    S CALE M ASTER ® P RO XE Introduction The Scale Master Pro XE Multi-Scale Digital Plan Measure has been specifically designed to simplify takeoffs from architectural and engineering drawings. • Finds linear measurements of any shape • Finds rectangular areas and volumes • Conv erts between scales and dimensions • Built-in push button count ...

  • Calculated Industries Scale Master Pro XE - page 3

    T ABLE OF C ONTENTS Getting Started Key Definitions ................................................1 Operation Keys .............................................1 Setup Keys .....................................................3 Measuring Keys .............................................5 Function Keys ............................................ ...

  • Calculated Industries Scale Master Pro XE - page 4

    Appendix Error/Auto-Range Function ....................... 30 Interference .................................................... 30 Battery/Automatic Shut-Off ...................... 31 Battery Replacement ..................................... 31 Default Settings ............................................. 32 Specifications ........................ ...

  • Calculated Industries Scale Master Pro XE - page 5

    1 – Scale Master ® Pro XE G ETTING S TARTED Key Definitions Operation Keys [ON/CLEAR] – On/Clear T urns power on. Press once to clear the display . This will not clear the last rolled measurement as it is a per manent value and can be recalled to the main display at any time by pressing [RCL] [RCL] . [SET] [ON/CLEAR] – Off Turns power off. T ...

  • Calculated Industries Scale Master Pro XE - page 6

    [RESET] – Hardware Reset If your Scale Master Pro XE should ever “lock up ,” use a paperclip or similar size object to press the RESET hole. Clears all values , including memor y . All per manent settings, including Preferences , remain intact. [SET] – Set Key Used with other keys to access second functions and place the Scale Master Pro XE ...

  • Calculated Industries Scale Master Pro XE - page 7

    [LOCK] – Lock Switch The Lock Switc h is located on the side of the unit. When the lock is activ ated, a lock symbol will be displayed in the LCD . While active y ou cannot alter Scales , Modes, Units , Preferences or the IMP/ MET (Imperial/Metric) switch. Y ou also cannot perfor m a Clear All or a Software Reset. It is advised to use the Scale M ...

  • Calculated Industries Scale Master Pro XE - page 8

    [SUB] + [SCALE] – Scrolls Back Scales Holding [SUB] and repeated presses of [SCALE] will scroll backward through the av ailable scales . [UNITS] – Unit Selection Repeated presses of [UNITS] will scroll through the av ailable units of measurement. See “Imperial Units” and “Metric Units” sections . [SUB] + [UNITS] – Scrolls Back Units H ...

  • Calculated Industries Scale Master Pro XE - page 9

    [ T ] ([RCL]) – Down Arrow Decreases the number when setting v alues for custom scales, auto-count, constant, and height. Will scroll down through the preferences . [ S ] ([M+]) – Up Arrow Increases the number when setting v alues for custom scales, auto-count, constant, and height. Will scroll up through the preferences . Measuring Keys [L] ? ...

  • Calculated Industries Scale Master Pro XE - page 10

    1) Area 2) Perimeter 3) V olume (if Height is entered) 4) W all Area (if Height is entered) 5) Stored Height (if Height is entered) 6) Stored Length 7) Stored Width [RCL] [W/LxW] – Width Recall Displays the stored width v alue. On a clear display , [W/LxW] can be pressed without [RCL] . [ON/CLEAR] + [W/LxW] – Width Clear Clears the width value. ...

  • Calculated Industries Scale Master Pro XE - page 11

    Function Keys [M+] – Memory Plus Adds the displa yed value to the accumulativ e value. [RCL] [M+] – Memory Recall Displays the value stored in accum ulativ e memory . [ON/CLEAR] + [M+] – Memory Clear Clears the accumulativ e memory value. [SET] [M+] (M-) – Memory Minus Subtracts the displa yed value from the accumulativ e memor y . [SUB] + ...

  • Calculated Industries Scale Master Pro XE - page 12

    [RCL] [SET] [COUNT] – Auto-Count Recall Displays the stored A uto-Count value . [ X PC] – PC Send When connected to a PC, sends the v alue from the main display of the Scale Master Pro XE to the PC. All values are sent in decimal for mat. [+K] – Constant Add Adds the constant v alue to the displayed measurement value . [SET] [+K] – Constant ...

  • Calculated Industries Scale Master Pro XE - page 13

    Rotate to Adjust Wheel Adjusting the Wheel The Celcon ® polymer wheel can be adjusted for each user’ s preference . T o adjust the wheel, take a small, flat-head jeweler’ s screwdriv er and slightly rotate the screw located near the wheel tip . R otating the screw about 1/4 to 1/3 turn should be sufficient. Rotating the screw within those two ...

  • Calculated Industries Scale Master Pro XE - page 14

    Preferences Preferences allow customization of how the Scale Master Pro XE functions during cer tain operations . The following preferences are av ailable: Button Beep (butn) – T og gles on or off the beep sound that occurs at the press of a button or during auto-count. Beep, On – Button beep on Beep, Off – Button beep off Rolling Click (roll ...

  • Calculated Industries Scale Master Pro XE - page 15

    (cont’ d) PC T er minate (End PC) – Deter mines where the “cursor” mov es after a value is sent to the PC. The settings represent the key being pressed on the PC keyboard: Enter – PC Enter Ta b – PC T ab Left – PC Left Arrow Right – PC Right Arrow Up – PC Up Arrow Dn – PC Do wn Arrow None – No T er minate PC Send Display (SEnd ...

  • Calculated Industries Scale Master Pro XE - page 16

    Setting Preferences: 1) Press [SET] [MODE] to access the preferences . 2) Press the [M+] ( S ) key to move up or the [RCL] ( T ) key to move down through the list of preferences . 3) When the preference to be changed is displayed, press the [W/LxW] ( X ) key to mov e forward or the [L] ( W ) key to move backward through the settings for the selecte ...

  • Calculated Industries Scale Master Pro XE - page 17

    Built-In Scales Imperial (Standard) Units Architect Engineer-I Engineer-II Map ARCH ENGI ENGII MAP 1 foot= 1 inch= 1 inch= 1 inch= 1/4” 10.0’ 300.0’ 1.0 Mi 3/8” 20.0’ 333.3’ 1.5 Mi 1/2” 30.0’ 400.0’ 2.0 Mi 3/4” 40.0’ 416.6’ 3.0 Mi 1/1 (1”) 50.0’ 500.0’ 4.0 Mi 3/2 (1 1 / 2 ”) 60.0’ 583.3’ 5.0 Mi 2/1 (2”) 83.3’ ...

  • Calculated Industries Scale Master Pro XE - page 18

    Metric Units Architect Engineer-I Engineer-II Map ARCH ENGI ENGII MAP 1:50 1:100.0 1:1,000 1:100k 1:75 1:125.0 1:1,250 1:125k 1:1 1:150.0 1:1,500 1:200k 1:2 1:200.0 1:1,625 1:250k 1:3 1:250.0 1:2,000 1:500k 1:4 1:300.0 1:2,500 1:1,000k 1:5 1:400.0 1:5,000 1:2,000k 1:10 1:500.0 1:6,000 1:2,500k 1:20 1:10k 1:25 1:12.5k 1:30 1:20k 1:40 1:25k 1:50k Use ...

  • Calculated Industries Scale Master Pro XE - page 19

    Changing Modes Repeated presses of the [MODE] key will scroll through the list of av ailable modes . Holding [SUB] when pressing [MODE] will scroll backward through the list of available modes . Changing Scales Repeated presses of the [SCALE] key will scroll through the list of av ailable scales . Holding [SUB] when pressing [SCALE] will scroll bac ...

  • Calculated Industries Scale Master Pro XE - page 20

    Operation User’s Guide – 16 ...

  • Calculated Industries Scale Master Pro XE - page 21

    Rolling a Measurement T o take a measurement with the Scale Master Pro XE : 1) T urn the unit on. If the display does not show zero (0), press the [ON/CLEAR] key to clear the display . 2) Select your type of scale by pressing the [MODE] key . Then press the [SCALE] key to select your scale . 3) Begin rolling . The display will register your measure ...

  • Calculated Industries Scale Master Pro XE - page 22

    Using the Memory Function The Memor y function allows you to add rolled or counted values . However , you cannot add dimensioned (rolled) and non- dimensioned (counted) values together . T o add rolled values: 1) Roll the first v alue.* Press [M+] . The Memory indicator “ M ” appears and the value is added to Memory . 2) R oll the next value. P ...

  • Calculated Industries Scale Master Pro XE - page 23

    Additional Memory Functions [SET] [M+] Subtracts the value in the main displa y from the value stored in Memory . [RCL] [M+] Displays the total accumulated v alue in Memory . Repeated presses of [M+] will tog gle between total accumulated v alue, number of entries in Memor y , and av erage value of all entries in Memory . [ON/CLEAR] + [M+] Clears t ...

  • Calculated Industries Scale Master Pro XE - page 24

    Programming Mode The Scale Master Pr o XE allows you to pre-set frequently used values , including: ● Custom Scales (5 Imp/5 Met) ● Auto-Count distance ● +K (Constant) value ● Height value T o begin setting values , press the [SET] key and then the desired key to be programmed. The following keys are used in programming mode: [UNITS] T og g ...

  • Calculated Industries Scale Master Pro XE - page 25

    Setting Custom Scales Y ou can store ten Custom Scales: five in Imperial Mode and fiv e in Metric Mode. Y ou can set a custom scale two wa ys: by “rolling in” a known distance or by entering the exact distance. Rolling a Custom Scale 1) Press [MODE] until # O P E N (# being a number 1-5) appears in the scale box display. 2) Press [SET] [SCALE] ...

  • Calculated Industries Scale Master Pro XE - page 26

    6) Press [M+] ( S ) to increase or [RCL] ( T ) to decrease the selected digit. Press the [W/LxW] ( X ) key to mov e to the next digit to the right or the [L] ( W ) key to mov e back to the left. 7) Once the desired v alue has been entered, press [SET] to store value and exit the programming mode. Note: Pr essing [ON/CLEAR] will exit the programming ...

  • Calculated Industries Scale Master Pro XE - page 27

    (cont’ d) 4) T o chang e the units of measurement, press [UNITS] until your desired units appear . Press the [W/LxW] ( X ) or the [L] ( W ) key to begin setting the distance . The selected digit will star t flashing. 5) In Imperial mode , the scale will be one inch equals the distance you entered. In Metric mode, entered scales are direct ratios ...

  • Calculated Industries Scale Master Pro XE - page 28

    Setting an Auto-Count The Scale Master Pr o XE has an Auto-Count function that allows you to count ho w many times you’v e rolled a certain distance. Y ou will hear a beep each time you roll that distance. T o set an Auto-Count: 1) Press [SET] [COUNT] to access the Auto-Count function. The appropriate annunciator will begin flashing “ FT IN ” ...

  • Calculated Industries Scale Master Pro XE - page 29

    (cont’ d) 4) Once the desired v alue has been entered, press [SET] to save c hanges and put the unit into Auto-Count mode . 5) R oll a distance. The unit will beep each time you roll the programmed distance. The count number in the display will increase. 6) Press [SET] [COUNT] to exit Auto-Count mode. Setting a Constant (+K) This function is used ...

  • Calculated Industries Scale Master Pro XE - page 30

    2) T o chang e the units of measurement, press [UNITS] until your desired units appear . Press the [W/LxW] ( X ) or the [L] ( W ) key to begin setting the distance . The selected digit will star t flashing. 3) Press [M+] ( S ) to increase or [RCL] ( T ) to decrease the selected digit. Press the [W/LxW] ( X ) key to move to the next digit to the rig ...

  • Calculated Industries Scale Master Pro XE - page 31

    Setting a Height The height function is used to enter a height value for finding v olume. T o set a Height: 1) Press [SET] [L] to access the height function. The appropriate annunciator will begin flashing “ FT IN ” for Imperial mode or “ M ” for Metric mode. An “ H ” will appear in the display . 2) T o chang e the units of measurement, ...

  • Calculated Industries Scale Master Pro XE - page 32

    Finding Area 1) Roll the first side and press the [L] key to store as Length. 2) Roll the second side and press [W/LxW] to store as Width. The main display will show the calculated Area. Finding Volume T o access V olume after you hav e your values set for Length, Width, and Height, press [SET] [W/LxW] . Continued presses of the [W/LxW] key will di ...

  • Calculated Industries Scale Master Pro XE - page 33

    Additional Area/Volume Functions [RCL] [L] Displays the v alue stored in the Length register . [RCL] [W/LxW] Displays the v alue stored in the Width register . [ON/CLEAR] + [L] Clears the value stored as Length. [ON/CLEAR] + [W/LxW] Clears the value stored as Width. Connecting to a PC (optional) The Scale Master Pro XE has a computer interface conn ...

  • Calculated Industries Scale Master Pro XE - page 34

    A PPENDIX Error/Auto-Range Function Error M essage – If you make an incorrect entry (such as tr ying to add dimensioned and non-dimensioned values together), the Scale Master Pro XE will display the word “ ERROR . ” Press [ON/CLEAR] to clear . Auto Range F unction – If the value is too large to display in the selected units of measurement, ...

  • Calculated Industries Scale Master Pro XE - page 35

    Battery/Automatic Shut-Off The Scale Master Pro XE is powered b y two 3-V olt CR-2032 Lithium batteries (6 volts total). T o conser ve battery power , the unit will shut itself off if it is not used for 4-6 minutes . Press the [ON/CLEAR] to restore power . All registers and settings remain intact, including all temporary registers. Battery Replacem ...

  • Calculated Industries Scale Master Pro XE - page 36

    Default Settings The following are the factory defaults of the Scale Master Pro XE : Default Default Settings Imperial Metric Mode ARCH ARCH Scale 1/4" 1:50 Custom Scales 1”:1” 1:1 Linear FT IN MM Area SQ FT SQ M V olume CU YD CU M Length 0-0 0.00 Width 0-0 0.00 Height 0-0 0.00 +K constant 0-0 0.00 Auto-Count 0-0 0.00 Count 0 0 Subtract Mo ...

  • Calculated Industries Scale Master Pro XE - page 37

    Specifications Power Source: T wo 3-V olt CR-2032 lithium batteries . Approximately 400 hours normal use. Display Method: LCD with commas, annunciators and zero suppression. Display Capacity (Main Display): 9,999,999 (7 digits) Resolution/Accuracy: .025 Inch/99.75% Note: Based on start/stop point and scale magnitude, users typically experience ± 2 ...

  • Calculated Industries Scale Master Pro XE - page 38

    Repair and Return Repair and Return Information Return Guidelines: 1. Please read the W arranty in this User's Guide to deter mine if your Calculated Industries product remains under warranty before calling or retur ning any device for evaluation or repairs . 2. If your product won't turn on, check the batteries as outlined in the User&ap ...

  • Calculated Industries Scale Master Pro XE - page 39

    Warranty Warranty Repair Service — USA Calculated Industries (“CI”) w arrants this pr odu ct against defe ct s i n ma te r ia l s an d wor k ma ns h ip for a p er io d of on e (1) yea r f rom t h e da te of or i g i na l c ons u mer p u rc ha se i n t he U. S. I f a def ec t ex i sts d ur i n g t he wa r ra nt y p er io d , CI , at it s disc ...

  • Calculated Industries Scale Master Pro XE - page 40

    Repair Service — Outside the USA T o o b t a i n w a r r a n t y o r n o n - w a r r a n t y r e p a i r s e r v i c e f o r go od s pu rc ha se d out sid e t he U. S ., co nta ct t h e de al er t hr ou gh w h ich y ou i n it i al l y pu rc ha se d t he pr odu ct . I f you c an no t re aso nab ly h ave t he p ro duc t re pa i re d i n you r ar ea ...

  • Calculated Industries Scale Master Pro XE - page 41

    FCC Class B Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to P art 15 of the FCC Rules . These limits are designed to provide reasonable protection against har mful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, ...

  • Calculated Industries Scale Master Pro XE - page 42

    User’s Guide – 38 Mail Calculated Industries, Inc. 4840 Hytech Drive Carson City, NV 89706 U.S.A. Phone (775) 885–4900 Fax (775) 885–4949 E-mail techsup@calculated.com World Wide Web www.calculated.com Contact Us ...

  • Calculated Industries Scale Master Pro XE - page 43

    Software copyrighted and licensed to Calculated Industries by Scale Master Technologies, LLC, 2009. User’s Guide copyrighted by Calculated Industries, 2009. Scale Master ® and Calculated Industries ® are registered trademarks of Calculated Industries, Inc. ALL RIGHTS RESERVED CALCULATED INDUSTRIES ® 4840 Hytech Drive Carson City, NV 89706 U.S. ...

Fabricante Calculated Industries Categoría Range finder

Los documentos del dispositivo Calculated Industries Scale Master Pro XE que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Calculated Industries
- manuales de instrucciones Scale Master Pro XE
- hojas de producto Calculated Industries
- folletos informativos
- o etiquetas energéticas Calculated Industries Scale Master Pro XE
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Calculated Industries Scale Master Pro XE.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Calculated Industries Scale Master Pro XE, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Calculated Industries Scale Master Pro XE. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Calculated Industries Scale Master Pro XE.

El manual de instrucciones del dispositivo Calculated Industries Scale Master Pro XE, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Calculated Industries Scale Master Pro XE. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Calculated Industries Scale Master Pro XE.

El manual de instrucciones completo de Calculated Industries debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Calculated Industries Scale Master Pro XE - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Calculated Industries Scale Master Pro XE, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Calculated Industries Scale Master Pro XE que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Calculated Industries Scale Master Pro XE - que deben facilitarnos los primeros pasos durante el uso de Calculated Industries Scale Master Pro XE
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Calculated Industries Scale Master Pro XE
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Calculated Industries Scale Master Pro XE en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Calculated Industries Scale Master Pro XE?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Calculated Industries Scale Master Pro XE, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Calculated Industries Scale Master Pro XE probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)