Graco 1095 Premium Hi - page 1
3A0156A Operation Electric Airless Spra yer s - For P ortable Airless Spraying of Ar chitectural Coatings and P aints - 3300 psi (227 bar , 22.7 MP a) Maximum W orking Pressure IMPORT ANT SAFETY INSTRUCTIONS Read all w ar nings and instr uctions in this manual. Sav e thes e instructio ns. Related Man uals: Repair 3A015 7 P arts 3A0158 Gun 311861 69 ...
-
Graco 1095 Premium Hi - page 2
Models: 2 3A0156A Models: 695 UL TRA MAX lIl Model QuikReel Hi-Bo y Lo-Bo y 258719 ✓✓ 258720 ✓ 258722 ✓ 258872 ✓ 258873 ✓ 258874 ✓ 258876 ✓ 258877 ✓✓ 826124 ✓✓ 826125 ✓ 826127 ✓ 795 UL TRA MAX III Model QuikReel Hi-Bo y Lo-Bo y 258723 ✓✓ 258724 ✓ 258878 ✓✓ 258879 ✓ 258881 ✓ 258882 ✓✓ 826128 ✓✓ 82612 ...
-
Graco 1095 Premium Hi - page 3
Warnings 3A0156A 3 W arnings The f ollowing warnings are f or the setup , use, g rounding, maintenance and repair of this equipment. The e xclamation point symbol aler ts y ou to a general wa r ning and the hazard symbol ref ers to procedure-specific risks. Ref e r bac k to these warnings. Addit ional, product-specific w ar nings ma y be f ound thr ...
-
Graco 1095 Premium Hi - page 4
Warnings 4 3A0156A FIRE AND EXPLOSION HAZARD Flammable fumes , such as solvent and p aint fumes, in work area can ignite or e xplode. T o help pre vent fire and e xplosion: • Do not spra y flammabl e or combustible materials near an open flame or sources of ignition such as cig- arettes, motors , and electrical equipment. • P aint or solvent fl ...
-
Graco 1095 Premium Hi - page 5
Warnings 3A0156A 5 W ARNING EQUIPMENT MISU SE HAZARD Misuse can cause death or serious injur y . • Alwa ys wear appropriate glov es, eye protection, and a respir ator or mask when painting. • Do not operate or spra y near children. K eep children aw a y from equipment at all times. • Do not ov erreach or stand on an unstable support. Keep eff ...
-
Graco 1095 Premium Hi - page 6
Component Identification 6 3A0156A Component Identification 11. 12. 10. 13. 1. 2. 4. 5. 6. 7. 8. 9. 3. ti14839a 1 Premium Digital Display 2 ON/OFF Switch 3 W atchDog ™ Switch (not av ailable on Mar k V or Standard Units) 4 Pressure Control 5 Prime / Spra y V alve 6 Filter 7 Siphon T ube 8P u m p 9 Bearing Housing / ProConne ct ™ 10 Drain T u be ...
-
Graco 1095 Premium Hi - page 7
Grounding 3A0156A 7 Gr ounding The spra yer must be g rounded. Grounding reduces the risk of static and electric shoc k by pro viding an escape wire f or the electrical current due to static bu ild up or in the e v ent of a shor t circuit. The spra yer cord includes a gro unding wire with an appropriate gro unding contact. The plug must be plugged ...
-
Graco 1095 Premium Hi - page 8
15/20 Amp Switch (Not Available on All Units) 8 3A0156A 15/20 Amp Switch (Not A vailable on All Unit s) Select 15A or 20A setting based on your circuit rating. Pressure Relief Pr ocedure 1. T ur n power OFF . Wait 7 seconds f or power to dissipate. 2. Lock gun trigger sa f ety . Remove guard and SwitchTip . 3. T urn pressure to lowest setting. T ri ...
-
Graco 1095 Premium Hi - page 9
Setup 3A0156A 9 Setup 1. Standard Units Only : Connect Graco airless hose to spra yer . Tighten secure ly . 2. Standard Units Only : Connect other end of hose to gun and tighten securely . 3. Engage gun t rigger s af ety . 4. Remo ve t ip guard. 5. Check inlet strainer f or clogs and de bris. 6. Fill throat pac king nut with Graco TSL to pre v ent ...
-
Graco 1095 Premium Hi - page 10
Startup 10 3A0156A Star tup 1. T ur n pressure control to lowest pressure. 2. T ur n power ON . 3. Increase pressur e 1/2 tur n to star t motor and allo w fluid to circulat e through drain tu be for 15 seconds; turn pressure do wn. 4. T urn pr ime v alve forw ard to SPRA Y position. Disen- gage gun tr igger safety . 5. Hold gun against ground ed me ...
-
Graco 1095 Premium Hi - page 11
Switch Tip Installation 3A0156A 11 Switch Tip Installation 1. Use spray tip (A) to inser t OneSe al ™ (B) into guard (C). 2. Inser t Switch Tip . 3. Scre w assemb ly onto gun. Tighten. Spra y 1. Spra y test patter n. Increa se pressure to eliminate heavy ed ges. Use smaller tip siz e if pressure adjust- ment can not eliminate hea vy edges. 2. Hol ...
-
Graco 1095 Premium Hi - page 12
WatchDog ™ Protection System (Not Available on All Uni ts) 12 3A0156A W atchDog ™ Pr otection System (Not A vailab le on All Units) Pump stops automatically when m aterial pa il is empty . To A c t i v a t e : 1. P er f or m Startup . 2. Premium units with digi tal display: T ur n W atchDog swit ch ON and WD ON displa ys. EMPTY displa ys/flashe ...
-
Graco 1095 Premium Hi - page 13
Hose Reel (Not Available on All Units) 3A0156A 13 Hose Reel (Not A vailab le on All Units) 1. Mak e sure hose is routed throug h hose guide. 2. Lift and tur n piv ot lock 90° to unlock hose reel. Pull on hose to remo ve it from hose reel. 3. Pull reel hand le up and tur n cloc kwise to reel in hose . NO TE: The hose re el can be locked into two po ...
-
Graco 1095 Premium Hi - page 14
Digital Tracking System (Not Available on All Uni ts) 14 3A0156A Digital T rac king System (Not A vailab le on All Units) Operation Main Menu Shor t press to mo ve to next d isplay . Press and hold (5 seconds) to chang e units or reset data. 1. T ur n pressu re to lowest setting. T rigge r gun to relie ve pressure. T ur n prime valve do wn to DRAIN ...
-
Graco 1095 Premium Hi - page 15
Digital Tracking System (Not Available on All Units) 3A0156A 15 Secondary Menu - Stored Data and W atchDog Pump Protection Modes 1. P er f or m Pressure Relief, steps 1 - 4 if they hav e not already been do ne. 2. T ur n pow er switch on while holding DTS button down. 3. SERIAL NUMBER scrolls past and then serial num- ber (e .g. 00001) displa ys. 4 ...
-
Graco 1095 Premium Hi - page 16
Cleanup 16 3A0156A Cleanup 1. P er f or m Pressure Relief Procedure (page 8), steps 1 - 4. Remo ve siphon tube set from paint and place in flushing flui d. Remov e tip guard from gun. NO TE : U se wa ter for wat er- bas e paint, mineral spir its f or oil-base paint, or othe r solvents reco mmended by manuf acturer . 2. T ur n power ON . T urn prime ...
-
Graco 1095 Premium Hi - page 17
Cleanup 3A0156A 17 9. Remov e filters from gun an d spra yer , if installed. Clean and inspect. Install filters. 10. If flushing with water , flush again with mineral spirits, or Pump Ar mor , to leav e a protective coating to pre- vent freezing or corrosion. 11. Wipe spra yer , hose and gun with a rag soak ed in water or miner al spir its. ti15018 ...
-
Graco 1095 Premium Hi - page 18
Technica l Data 18 3A0156A Te c h n i c a l D a t a Basic Sprayer Wetted Parts......... ..................... zinc- and nick el-plated carbon steel, nylon, stainl ess steel, PTFE, Acetel, leather , UHMWPE, aluminum tungsten carbide, PEEK, brass Noise Level Sound powe r .................... .................... .......91 dBa* Sound pressure ........ ...
-
Graco 1095 Premium Hi - page 19
Notes 3A0156A 19 Notes ...
-
Graco 1095 Premium Hi - page 20
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 3A0156 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 14 ...
¿Tienes una pregunta acerca de Graco 1095 Premium Hi?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Graco 1095 Premium Hi, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Graco 1095 Premium Hi probablemente compartirá una forma de solucionarlo.