    WARNING : Improper installation, adjustment , alterat ion, service or maint enance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applian ...

  • AquaStar NG - page 2

    2 6 720 606 446 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exc hanger in the Aquastar. This same flow opens the gas valve, and the burners are ...

  • AquaStar NG - page 3

    3 6 720 606 446 M I N I M U M I N S T ALLA TI O N C LE ARAN C E S FR OM C O M B U STI B LE AN D N ON C OM B U S TI B LE MA TE R IAL S FR O NT VI EW SIDE V IEW A Q U AST AR MO DE L 38B MODEL 38B TOP (A) 12 " FRONT (B) 4 " BACK 0 " SIDES 4 " FLOOR (C) 12 " VENT DIAMETER 4 " ...

  • AquaStar NG - page 4

    4 6 720 606 446 G E NE R AL R U LE S T O FOLL OW FOR SAF E OPE RA TION 1. Y ou should follow these instructions when you install your heater . In the United St ates: The installation must conform with local codes or , in the absence of local codes , the National Fuel Gas Code AN SI Z223. 1 / N FP A 54. In Canada: The Installation should conform wit ...

  • AquaStar NG - page 5

    5 6 720 606 446 COMBUSTION AIR REQUIREMENT The AquaStar water heater holds cold water in its copper heat exchanger and brass water valve when not in use. Because of this, any cold air that comes in through the unit’s vent pipe is capable of freezing these components. This Installation Manual specifies the minimum vertical vent pipe and the amount ...

  • AquaStar NG - page 6

    6 6 720 606 446 Appliances located in unconfined spaces: a) An unconfined space is one whose volume is greater than 50 cubic feet per 1 0 00 Btu per hour of the combined rating of all appliances installed in the space. That would be 2000 cubic feet for the AquaStar 38B alone. b) In unconfined spaces in buildings of conventional frame, masonry, or m ...

  • AquaStar NG - page 7

    7 6 720 606 446 VENTING V ent pipe connection . WARN IN G: Do not reduce t he vent pipe size. The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney . The heater must be located as close as practicable to a vertically rising c himney or vent that has a listed vent ca ...

  • AquaStar NG - page 8

    8 6 720 606 446 MASON RY CHI M NEY : Masonry chimneys shall be built and installed in accordance with N FP S 2 1 1 or local codes . A minimum 4” diameter gas vent pipe (metal double wall T ype B ), or an approved clay flue liner or a listed c himney lining system must be used when venting into a naturally drafting, internal masonr y c himney . Lo ...

  • AquaStar NG - page 9

    9 6 720 606 446 WARNING Note: The burners of an instantaneous “on demand” water heater such as the AquaStar are only on at the time that hot water is actually being used, the vent pipe is therefore cold except for the short durations when hot water is being used, it is therefore very important that the venting and air supply be adequate to prov ...

  • AquaStar NG - page 10

    10 6 720 606 446 Connecting the pressure relief valve (PRV) A listed pressure relief valve supplied with the heater must be installed at the time of installation. Should a discharge line be added to the PRV no valve is to be placed between the P RV and the heater . No reducing coupling or other restriction may be installed in the discharge line. Th ...

  • AquaStar NG - page 11

    11 6 720 606 446 LIGHTING INSTRUCTIONS (as seen on front cover of heater) 1. ST OP! Read the s afety information on the front panel of the heater . 2. The Gas valve must be turned off by sliding the gas valve button ( ) to the far left under the OFF ( ) mark. 3. W ait five ( 5) minutes to clear out any gas. If you smell gas, ST OP! Follow “B” i ...

  • AquaStar NG - page 12

    12 6 720 606 446 Fig. 6 - Water Flow Control Knob The position you select on the temperature adjustment knob will depend on the temperature of the incoming water (50°F is average in the U.S.). If you plan to supply the AquaStar 38 B, with preheated water (i.e.) solar installation, the unit could overheat. It will then shut off on safety when the o ...

  • AquaStar NG - page 13

    13 6 720 606 446 PIL O T DO ES N O T LI GHT 1 . No gas to t he Aquastar A . Gas cock on gas line may not be open. B . Gas valve button has not been moved to “PI L O T POSITION”. Slide button to right to single flame position ( ) . 2. In-line Aquastar gas regulator jammed (usually on LP gas) Replace or unlock the regulator . Note : T he regulato ...

  • AquaStar NG - page 14

    14 6 720 606 446 B UR N ERS DO N O T IG N ITE WH EN H O T WA TE R IS TU RN E D ON 1 . Pilot is not on. Light the pilot. See lighting instructions. 2 . Pilot lighting push button not turned to proper position Be sure that once the pilot flame is on, that the gas valve button ( ) is slid all the way to the right to the ON position ( ). 3 . Cold incom ...

  • AquaStar NG - page 15

    15 6 720 606 446 4 . Btu input is too low due to insufficient gas supply Make sure your main gas line is fully opened. If using LP gas, be sure that the size of the propane tank is adequate to supply the required gas pressure. 5. Cold water is mixing with the hot water between the AquaStar and the outlet Compare water temperature at outlet of the A ...

  • AquaStar NG - page 16

    16 6 720 606 446 Fig. 9 - Diagram of AquaStar 38 B 2 4 8 10 1 7 9 11 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Pilot gas tubing 5. Main gas burner 6. Inlet gas pressure test nipple 7 . Gas valve 8. Gas control slide 9. Piezo igniter 1 0. T emperature adjustment knob 1 1 . W ater valve 3 5 6 ...

  • AquaStar NG - page 17

    17 6 720 606 446 ...

  • AquaStar NG - page 18

    18 6 720 606 446 Fig. 1 0 - I NTE RI OR COM P ON ENTS D IA G R AM AND P ARTS LI ST ...

  • AquaStar NG - page 19

    19 6 720 606 446 Fig. 1 0 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 3 8B 1 Cover 8 705 4 21 021 2 Temp eratu re ad justme nt kno b 8 702 000 182 4 Dra ft diver tor 8 705 5 05 361 5 Hea t excha nge r 8 70 5 406 149 6 Overh eat s ensor (ECO) 8 70 7 206 040 7 Hot water pipe 8 700 7 03 038 8 Main b urner asse mbly 8 708 1 20 301 LPG Mai n burn er as ...

  • AquaStar NG - page 20

    20 6 720 606 446 Fig . 1 1 - Flow chart of Aquastar 3 8 B ...

  • AquaStar NG - page 21

    21 6 720 606 446 LI M ITE D W AR R ANT Y Aquast ar General Aquastar water heaters are warranted by the Manufacturer ( B OSC H) through BB T North America . BB T North America (B BTNA ) will furnish a replacement heat exc hanger and will furnish a replacement of any other part which fails in normal use and service within the applicable periods speci ...

  • AquaStar NG - page 22

    22 6 720 606 446 ...

  • AquaStar NG - page 23

    23 6 720 606 446 ...

  • AquaStar NG - page 24

    Bosch Heating System Co. Foschan Guangdong C. T . 5283 1 5 P .R . China Recycled paper 3 1 & 2 1 s e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V ES R A E Y 2 Y R E V ES R A E Y 5 - 3 Y R E V E E V L A V R E T A W E T A C I R B U L † E V L A V R E T A W D L I U B E R † N E E R C S R E T L I F R E T A W T C E P S N I † Y L B ...

Fabricante AquaStar Categoría Water Heater

Los documentos del dispositivo AquaStar NG que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos AquaStar
- manuales de instrucciones NG
- hojas de producto AquaStar
- folletos informativos
- o etiquetas energéticas AquaStar NG
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones AquaStar NG.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje AquaStar NG, instrucciones de servicio, instrucciones cortas o instrucciones de usuario AquaStar NG. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto AquaStar NG.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo AquaStar NG, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar AquaStar NG. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de AquaStar NG.

El manual de instrucciones completo de AquaStar debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual AquaStar NG - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice AquaStar NG, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de AquaStar NG que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo AquaStar NG - que deben facilitarnos los primeros pasos durante el uso de AquaStar NG
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con AquaStar NG
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de AquaStar NG en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de AquaStar NG?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con AquaStar NG, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con AquaStar NG probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)