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first and then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes ou ...

  • Vermont Casting DVRSL - page 16

    - 16 - Fig. 34 1. Locate your fireplace. 2. Plumb to centre of the (4") 90º transition elbow (7DVRT90) from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1 inch clearance to ...

  • Vermont Casting DVRSL - page 17

    - 17 - DVR SERIES CRIMPED VENTING COMPONENTS 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7DVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 12/12 roof pitch for 7DVSKV-F order flat roof Starter Kit - Model 7DVSKS -Snorkel Kit for Below G ...

  • Vermont Casting DVRSL - page 18

    - 18 - GENERAL INFORMA TION ON ASSEMBLING THE TWIST LOCK VENT PIPES When using CFM Majestic twist lock pipe it is not neces- sary to use silicone to seal the twist lock joints. The only areas that need silicone are the collars on the fireplace, the telescoping pipe (if used) and the horizontal termina- tion connection (when necessary). To join the ...

  • Vermont Casting DVRSL - page 19

    - 19 - Fig. 37 Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mm x 240mm) hole through the exterior wall and frame as shown. Fig. 37. Non-Combustible Walls: Hole opening must be 7.5" (190mm) in diameter. To locate hole centre consult with appropriate fireplace specifications, page 4. (240mm) 9- 3/8 " 10- 3/8 " (254mm) 7- 1 ...

  • Vermont Casting DVRSL - page 20

    - 20 - The maximum horizontal vent run is 20 feet (6100mm) when the vertical vent rise is 7.5 feet (2286mm). Fig. 41 Fig. 41 VERTICAL SIDEWALL INSTALLATIONS Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must ...

  • Vermont Casting DVRSL - page 21

    - 21 - INSERT Fig. 44 The maximum number of elbow degrees in a system is 270 o . (This does not include transition elbow from rear vent to vertical vent.) Fig. 44 Sample: 1 - 90 o 2 - 45 o 3 - 45 o 4 - 90 o Total - 270 o 90" 2286mm 120" 3048mm 84" 2134mm 90 o elbow=3' Fig. 43 SEE PAGE 23 FOR VENTING REQUIREMENTS FOR SNORKELS. 3 ...

  • Vermont Casting DVRSL - page 22

    - 22 - VENT SIDEWALL INSTALLATION *IMPORTANT* Minimum clearance between vent pipes and combustible materials is one (1") inch (25 mm) on bottom, sides and top. Vent Starter Kit 7TDVSK, plus Transition Elbow 7TDVRT90 must be used in Vertical Sidewall installations. The 4" pipe must be centred inside the 7" pipe coming off the 7TDVRT90 ...

  • Vermont Casting DVRSL - page 23

    - 23 - X Sealing vent pipe and firestop gaps with high temperature sealant will restrict cold air being drawn in around fireplace. Fig. 52 STEP 5 (Fig. 52) Use the appropriate length of pipe section – telescopic or fixed – and install. The 20" section of pipe which goes through the wall is packaged with the 7TDVSK kit, and can be cut to su ...

  • Vermont Casting DVRSL - page 24

    - 24 - DO NOT BACK FILL AROUND SNORKEL. SOIL SHOULD NOT BE LESS THAN 4" BELOW SNORKEL. FOUNDATION RECESS SNORKEL SCREWS WALL SCREWS SHEET METAL WATERTIGHT SEAL AROUND PIPE If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first and then secure to snorkel with se ...

  • Vermont Casting DVRSL - page 25

    - 25 - 1. Locate your fireplace. 2. Plumb to centre of the (4") 90 o transition elbow (7TDVRT90) from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1 inch clearance to the ven ...

  • Vermont Casting DVRSL - page 26

    - 26 - 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit - Model 7TDVSKS -Snorkel Kit for Below Grade Installation 45 o elbow kit ...

  • Vermont Casting DVRSL - page 27

    - 27 - SIDE GLASS REMOVAL 1. Shut off gas. 2. Let the fireplace cool if it has been operating. 3. Remove side top louvre. (See Louvre Removal) 4. Open the side lower louvre assembly. 5. Release the two clamps at the bottom of the window frame by pulling down on the clamp handles. 6. Lift off the glass frame as shown. 7. To reinstall glass follow th ...

  • Vermont Casting DVRSL - page 28

    - 28 - REAR REFRACTORY BOTTOM SIDE REFRACTORY BOTTOM SIDE REFRACTORY BOTTOM END REFRACTORY BOTTOM REFRACTORY MANIFOLD SIDE CERAMIC REFRACTORY INSTALLATION 1 . Unpack ceramic refractory from its carton. HANDLE REFRACTORY CAREFULLY. 2. Place bottom refractory manifold side onto fireplace floor and slide under rear refractory. 3. Place bottom sides on ...

  • Vermont Casting DVRSL - page 29

    - 29 - INSTALLATION OF LOGS Left and right side are defined using the manifold as reference. Facing the manifold,the left side is on your left and the right side is on your right. Fig. 69 Fig. 70 Top logs must be placed properly onto notches LAVA ROCK The lava rock provided with this fireplace must be placed on the firebox base on either side of th ...

  • Vermont Casting DVRSL - page 30

    - 30 - 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may resu ...

  • Vermont Casting DVRSL - page 31

    - 31 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT 820 NOV A MILLIVOL T V AL VE START CHECK GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK GAS SUPPLY ON • SHUTOFF VALVE OPEN • CONFIRM GAS HOOK-UP LIGHT PILOT WITH PIEZO IGNITION • ELECTRODE GAP MIN. 1/8" • ELECTRODE CRACKED • ELECTRODE CABLE ATTACHED • PIEZO IGNITOR GENERATES SPARK ? ...

  • Vermont Casting DVRSL - page 32

    - 32 - The burner and control system consists of: • main burners • gas orifices • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician. 1. Turn off pilot light ...

  • Vermont Casting DVRSL - page 33

    - 33 - REPLACEMENT P AR TS - DVRS3 & DVRSL / DVRSR FOR FIREPLACES EQUIPPED WITH SIT 820 MILLIVOLT GAS VALVE ...

  • Vermont Casting DVRSL - page 34

    - 34 - REPLACEMENT P ARTS LIST - DVRS3/DVRSL/DVRSR D ESCRIPTION P AR T N O . DVRS3 DVRSL/DVRSR 1. Log Set Complete 10001271 100001271 1a. Log - Ember Log Set B18 B18 1b. Log - Ember Log Set B19 B19 1c. Log - Rear Pilot Side B20 B20 1d. Log - Rear Front Side B21 B21 1e. Log - Side Front B22 B22 1f. Log - Side Rear B23 B23 1g. Log - Center Right B24 ...

  • Vermont Casting DVRSL - page 35

    - 35 - EB1 1. Slide fan assembly from the left side into fireplace opening, line up mounting holes with screw studs on rear of fireplace and fasten with #10-24 hex nuts. 2. Install thermal sensor on bottom of firebox using #10-24 hex nuts. 3. (Option A) - Place electronic fan speed control box on bottom of fireplace base, lining up mounting holes w ...

Fabricante Vermont Casting Categoría Ventilation Hood

Los documentos del dispositivo Vermont Casting DVRSL que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Vermont Casting
- manuales de instrucciones DVRSL
- hojas de producto Vermont Casting
- folletos informativos
- o etiquetas energéticas Vermont Casting DVRSL
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Vermont Casting DVRSL.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Vermont Casting DVRSL, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Vermont Casting DVRSL. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Vermont Casting DVRSL.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Vermont Casting DVRSL, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Vermont Casting DVRSL. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Vermont Casting DVRSL.

El manual de instrucciones completo de Vermont Casting debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Vermont Casting DVRSL - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Vermont Casting DVRSL, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Vermont Casting DVRSL que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Vermont Casting DVRSL - que deben facilitarnos los primeros pasos durante el uso de Vermont Casting DVRSL
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Vermont Casting DVRSL
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Vermont Casting DVRSL en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Vermont Casting DVRSL?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Vermont Casting DVRSL, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Vermont Casting DVRSL probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)