    Operation Manual LRM 1200 / LRM 1500 LRM 1500SPD LASER RANGEFINDER MONOCULAR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada ...

  • Newcon Optik LRM1200 - page 2

    ...

  • Newcon Optik LRM1200 - page 3

    IMPORTANT INFORMATION Read prior to activation You have ju st purchased a sophisticated el ectro-opti cal device that emits i nvisible laser radiation. To operate it properly, please, read this manual carefully.  NEVER direct laser beam at the eyes of pe ople or animals  NEVER aim the unit at the Sun or bright so urces of lig ht  NEVER sub ...

  • Newcon Optik LRM1200 - page 4

    1 TABLE OF CONTENTS 1. BRIEF DESCRIPTIO N ............................................ 2 1.1 Principle of operation........................................... 2 1.2 Key Feat ures ........................................................ 3 2. DEVICE APPE ARANCE ........................................ 4 3. DELIVERY S ET .............................. ...

  • Newcon Optik LRM1200 - page 5

    2 CAREFULLY READ ALL THE I NSTRUCTION S BEFORE USING THE UNIT! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANT Y AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTION LRM 1200 / 1500 / 1500SPD Laser Rangefinder Monocular (the unit) is an advanced laser rang e finder system that enables instant distanc e and spee d (1500SPD m odificat ion only) measurem ...

  • Newcon Optik LRM1200 - page 6

    3 Key Features  Distance is displayed in meters or yards  Original digital circuitry allows ranging through most types of glass, bushe s and other obst acles  Three channel optical solution (optical, laser and receiver) provides high accuracy  Two reticle shapes: -¦- or   Target quality display indicator (1200 / 1500 modification ...

  • Newcon Optik LRM1200 - page 7

    4 2 3 4 5 6 7 1 8 2. DEVICE APPEARANCE Fig. 1. Front view 1 - Eyepiece 2 - Objective lens 3 - Laser em itter lens 4 - Receiver lens 5 - M (Mo de) button 6 - A (Acti on) butt on 7 - Body of the devi ce 8 - Rubber g rip ...

  • Newcon Optik LRM1200 - page 8

    5 Fig.2. Rear view 1 - Eyepiece 9 - Battery compartment cover 10 - Tripod socket 11 - Identification imprint 12 - Classification imprint, shown below 9 11 1 12 10 ...

  • Newcon Optik LRM1200 - page 9

    6 3. DELIVERY SET Standard delivery set LRM 1200 / 1500 / 1500SPD is supplied in the following assembly: Qty LRM 1 9V Alkaline battery 1 Soft carrying c ase 1 Neck strap 1 Operation m anual 1 Warranty card 1 ...

  • Newcon Optik LRM1200 - page 10

    7 4. SPECIFICATIONS Optics Magnificati on Objective lens diameter Exit pupil diameter Field of view Type of coating 7x 25 mm 3.6 mm 8  Fully multi-coated optics Range Finder Laser Measuring range, LRM 1200 Measuring range, LRM 1500, 1500SPD Accuracy Meters/Yards display Last 10 readings recall Reticle Target quality indicator Class 1, eye safe, ...

  • Newcon Optik LRM1200 - page 11

    8 Speed Detector (LRM 1500SPD only) Measured speed range 5-400 km/ h Accuracy ±2 km/h Power Battery 9V 'Low Batte ry' indicator Yes Environmental Operational temperature range Storage temperature range -25 / +50 o C (-13 / +122 o F) -45 / +65 o C (-49 / +149 o F) Mechanics Tripod thread Weight without battery Dimensions ¼” x 20 445 g ...

  • Newcon Optik LRM1200 - page 12

    9 5. OPERATION INSTRUCTIONS 1 – Low battery indi cator 2 – Reticle (either -¦- or  ) 3 – Units of measurement 4 – Measurem ent result 5 – Target q uality indi cator 6 – Laser active i ndicator 7 – Setup m ode indicator 8 – Ready m ode indicat or 4 6 2 1 3 8 7 Fig. 3. Liquid Crystal Display as seen through the eyepiece 5 ...

  • Newcon Optik LRM1200 - page 13

    10 Changing b attery To install a battery:  Slide the battery compartm en t cover down (9, Fig. 2)  Install the battery observing polarity  Don’t appl y superfluous st rength whi le pushing t he battery inside the compartment.  Close the compartment cove r If the battery does not fit the compartment easily, it means that polarity was ...

  • Newcon Optik LRM1200 - page 14

    11 Measuring procedure To start the m easuring procedure , remove th e lens cover. L ook through the eyepi ece (1, Fig. 1, 2) a nd ad just the focus by its rotating. When the Rangefi nder is off th e LCD is blank. To activate it press and hold A butto n (6, Fig. 1) for half a second. At start the unit comes into Read y to Measure mode indicated by ...

  • Newcon Optik LRM1200 - page 15

    12 Target reflectivity depends on its c olor, surface finish, size, shape, position in relation to the laser beam, etc. Bright target colors are more reflective tha n darks. A polished surface is m ore reflective than a rough one. L arger targets reflect better t han small ones. Ra nging a ta rget perpendi cular to the laser beam provides better re ...

  • Newcon Optik LRM1200 - page 16

    13 KMH/MPH : units of spee d measurement: km/hour or miles/hour ( 3, Fig.3) (LRM 150 0SPD only). Shape of the reticle: cross shape or rectangu lar sha pe (2, Fig.3). rEC1: Data Recall mode. It returns results of the last 10 measurements on the display. Measurement results are save d in on-board me mory. When you enter the Data Recall m ode, first m ...

  • Newcon Optik LRM1200 - page 17

    14 Additional display inform ation Distance measuring procedure in cludes inst ant statistical processing of the package of si ngle measuri ng sessions. If there is more than one m easured targ et in the field of view, the embedded software estim ates the m ost probabl e one by calculating the number of reflected pulses multiplied by the target sta ...

  • Newcon Optik LRM1200 - page 18

    15 6. STORAGE AN D MAINTENANCE The unit is a s ophisticated precision optical instrum ent equippe d with laser and electronics. Ther efore, it should be handled with due care.  Keep away from direct sunlight.  Avoid impacts, jolts, dust, moisture, and sharp changes of temperature.  Do not use the device at tem peratures higher than 50 o C ...

  • Newcon Optik LRM1200 - page 19

    16 7. TROUBLESHOOTING The ranging does not work . Th e display is tra nsparent. Check the charge of the battery. Replace it if it is weak. Black dots are visible on LC D. Liquid Cryst al Display m ay have sm all black dots , scratches and other blemi shes inherited from the manufacturing pr ocess. These flaws are strictly regulated by num ber, area ...

  • Newcon Optik LRM1200 - page 20

    17 8. WARRANTY NEWCON warrants this product against defects in material and workmanshi p for one year from the date of the origi nal purchase. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product pr ove to be defective during this p eriod, pleas e deliver the product securely packaged in its ...

  • Newcon Optik LRM1200 - page 21

    18 9. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult this manual first. If the problem remains unresolved, c ontact our cust omer support department at (416) 663-6963 or toll f ree at 1-877-368-6666 . Our operating hours are 9am-5pm, M onday - Friday, Eastern Standa rd Time . At no time should equi ...

  • Newcon Optik LRM1200 - page 22

    19 10. QUALITY CERTIFICATE LRM 1200 LRM 1500 LRM 1500SPD The unit indicated above has p assed the quality inspection. Production date Serial number Quality Inspector Purchase date ...

  • Newcon Optik LRM1200 - page 23

    ...

  • Newcon Optik LRM1200 - page 24

    NEWCON OPTIK  Printed in Canada ...

Fabricante Newcon Optik Categoría Binoculars

Los documentos del dispositivo Newcon Optik LRM1200 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Newcon Optik
- manuales de instrucciones LRM1200
- hojas de producto Newcon Optik
- folletos informativos
- o etiquetas energéticas Newcon Optik LRM1200
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Newcon Optik LRM1200.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Newcon Optik LRM1200, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Newcon Optik LRM1200. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Newcon Optik LRM1200.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Newcon Optik LRM1200, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Newcon Optik LRM1200. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Newcon Optik LRM1200.

El manual de instrucciones completo de Newcon Optik debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Newcon Optik LRM1200 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Newcon Optik LRM1200, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Newcon Optik LRM1200 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Newcon Optik LRM1200 - que deben facilitarnos los primeros pasos durante el uso de Newcon Optik LRM1200
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Newcon Optik LRM1200
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Newcon Optik LRM1200 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Newcon Optik LRM1200?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Newcon Optik LRM1200, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Newcon Optik LRM1200 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)