-
CycleOps Comp 200E - page 1
PRO 300PT C OMP 200E C onsole M anual INDOOR CY CLE ...
-
CycleOps Comp 200E - page 2
2 Sy s t e m Ov e rvi e w ..................................................................................................................................................................................................p.2 I ns tallatio n .............................................................................................................. ...
-
CycleOps Comp 200E - page 3
3 T e ch n ical Sp e c s Accuracy +/-1.5% (Pro 300PT ) Sig n al T r a ns mi ss io n Digital RF I n t e rval Data Storag e U n limit e d I n t e rval Di s play 9 I n t e rv al s (i n t e r n al r e cordi n g) Op e ratio n al T e mp e ratur e 0 to 40 d e gr ees c or 32 t o 104 f Batt e ry Lif e (Hub) 1000 hour s approx. Batt e ry Lif e ( C o ns ol e ...
-
CycleOps Comp 200E - page 4
4 r e plac e m en t part n ot s uppli e d by Sari s C yc li n g Group, Sari s C ycli n g Group s hall n ot b e liabl e for a n y co s t, damag e , failur e or lo ss cau se d by th e u se of s uch u n authoriz e d se rvi c e or part s . C autio ns B e for e s tar ti n g a n y e x e rci se program, co ns ult with your ph y s icia n or h e alth prof e ...
-
CycleOps Comp 200E - page 5
5 C D F E G H ...
-
CycleOps Comp 200E - page 6
6 Console t o bra c ke t To c onne ct t he c onsole t o t he bra c ke t, slide t he c onsole down on t o t he bra c ke t . Be sure t o slide t he c onsole c omple t ely down on t o t he bra c ke t t o ensure a solid c onne ct ion be t ween t he c onsole and t he bra c ke t . Make sure t he c on t a ct poin t s be t ween t he c onsole and bra c ke t ...
-
CycleOps Comp 200E - page 7
7 Console Na vigation U P and DOWN A RR OW S [U P A RR OW ] and [DOWN A RR OW ] are used t o s c roll t hrough t he differen t fields on t he c onsole. [U P A RR OW ] and [DOWN A RR OW ] c an also be used t o move t he na viga t ion c ursor on t he [MAIN MENU]. Addi t ionally , t hese arrows are used t o in c rease or de c rease values when es t ab ...
-
CycleOps Comp 200E - page 8
8 SELECT MODE Ride Time To t al t ime t ha t t he user has ridden t he bike. Time is displa yed in (hours : minu t es : se c onds). RIDE TIME 00:00:00 MPH CAD MENU WATTS HR H SELECT MODE Energy in KJ This value is a measure of t he t o t al work done over t he c ourse of your ride. P ower is displayed in wa tt s and is a measure of t he in t ensi t ...
-
CycleOps Comp 200E - page 9
9 SELECT MODE MAX, A VG, and CURRENT Field This line displays t he c urren t, ma x imum or av erage values for t he ride or in t erval. From t he dashboard displa y , press [U P A RR OW ] or [DOWN A RR OW ] t o move t wo spa c es abov e [MENU]. P ress [ S ELECT ] t o t oggle be t ween [MAX] , [A VG] , and c urren t readings. Curren t readings are d ...
-
CycleOps Comp 200E - page 10
10 SELECT MODE Interval Mode The c onsole w orks as a lap marker , and is essen t ially always on. 1) Fr om any lo c a t ion on t he dashboard dis- play press and release [MODE] and [ S ELECT ] simul t aneously . [INT ] and t he new in t erval # will briefly appear before dis- appearing again t o t he ba c kground in t he field lo c a t ed abov e [ ...
-
CycleOps Comp 200E - page 11
11 SELECT MODE Interval Memory Mode 1) T o a cc ess s t ored in t erval informa t ion press [U P A RR OW ] or [DOWN A RR OW ] t o s c roll t o t he in t erval line ( S ee In t erval Mode) and hold [MODE] for t wo (2) se c - onds. This brings in t erval mode t o t he f ore- ground. P ress [MODE] t o move in t erval numbers up , and [ S ELECT ] t o m ...
-
CycleOps Comp 200E - page 12
12 SELECT MODE Console Setup 1 1) Fr om t he dashboard display press [U P A RR OW ] or [DOWN A RR OW ] t o move t he c ur- sor t o [MENU] and press [ S ELECT ]. CLOCK 02:06:07P MPH CAD MENU WATTS HR H Console Setup SELECT MODE Console Setup 2 2) P ress [ S ELECT ] t o en t er [ R ETU R N TO R IDE]. MAIN MENU RETURN TO RIDE SETUP USER RIDE CLEAR MEM ...
-
CycleOps Comp 200E - page 13
13 Setup User Information 1 1) Fr om [MAIN MENU] press [DOWN A RR OW ] t o s c roll t o [ S ETU P U S E R R IDE] and press [ S ELECT ]. SELECT MODE MAIN MENU RETURN TO RIDE SETUP USER RIDE CLEAR MEMORY TEST SETUP Setup User Information 2 2) P ress [DOWN A RR OW ] t o s c roll t o [U S E R ] files and press [ S ELECT ] t o c hose a user. ( S ee &quo ...
-
CycleOps Comp 200E - page 14
14 P ower Zone 5 5) P ress [DOWN A RR OW ] t o s c roll t o [ZONE 1] and press [ S ELECT ] t o en t er t he upper % t raining zone. P ress [U P A RR OW ] or [DOWN A RR OW ] t o adjus t value and press [ S ELECT ] t o reen t er t he s c rolling menu. SELECT MODE P ower Zone 4 4) P ress [ S ELECT ] t o manually inpu t a previ- ously de t ermined anae ...
-
CycleOps Comp 200E - page 15
15 P ower Zone 8 9) T o rese t defaul t zo ne se tt ings , press [DOWN A RR OW ] t o s c roll t o [ R E S ET ] and press [ S ELECT ]. 10) T o begin a power zone based ride , press [DOWN A RR OW ] t o s c roll t o [ R ETU R N] and press [ S ELECT ]. P ress [DOWN A RR OW ] t o s c roll t o [ R ETU R N] and press [ S ELECT ] on c e again. SELECT MODE ...
-
CycleOps Comp 200E - page 16
16 Hear t Rate Zone 3 3) P ress [DOWN A RR OW ] t o s c roll t o [HEA R T R A TE ZONE] and press [ S ELECT ]. Hear t Rate Zone 2 2) P ress [DOWN A RR OW ] t o s c roll t o [U S E R ] files and press [ S ELECT ] t o c hose a user. ( S ee " S e tt ing User Informa t ion" t o es t ablish a user profile). Hear t Rate Zone 4 4) P ress [ S ELEC ...
-
CycleOps Comp 200E - page 17
17 Hear t Rate Zone 6 6) P ress [DOWN A RR OW ] and [ S ELECT ] t o adjus t [ZONE 2]. Con t inue t his pro c ess t o se t [ZONE S 1-4]. NOTE: The lower % t rain- ing zone will au t oma t i c ally se t t o t he previ- ous zone's upper limi t . Hear t Rate Zone 7 7) T o rese t defaul t [ZONE] se tt ings sele ct and press [ R E S ET ]. 8) T o beg ...
-
CycleOps Comp 200E - page 18
18 Settings 3 3) P ress [DOWN A RR OW ] t o s c roll t o [ S ET- TING S ] and press [ S ELECT ]. Settings 2 2) P ress [DOWN A RR OW ] t o s c roll t o [U S E R ] files and press [ S ELECT ] t o en t er t he file. ( S ee " S e tt ing User Informa t ion" t o es t ablish a user profile). Settings 4 4) P ress [ S ELECT ] t o en t er [COM P UT ...
-
CycleOps Comp 200E - page 19
19 Settings 9 10) T o begin a ride , press [DOWN A RR OW ] t o s c roll t o [ R ETU R N] and press [ S ELECT ]. P ress [DOWN A RR OW ] t o s c roll t o [ R ETU R N] and press [ S ELECT ]. Settings 8 9) P ress [DOWN A RR OW ] and s c roll t o [A UDIBLE] and press [ S ELECT ]. Use [U P A RR OW ] or [DOWN A RR OW ] t o t oggle be t ween [ON] and [OFF] ...
-
CycleOps Comp 200E - page 20
20 Settings (A verages) These se tt ings allow for be tt er pa c ing during Time T rial effor t s by allowing for a slow er upda t e of t he display . Changing t hese se tt ings applies only t he display c onsole and does no t affe ct t he re c ording ra t e for do wnload Setting (A verages) 1 1) Fr om [MAIN MENU] press [DOWN A RR OW ] t o s c roll ...
-
CycleOps Comp 200E - page 21
21 Setting (A verages) 6 6) R epea t s t eps 3 , 4 , and 5 for [ SP EED A VG] and [CADENCE A VG]. P ress [ S ELECT ] t o a cc ep t c hanges and reen t er s c rolling menu. 7) P ress [DOWN A RR OW ] t o s c roll t o [HEA R T A VG] and press [ S ELECT ]. 8) P ress [U P A RR OW ] or [DOWN A RR OW ] t o t oggle be t ween [F A S T] , [ S LO W ] , and [ ...
-
CycleOps Comp 200E - page 22
22 SELECT MODE MAIN MENU RETURN TO RIDE SETUP USER RIDE CLEAR MEMORY TEST SETUP SELECT MODE R ETURN T O R IDE 1 USER A 2 USER B 3 USER C 4 USER D 5 USER E 6 USER F SELECT MODE CYCLE COMPUTER POWER ZONE HEART RATE ZONE USER INFORMATION SETTINGS RETURN Settings (Zeros) These se tt ings de t ermine if zero r eadings will be in c luded in average r ead ...
-
CycleOps Comp 200E - page 23
23 Setup ( Time & Date) 1 1) Fr om [MAIN MENU] press [DOWN A RR OW ] t o s c roll t o [ S ETU P ] and press [ S ELECT ]. Setup ( Time & Date) 2 2) P ress [ S ELECT ] t o en t er [ TIME AND DA TE]. SELECT MODE MAIN MENU RETURN TO RIDE SETUP USER RIDE CLEAR MEMORY TEST SETUP SELECT MODE S ETUP TIME AND DATE MODES RETURN Setup ( Time and Date) ...
-
CycleOps Comp 200E - page 24
24 Setup Modes 1 1) Fr om [MAIN MENU] press [DOWN A RR OW ] t o s c rol l t o t hrough t o [ S ETU P ] and press [ S ELECT ]. 2) P ress [ S ELECT ] t o en t er [MODE S ]. Setup Modes 2 3) P ress [ S ELECT ] t o en t er [ S LEE P TIME]. 4) P ress [U P A RR OW ] or [DOWN A RR OW ] t o t oggle be t ween 1-9 (display ed in minu t es). T his de t ermine ...
-
CycleOps Comp 200E - page 25
25 About 3) P ress [ S ELECT ] t o reen t er [ TE S T ] mode. P ress [DOWN A RR OW ] and press [ S ELECT ]. 4) P r ess [DOWN A RR OW ] t o s c roll t o [L CD TE S T ] and press [ S ELECT ]. 5) P ress [ S ELECT ] t o end t es t . 6) R epea t s t eps 4 and 5 [BACKLIGHT ] , [HUB HEA R T WHEEL] , [T O R QUE] , [DA T A R IDE] , and [DA T A TE S T] . 7) ...
-
CycleOps Comp 200E - page 26
26 FCC St a t emen t of Complian c e This devi c e c omplies wi t h par t 15 of t he FCC R ules. Opera t ion is subje ct t o t he following c ondi t ions: (1) T his devi c e may no t c ause harmful in t erferen c e , and (2) t his devi c e mus t a cc ep t any in t erferen c e re c eived , in c luding in t erferen c e t ha t may c ause undesirable o ...
¿Tienes una pregunta acerca de CycleOps Comp 200E?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con CycleOps Comp 200E, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con CycleOps Comp 200E probablemente compartirá una forma de solucionarlo.