Manual de instrucciones Procom MD100TBA

38 de páginas 1.65 mb
Descargar

Pasar a la página of 38

Summary
  • Procom MD100TBA - page 1

    1 CAUT ION - FO R YO UR S AFET Y V ent-Free Gas W all Heater Blue Flame W ARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane gases. PC-MD100TBE-0902 Model # MD100TBA MD200TBA MD300TBA MD100HBA MD200HBA MD300HBA MD200TBA-BB MD300TBA-BB MD200HBA-BB MD300HBA-BB W AR ...

  • Procom MD100TBA - page 2

    2 2 T ABLE OF C ONTEN TS Important Safety Information ..............................................................................................................................5 Product Features................................................................................................................................................7 Prepar ...

  • Procom MD100TBA - page 3

    3 PROD UCT SPEC IFIC A TIONS MODEL MD100 TBA MD200 TBA MD300 TBA BTU (available) 10,000 20,000 30,000 Gas T ype Using Natural Gas Using Natural Gas Using Natural Gas Pressure Regulator Setting 4 in. W .C. 4 in. W .C. 4 in. W .C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum 10.5 in. 10.5 in. 10.5 in. Minimum * 5 ...

  • Procom MD100TBA - page 4

    4 MODEL MD200 TBA- BB MD300 TBA- BB BTU (available) 20,000 30,000 Gas T ype Using Natural Gas Using Natural Gas Pressure Regulator Setting 4 in. W .C. 4 in. W .C. Inlet Gas Pressure* (inches of water) * For purposes of input adjustment. Maximum 10.5 in. 10.5 in. Minimum * 5 in. 5 in. Gas T ype Using Propane Gas Using Propane Gas Pressure Regulator ...

  • Procom MD100TBA - page 5

    5 5 5 IMPOR T ANT SAFET Y INFOR MA TION IMPORT ANT : Read this owner ’s manual carefully and completely before trying to assemble, operate, or service this heater . Improper use of this heater can cause serious injury or death from burns, re, explosion, electrical shock, and carbon monoxide poisoning. Only a qualied installer , service agen ...

  • Procom MD100TBA - page 6

    6 6 6. If heater shuts off, do not relight until you have provided fresh, outside air . If heater keeps shutting off, have it serviced. 7. Do not run heater: Where ammable liquids or vapors are used or stored. Under dusty conditions. 8. Before using furniture polish, wax, carpet cleaner , or similar products, turn heater off. If heated, the vapo ...

  • Procom MD100TBA - page 7

    7 PRODU CT F EA TURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided). 2 GAS OPTIONS CAP ABLE Y o ...

  • Procom MD100TBA - page 8

    8 8 PREP ARING FOR INST ALLA TION Before beginning assembly or operation of the product, make sure all parts are present. Compare parts with package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts. Before installing heater ...

  • Procom MD100TBA - page 9

    9 9 AIR F OR C OMBUS TION AND VE NTILA TION W ARNING: This heater shall not be installed in a conned space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air . Read the following instructions to ensure proper fresh air for this and other fuel-burning appliances in your home. Providing Adequ ...

  • Procom MD100TBA - page 10

    10 10 DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION Determining if Y ou Have a Conned or Unconned Space Use this worksheet to determine if you have a conned or unconned space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determ ...

  • Procom MD100TBA - page 11

    1 1 1 1 Fig ure 3 - V ent ila tion Air f rom Outdoo rs Fig ure 2 - V enti lat ion Air fr om Insi de Bui lding NOTE: B a s e n o t i n c l u d e d . N o t f o r u s e i n bedrooms or bathrooms. W ARNING: If the area in which the heater may be operated is smaller than that dened as an unconned space or if the building is of unusually tight cons ...

  • Procom MD100TBA - page 12

    12 12 Figure 4 - Mouting clearances as viewed from front of heater (inches) NOTICE: This heater is i nt e nd e d f o r u se as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, y ou may run system’s circulating blower while using ...

  • Procom MD100TBA - page 13

    13 Figure 5 - Mounting Bracket Location F ASTENING HEA TER TO W ALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure 5). It has been taped there for shipping. Remove mounting bracket from back panel. Removing Front Panel of Heater 1. Remove two screws near bottom corners of lower front panel . 2. Pull bottom of l ...

  • Procom MD100TBA - page 14

    14 Attaching to W all Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry): 1. Drill holes at marked locations using 5/16-inch drill bit. For solid walls (concrete or masonry), drill at least 1 inch deep. 2. Fold wall anchor as shown in Figure 8. 3. Insert wall anchor (wings ? ...

  • Procom MD100TBA - page 15

    15 15 W ARNING: A qualied service technician must connect heater to gas supply . Follow all local codes. W ARNING: This appliance requires a 3/8-inch NPT (National Pipe Thread) inlet connection to the pressure regulator . W ARNING: Ne ve r co nne ct h ea te r t o pri va te ( no n-u ti lit y) ga s we ll s. T hi s ga s i s com mo nl y kn own a s w ...

  • Procom MD100TBA - page 16

    16 16 Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves . The installer must supply an external regulator . The external regulator will reduce incoming gas pressure. Y ou must reduce incoming gas pressure to between 1 1 and 14 inches ...

  • Procom MD100TBA - page 17

    17 17 CHECK ING GAS C ONNEC TION S Figure 17 - Equipment Shutoff V alve Figure 18 - Fuel Supply Figure 14 Figure 15 Figure 16 W ARNING: T est all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. W ARN ING: Never use an open ame to check for a leak. Apply a mixture of liquid soap and water to all join ...

  • Procom MD100TBA - page 18

    18 18 Pressure T esting Heater Gas Connections 1. Open equipment shutoff valve (see Figure 17). 2. Open gas supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Remove front panel. 5. Check all joints from equipment shutof f valve to control valve (see Figure 17). Apply mixture of liquid soap and water to gas joints. If ...

  • Procom MD100TBA - page 19

    19 19 LIGH TING INST RUCTI ONS MD100TBA & MD200TBA & MD300TBA & MD200TBA-BB & MD300TBA-BB Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap. 1. STOP! Read the safety information on the side of the heater . 2. Make sure equipment shutoff valve is fully open. 3. T urn control knob clockwise to the OFF ...

  • Procom MD100TBA - page 20

    20 20 LIGH TING INST RUCTI ONS MD100HBA & MD200HBA & MD300HBA & MD200HBA-BB & MD300HBA-BB 1. STOP! Read the safety information on the side of heater . 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise to the OFF position. 4. W ait ve (5) minutes to clear out any air . Then smell for ...

  • Procom MD100TBA - page 21

    21 21 INSPE CTIN G BUR NER Check pilot ame pattern and burner ame pattern often. PILOT FLA ME P A TTER N Figure 21 shows a correct pilot ame pattern. Figure 22 shows a incorrect pilot ame pattern. The incorrect pilot ame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off. If pilot ? ...

  • Procom MD100TBA - page 22

    22 22 CARE AND MAINTENANCE W ARNING: T urn off heater and let cool before servicing CAUTION: Y ou must keep control areas, burner , and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualied service technician. Heater may nee d mo re fr equent cleani ng due to excessi ...

  • Procom MD100TBA - page 23

    23 23 PROBLEM When ignitor button is pressed in there is no spark at ODS/pilot. When ignitor button is pressed in there is a spark at ODS/pilot but no ignition. ODS/pilot lights but ame goes out when control knob is released. POSSIBLE CAUSE 1. Ignitor electrode is positioned wrong or broken. 2. Ignitor electrode is not connected to ignitor cable ...

  • Procom MD100TBA - page 24

    24 24 PROBLEM Burner(s) does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backring during combustion. Y ellow ame during burner combustion. Slight smoke or odor during initial operation. Heater produces a whistling noise when burner is lit. Heater produces a clicking/ ticking noise just after burner is lit or shut o ...

  • Procom MD100TBA - page 25

    25 25 PROBLEM Heater produces unwanted odors. Heater shuts off in use (ODS operates). Gas odor exists even when control knob is in OFF position. Gas odor during combustion. Moisture/condensation noticed on windows. POSSIBLE CAUSE 1. Heater is burning vapors from paint, hair spray , glues, etc. See IMPORT ANT statement page 23. 2. Gas leak. See W ar ...

  • Procom MD100TBA - page 26

    26 26 26 IMPOR T ANT SAFET Y INFOR MA TION ACCESSORIES Purchase these heater accessories from your local dealer . If they can not supply these accessories, contact PRO-COM for information. EQUIPMENT SHUTOFF V AL VE For all models. Equipment shutoff valve with 1/8 in. NPT tap. (see gure 1) Optional F AN Kit The optional fan kit, part PF06-YJLF-B ...

  • Procom MD100TBA - page 27

    27 27 This list contains replaceable parts for your heater . When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIS T (MD 100T BA) P ART P ART # DESCRIPTION QTY 1 MB10053D Cabinet Assembly 1 2 MB1 1005 Reector Unite 1 3 ML087-03 Upper Glass Retainer 1 4 ML086-03 Glass 1 5 ML0 ...

  • Procom MD100TBA - page 28

    28 28 ILLUS TRA TED P ARTS MD100 TBA 2 26 ...

  • Procom MD100TBA - page 29

    29 29 This list contains replaceable parts for your heater . When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIS T (MD 200T BA & MD 300TB A) P ART MD200TBA P ART # MD300TBA P ART # DESCRIPTION QTY 1 MB10052D MB10054D Cabinet Assembly 1 2 MB1 1004 MB1 1052 Reector Unite ...

  • Procom MD100TBA - page 30

    30 30 ILLUS TRA TED P ARTS MD200 TBA & MD300 TBA 26 ...

  • Procom MD100TBA - page 31

    31 31 This list contains replaceable parts for your heater . When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIS T (MD 100HB A) P ART P ART # DESCRIPTION QTY 1 MB10056D Cabinet Assembly 1 2 MB1 1005 Reector Unite 1 3 ML087-03 Upper Glass Retainer 1 4 ML086-03 Glass 1 5 ML0 ...

  • Procom MD100TBA - page 32

    32 32 ILLUS TRA TED P ARTS MD100 HBA 26 ...

  • Procom MD100TBA - page 33

    33 33 This list contains replaceable parts for your heater . When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIS T (MD 200HB A & MD 300HB A) P ART MD200HBA P ART # MD300HBA P ART # DESCRIPTION QTY 1 MB10055D MB10057D Cabinet Assembly 1 2 MB1 1004 MB1 1052 Reector Unite ...

  • Procom MD100TBA - page 34

    34 34 ILLUS TRA TED P ARTS MD200 HBA & MD300 HBA 30 ...

  • Procom MD100TBA - page 35

    35 35 This list contains replaceable parts for your heater . When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIS T (MD 200T BA-BB & MD 300T BA-BB ) P ART MD200TBA-BB P ART # MD300TBA-BB P ART # DESCRIPTION QTY 1 MB10052D MB10054D Cabinet Assembly 1 2 MB1 1004 MB1 1052 Re? ...

  • Procom MD100TBA - page 36

    36 36 ILLUS TRA TED P ARTS MD200 TBA- BB & MD300 TBA- BB 26 27-1 27-2 28 ...

  • Procom MD100TBA - page 37

    37 37 This list contains replaceable parts for your heater . When ordering replacement parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIS T (MD 200HB A-BB & MD 300H BA-BB ) P ART MD200HBA-BB P ART # MD300HBA-BB P ART # DESCRIPTION QTY 1 MB10055D MB10057D Cabinet Assembly 1 2 MB1 1004 MB1 1052 Re? ...

  • Procom MD100TBA - page 38

    38 38 ILLUS TRA TED P ARTS MD200 HBA-B B & MD300 HBA-B B 30 31-1 31-2 32 ...

Fabricante Procom Categoría Air Conditioner

Los documentos del dispositivo Procom MD100TBA que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Procom
- manuales de instrucciones MD100TBA
- hojas de producto Procom
- folletos informativos
- o etiquetas energéticas Procom MD100TBA
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Procom MD100TBA.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Procom MD100TBA, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Procom MD100TBA. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Procom MD100TBA.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Procom MD100TBA, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Procom MD100TBA. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Procom MD100TBA.

El manual de instrucciones completo de Procom debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Procom MD100TBA - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Procom MD100TBA, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Procom MD100TBA que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Procom MD100TBA - que deben facilitarnos los primeros pasos durante el uso de Procom MD100TBA
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Procom MD100TBA
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Procom MD100TBA en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Procom MD100TBA?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Procom MD100TBA, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Procom MD100TBA probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)