Manual de instrucciones Osburn HYBRID-45 MF

27 de páginas 1.31 mb
Descargar

Pasar a la página of 27

Summary
  • Osburn HYBRID-45 MF - page 1

    PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufacture d by: Stove Builder International Inc. Quebec City (Quebec) CANADA 45165 • Warning: If your a ppliance is not properly installed a house fire ma y result. For your safety, follow the installatio n directions. Conta ct local buil ding or fir e officials about rest rictions and installa ti ...

  • Osburn HYBRID-45 MF - page 2

    Thank you for purchasing the HYBRID-45 MF pe llet stove. You are now prepared to burn wood in the most efficient, conv enient way possible. To achieve the safest, most efficient and most enjoyable performance from y our stove, you must do three th ings: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of th ...

  • Osburn HYBRID-45 MF - page 3

    • Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. • Keep foreign objects out of the hopper. • Never use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Keep all such liquids well away from ...

  • Osburn HYBRID-45 MF - page 4

    INTRODUCTION -------------------------------------------------------------------------------- ------------- 2 SAFETY PRECAUTIONS -------------------------------------------------------------------------------- -- 3 SPECIFICATIONS -------------------------------------------------------------------------------- ----------- 5 INSTALLATION ------------ ...

  • Osburn HYBRID-45 MF - page 5

    OSBURN HYBRID-45 MF FREESTANDING PELLET STOVE Width: 27” Height: 30 1/2” Depth: 24 5” Weight: 230 lbs. Flue size: 3” or 4” Hopper Capacity: Up to 70 lbs. (This can vary widely depending on pellet size, length, and diameter) EPA status: exempt Burn rate: 1 lb. to 5.5 lbs. per hour BTU range: 8,200 to 45,000 Electrical consumption: 3.5 Amps ...

  • Osburn HYBRID-45 MF - page 6

    COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 3” ins ide diameter metallic pipe, either flexible or rigid, may be atta ched to the inlet at the stove’s rear (refer to figures 4, 5 & 6). A rodent guard (minim um ¼” wire mesh) must be used at the terminus (refer t ...

  • Osburn HYBRID-45 MF - page 7

    Equivalent Vent Length (EVL) The longer the run of pipe in your installation, the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of Equivalent Vent Length (EVL). • Horizontal runs shall not exceed 10 feet of EVL. • To calculate EVL, use the fo llowing conv ...

  • Osburn HYBRID-45 MF - page 8

    A. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9 & 10 for basement installation) NOTE: Follow L-Vent chimney manufacturer’s instructions. OPTION: To achieve a center vertical installation, a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove. OPTION: Install L-Vent elb ...

  • Osburn HYBRID-45 MF - page 9

    C. VERTICALLY INTO EXISTING M ASONRY FIREPLACE NOTE: Follow L-Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition. 2. You will need a pipe length equal to the chimney height from the hearth. If outside combus tion air is to be used, you wil ...

  • Osburn HYBRID-45 MF - page 10

    OPTIONAL LOG SET INSTALLATION To install the optional log set, you first need to rem ove the four screws indicated on figure 14a. Keep the screws. Locate t he two fixation brackets figure 14b that cam e with your owner’s manual. Fix the two brackets using the same scr ews y ou have removed. Lay the log set inside the firebox as shown on figure 14 ...

  • Osburn HYBRID-45 MF - page 11

    PROPER FUEL THIS STOVE IS APPROVED FOR BURNING PELLETI ZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not per mitted. It will violate the building c ...

  • Osburn HYBRID-45 MF - page 12

    a. MODE SWITCH • When the mode switch is pressed, the stove will automatically ignite. If the manual mode is selected, the heat level must be selected manually to adjust the stove’s heat output to the desired level. If the thermostat mode is selected, the stove will automatica lly modulate between the lowest heat level and the heat level select ...

  • Osburn HYBRID-45 MF - page 13

    IF THE STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blo wers will run unt il the stove cools down. This will take a few minutes. After the stove’s components stop running, an error message will appear . To restart, press the “RESET” button, refill the hopper , and press the “FUEL FEED” button until pellets begin to ...

  • Osburn HYBRID-45 MF - page 14

    OPERATING THE STOVE USING A THERMOSTAT A thermostat may help you maintain a constant house temperature automatically. A milli volt thermostat or 24 Volt thermostat is required. A fixed wall mount or hand held model can be used. The control panel can be set up two ways to operate your stove in thermostatic mode. THERMOSTAT INSTALLATION • Unplug th ...

  • Osburn HYBRID-45 MF - page 15

    OPERATING SAFETY PREC AUTIONS PLEASE READ THIS! a. If y ou notice a smoldering fire (burnpot full but no visible flam e) AND a he avy smoke buildup in firebox , immediately TURN OFF the stov e, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stov e. Wait until smoke inside the firebox clears ...

  • Osburn HYBRID-45 MF - page 16

    FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that holes have not become plugged. If so, clean thoroughly. ASH REMOVAL Ashes should be placed in a metal c ontainer with a tight-fitting lid. The closed container or as hes should ...

  • Osburn HYBRID-45 MF - page 17

    VACCUM USE If a vacuum is used to clean y our stove, we suggest using a vacuum designed for ashes. Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage. CLEANING a. Heat Exchange Tubes – Your Osburn Hybrid-45 MF stove is designed with a built-in hea ...

  • Osburn HYBRID-45 MF - page 18

    CHIMNEY CLEANING a. Creoso te Formation – When an y wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapo rs condense in the r ela tively cool chimney flue or a n ewly started fire or from a s low- burning fire. As a result, creosote residue accumulates on the flu ...

  • Osburn HYBRID-45 MF - page 19

    When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money b y enablin g you to solve simple problems yourself. Problems can be c aused by to only five factors: 1) poor fuel; 2) poor operat ion or maintenance; 3) po or installation; 4) component failure; 5) factory defect. You can us ually s ...

  • Osburn HYBRID-45 MF - page 20

    STOVE SHUTS OFF AND APPEA RS ON THE CO NTROL BOA RD Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The hopper is out of pellets. Refill the hopper. 2. The air damper is too far open f or a low feed setting. If burning on the low setting, you may need to close the damper all the way blowers have sleeve bearings that are pe ...

  • Osburn HYBRID-45 MF - page 21

    STOVE FEEDS PELLETS, BUT W ILL NOT IGNITE AND APPEARS ON THE CONTROL BOARD Possible Causes: Possible Remedies: 1. Air damper open too far for ignition. Turn the air supply knob toward the minimum setting for startup. In some situations, it may be necessary to have the damper completely closed for ignition to take place. After there is a flame, the ...

  • Osburn HYBRID-45 MF - page 22

    STOVE STOPS FEEDING PELLETS AND APPEARS ON THE CONTROL BO ARD Possible Causes: Possible Remedies: 1. The L-250 automatic high temperature switch has tripped. The L-250 automatic high temperature switch is located on the auger housing and will send a signal to the control board if the auger housing overheats. Wait until the stove cools down. YOU NEE ...

  • Osburn HYBRID-45 MF - page 23

    • GL AS S “ S O OT ’ S ” UP AT A V E R Y F AS T R AT E • FLAME IS LAZY, DARK, AND HAS BL ACK TIPS • AFTER STOVE HA S BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Possible Remedies: 1. Stove or vent pipe is dirty, which restricts airflow through the burn pot. Follow all cleaning procedure in the maintenance section of the ...

  • Osburn HYBRID-45 MF - page 24

    ALARM CODES CHART MESSAGE CORRESPONDING ERROR Pressure switch error. L-250 automatic high temperature switch, located under the auger. L-250 manual reset high temperature s wit ch, located beside convection blower. Hopper is empty Lighting error. Hopper lid stay open more than 3 minutes. Inverted polarity in power outlet. Power outage Igniter fuse ...

  • Osburn HYBRID-45 MF - page 25

    L2(LINE COMMON) L1(LINE HOT) L1(LINE NO CONNECTED) FRAME GROUND L-250 RESET N.C. F-140 N.O. AIR FLOW PRESSURE SWITCH N.O. L-250 N.C. F-160 N.O. ELECTRONIC BOARD IGNITER AUGER MOTOR COMBUSTION/EXHAUS T BLOWER HOPPER LID SWITCH N.O. THERMOSTAT TERMINALS N.O. CONVECTION BLOWER CONVECTION BLOWER AIR SUPPLY KNOB HIGH TEMPERA TURE SWITCH F- 160 HIGH TEMP ...

  • Osburn HYBRID-45 MF - page 26

    Contact an Authorized OSBURN D ealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. ITEM PART # Airflow Pressure Switch 44029 Air Switch Hose 49004 Auger Motor 44038 Burn Pot PL52545 Control Board 44032 Combustion/Exhaust Blower Assembly 44039 Convection Blo ...

  • Osburn HYBRID-45 MF - page 27

    1700, rue Léon-Harmel, Québec (Québec) G 1N 4R9 tel. : (418) 527- 3060 fax : (418) 527-4311 e-mail : tech@sbi-international.com w eb site : www .osburn-mfg.com LIMITED LIFETIME WARRANTY The Osburn warranty extends only to the original consum er purchaser and is no t transferable. This warranty covers brand new pro ducts only, which have not been ...

Fabricante Osburn Categoría Electric Heater

Los documentos del dispositivo Osburn HYBRID-45 MF que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Osburn
- manuales de instrucciones HYBRID-45 MF
- hojas de producto Osburn
- folletos informativos
- o etiquetas energéticas Osburn HYBRID-45 MF
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Osburn HYBRID-45 MF.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Osburn HYBRID-45 MF, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Osburn HYBRID-45 MF. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Osburn HYBRID-45 MF.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Osburn HYBRID-45 MF, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Osburn HYBRID-45 MF. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Osburn HYBRID-45 MF.

El manual de instrucciones completo de Osburn debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Osburn HYBRID-45 MF - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Osburn HYBRID-45 MF, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Osburn HYBRID-45 MF que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Osburn HYBRID-45 MF - que deben facilitarnos los primeros pasos durante el uso de Osburn HYBRID-45 MF
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Osburn HYBRID-45 MF
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Osburn HYBRID-45 MF en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Osburn HYBRID-45 MF?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Osburn HYBRID-45 MF, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Osburn HYBRID-45 MF probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen