Manual de instrucciones Lincoln Electric INVERTEC V160-S

29 de páginas 0.61 mb
Descargar

Pasar a la página of 29

Summary
  • Lincoln Electric INVERTEC V160-S - page 1

    INVER TEC V160-S ™ OPERA TOR’S MANUAL IM737-A August, 2007 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed a nd built with s afety in mind. Ho wever , y our ov erall safety can be increased by pr oper installatio n ... and thought- ful opera tion o n your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WIT ...

  • Lincoln Electric INVERTEC V160-S - page 2

    FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. _______________________________________________ ...

  • Lincoln Electric INVERTEC V160-S - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b. Use suitable clothing made from durable flame-resistant material to protect your ski ...

  • Lincoln Electric INVERTEC V160-S - page 4

    iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8 .b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ʼs recommendations. 8.c. Ground the equipment in accordance with the U.S. Nat ...

  • Lincoln Electric INVERTEC V160-S - page 5

    iv SAFETY iv Mar . ʻ93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ʼArc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric INVERTEC V160-S - page 6

    v v Thank You for selecting a QUALITY product. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructi ...

  • Lincoln Electric INVERTEC V160-S - page 7

    vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A T echnical Specifications ....................................................................................................... A-1 Safety Precautions......................... ...

  • Lincoln Electric INVERTEC V160-S - page 8

    A-1 INST ALLA TION V160-S A-1 Input Circuit 1 15V (20A Plug and Branch) 1 15V (30A Branch) 230V (30A Branch) 230V (30A Branch) Maximum Open Circuit V oltage 48 V olts Max. Duty Cycle 100% 35% 100% Output Current Range 5-160 Amps INPUT - SINGLE PHASE ONL Y RA TED OUTPUT OUTPUT Height Widt h Depth Weight 12.6 in. 7.9 in. 16.9 in. Approx. 24.2lbs. 320 ...

  • Lincoln Electric INVERTEC V160-S - page 9

    A-2 INST ALLA TION V160-S A-2 Read entire installation section before starting installation. SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should per- form this installation. • Disconnect input power by removing plug from receptacle before working inside V160-S. Allow machine to sit for 5 minutes minimum to allow the po ...

  • Lincoln Electric INVERTEC V160-S - page 10

    A-3 INST ALLA TION V160-S A-3 Fuse the input circuit with time delay fuses marked “D” or delay type 1 circuit breakers. Using fuses or circuit breakers smaller than recommended may result in “nuisance” shut-offs from welder inrush currents even if not welding at high currents. 1 Also called “inverse time” or “thermal/magnetic” circu ...

  • Lincoln Electric INVERTEC V160-S - page 11

    A-4 INST ALLA TION V160-S A-4 OUTPUT CONNECTIONS ELECTRIC SHOCK can kill. • Keep the electrode holder and cable insulation in good condition. • Do not touch electrically live parts or electrode with skin or wet cloth- ing. • Insulate yourself from work and gr ound. • T urn the input line Switch on the Invertec V160- S “off” befor e conn ...

  • Lincoln Electric INVERTEC V160-S - page 12

    A-5 INST ALLA TION V160-S A-5 QUICK DISCONNECT PLUG (FOR STICK ELEC- TRODE CABLE) A quick disconnect system is used for the welding cable connections. The stick electrode cable will need to have a plug attached. 1. Cut off welding cable lug, if present. 2. Remove .75 in. (19mm) of welding cable insulation. 3. Slide rubber boot onto cable end. The b ...

  • Lincoln Electric INVERTEC V160-S - page 13

    B-1 OPERA TION V160-S B-1 Read and understand this entire section before operating your machine. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts such as output terminals or internal wiring. • Insulate yourself from the work and ground. • Always wear dry insulating gloves. ___________________________________ ...

  • Lincoln Electric INVERTEC V160-S - page 14

    B-2 OPERA TION B-2 REAR CONTROL P ANEL 1 . Power Switch: Controls the input power to the machine. Make sure the machine is properly con- nected to the input supply before turning the machine on.(See Figure B.1) 2. F a n : The cooling fan will turn ON when the machine is turned ON and it will continue to run whenever the output of the machine is ON. ...

  • Lincoln Electric INVERTEC V160-S - page 15

    B-3 OPERA TION B-3 7. Remote LED: This indicator will turn on when a remote control is connected to the machine via the remote control connector . Using a remote control will change the function of the output current con- trol, refer to the output current control section below . 8. Output LED: This indicator turns on when the out- put of the machin ...

  • Lincoln Electric INVERTEC V160-S - page 16

    B-4 OPERA TION B-4 V160-S DIP SWITCH FUNCTIONS T his section has 8 DIP switch functions of the V160- S. Read and understand the functions before making any changes because abnormal operation can occur with the wrong settings. The machine must be turned OFF when the DIP Switches are changed. ELECTRIC SHOCK CAN KILL: Be sure that all installation, op ...

  • Lincoln Electric INVERTEC V160-S - page 17

    B-5 OPERA TION B-5 DIP Switch 6: European/USA Machine Configuration This configures several functions of the V160-S as required by the European and USA markets. For the European market it is OFF and for the USA market it is ON. Specifically , this configures the operation of the TIG slope timers, remote control, and trigger . However , this configu ...

  • Lincoln Electric INVERTEC V160-S - page 18

    C-1 ACCESSORIES C-1 OPTIONAL ACCESSORIES AND COMP A TIBLE EQUIPMENT Factory Installed Electrical Holder and Cable Assembly Work Cable and Clamp Strap Packet Instruction Manual Field Installed K870 - Foot Amptrol tm for TIG welding. When the V160-Sʼs Output Control is in the “REMOTE” position, the foot Amptrol energizes the output and controls ...

  • Lincoln Electric INVERTEC V160-S - page 19

    D-1 MAINTENANCE D-1 V160-S SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Have an electrician install and serv- ice this equipment. • T urn the input power off at the fuse box, disconnect supply lines and allow machine to sit for five minutes minimum to allow the power capaci- tors to discharge before working inside this equipment. • Do not to ...

  • Lincoln Electric INVERTEC V160-S - page 20

    E-1 TROUBLESHOOTING E-1 V160-S If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This T roubleshooting Guide is provided to help you locate and repair possibl ...

  • Lincoln Electric INVERTEC V160-S - page 21

    E-2 TROUBLESHOOTING E-2 V160-S Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENTS(S) RECOMMENDED COURSE OF ACTION Excessive spatter Craters Inclusions Insufficient penetration Sticking Porosity Cracks 1. Long arc 2. High current 1 . Fast movement of the electrode away from piece. 1. Po ...

  • Lincoln Electric INVERTEC V160-S - page 22

    E-3 TROUBLESHOOTING E-3 V160-S If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POS ...

  • Lincoln Electric INVERTEC V160-S - page 23

    E-4 TROUBLESHOOTING E-4 V160-S Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION Machine fails to come on (Power LED off) Power Input incorrect Input over-current (Power LED Flashing) No output current (Power LED on) (Output LED off) Thermal overload (Th ...

  • Lincoln Electric INVERTEC V160-S - page 24

    F-1 DIAGRAMS F-1 V160-S NOTE: This diagram is for refer ence only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a r eplacement. Give the equipment code number . ...

  • Lincoln Electric INVERTEC V160-S - page 25

    F-2 DIAGRAMS F-2 V160-S NOTE: This diagram is for refer ence only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a r eplacement. Give the equipment code number . ...

  • Lincoln Electric INVERTEC V160-S - page 26

    NOTES V160-S ...

  • Lincoln Electric INVERTEC V160-S - page 27

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA E ...

  • Lincoln Electric INVERTEC V160-S - page 28

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes ...

  • Lincoln Electric INVERTEC V160-S - page 29

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .lincolnelectric.com • World's Leader in W elding and Cutting Products • ...

Fabricante Lincoln Electric Categoría Welder

Los documentos del dispositivo Lincoln Electric INVERTEC V160-S que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lincoln Electric
- manuales de instrucciones INVERTEC V160-S
- hojas de producto Lincoln Electric
- folletos informativos
- o etiquetas energéticas Lincoln Electric INVERTEC V160-S
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lincoln Electric INVERTEC V160-S.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lincoln Electric INVERTEC V160-S, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lincoln Electric INVERTEC V160-S. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lincoln Electric INVERTEC V160-S.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lincoln Electric INVERTEC V160-S, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lincoln Electric INVERTEC V160-S. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lincoln Electric INVERTEC V160-S.

El manual de instrucciones completo de Lincoln Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lincoln Electric INVERTEC V160-S - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lincoln Electric INVERTEC V160-S, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lincoln Electric INVERTEC V160-S que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lincoln Electric INVERTEC V160-S - que deben facilitarnos los primeros pasos durante el uso de Lincoln Electric INVERTEC V160-S
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lincoln Electric INVERTEC V160-S
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lincoln Electric INVERTEC V160-S en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lincoln Electric INVERTEC V160-S?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lincoln Electric INVERTEC V160-S, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lincoln Electric INVERTEC V160-S probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)