Manual de instrucciones Fairchild RC4194

15 de páginas 0.11 mb
Descargar

Pasar a la página of 15

Summary
  • Fairchild RC4194 - page 1

    www .fairc hildsemi.com Features • Simultaneously adjustable outputs with one resistor to ± 42V • Load current – ± 200 mA with 0.04% load regulation Description The RC/RM4194 are dual polarity tracking regulators designed to provide balanced or unbalanced positi ve and negati ve output v oltages at currents to 200 mA. A single external resi ...

  • Fairchild RC4194 - page 2

    PRODUCT SPECIFICATION RC4194 2 Absolute Maxim um Ratings (bey ond which the device ma y be damaged) 1 Note: 1. Functional operation under any of these conditions is NOT implied. P arameter Min T yp Max Units Supply Voltage RC4194 ± 35 V RM4194 ± 45 V Supply Input to Output Voltage Differential RC4194 ± 35 V RM4194 ± 45 V Load Current PDIP 100 m ...

  • Fairchild RC4194 - page 3

    RC4194 PRODUCT SPECIFICATION 3 Operating Conditions Electrical Characteristics ( ± 5 £ V OUT £ V MAX ; – V IN £ -8V ; I L = ± 1mA; RM4194: -55 ° C £ T j £ +125 ° C; RC4194: 0 ° C £ T j £ +70 ° C unless otherwise specified) Notes: 1. Measured as (mA) 2. Output voltage temperature drift guaranteed by design. 3. The current drain will ...

  • Fairchild RC4194 - page 4

    PRODUCT SPECIFICATION RC4194 4 T ypical Perf ormance Characteristics Figure 1. Ripple Rejection vs. Frequency Figure 2. Load Regulation vs. Load Current Figure 3. Output Voltage Tracking vs. Temperature 65-0201 Ripple Rejection (dB) F (Hz) 150 130 110 90 70 50 30 10 0 100 1K 10K 100K V OUT = ± 15V 65-0202 T j = +125 ¡ C T j = +25 ¡ C 0.06 0.05 0 ...

  • Fairchild RC4194 - page 5

    RC4194 PRODUCT SPECIFICATION 5 T ypical Applications Figure 4. Unbalanced Output Voltage — Comparator Application Figure 5. High Output Application 0.01 µ F S -V S +V S +V -V S 71.5K 0.01 µ F R SET Comp- Gnd RM4194 Comp+ R -V Bal +V OUT OUT 0 0 R A R B R 4.7 µ F 4805 4.7 µ F** +V OUT To Additional Comparators (Typically 15 RC4805s) -V = -5V T ...

  • Fairchild RC4194 - page 6

    PRODUCT SPECIFICATION RC4194 6 T ypical Applications (continued) Figure 6. Balanced Output Voltage — Op Amp Application Figure 7. Digitally Controlled Dual 200 mA Voltage Regulator 0.001 µ F S -V S +V S +V -V S 71.5K 0.001 µ F R SET Comp- Gnd 4194 Comp+ R -V +V OUT OUT 0 0 R 4.7 µ F 741 4.7 µ F** +V = +15V OUT To Additional Op Amps (Typically ...

  • Fairchild RC4194 - page 7

    RC4194 PRODUCT SPECIFICATION 7 RC4194 Switchab le P ower Suppl y The outputs of the RC4194 can be simultaneously switched on or off under logic control as sho wn in Figure 8. In the “off” state, the outputs will be forced to a minimum v oltage, or about ± 20 mV , rather than becoming open-circuit. The turn-on time, with the outputs programmed ...

  • Fairchild RC4194 - page 8

    PRODUCT SPECIFICATION RC4194 8 Figure 9. RC4194 Recommended Compensation 4194 0.001 µ F Comp+ R 0 Comp- R 0 R SET R SET 0.01 µ F 0.01 µ F 0.001 µ F 4.7 µ F * 65-4201 +V S –V S +V S –V S +V OUT –V OUT +V OUT –V OUT Note: All Capacitors are Ceramic Disc Except * = Solid Tantalum All compensation and bypass caps should hav e short leads, ...

  • Fairchild RC4194 - page 9

    RC4194 PRODUCT SPECIFICATION 9 If a small signal silicon diode is used, it will clamp the nega- tiv e output voltage at about +0.55V . A Schottky barrier or germanium device w ould clamp the voltage at about +0.3V . Another cure which will keep the negati ve output negati ve at all times is the 1 m W resistor connected between the +15V output and t ...

  • Fairchild RC4194 - page 10

    PRODUCT SPECIFICATION RC4194 10 T able 1. Commercial Heatsink Selection Guide No attempt has been made to provide a complete list of all heatsink manuf acturers. This list is only representative . Staver Co., Inc.: 41-51 N Saxon Ave., Bay Shore, NY 11706 IERC: 135 W Magnolia Blvd., Burbank, CA 91502 Thermalloy: P.O. Box 34829, 2021 W Valley View Ln ...

  • Fairchild RC4194 - page 11

    RC4194 PRODUCT SPECIFICATION 11 Simplified Schematic Dia gram 65-0198 Q28 Q30 Q29 Q33 Q34 Q37 Q36 Q35 Q38 Comp+ (7) R18 10K R4 500 R5 25K Q47 Q16 Q13 Q11 Q10 Q9 Q12 C1 10 pF R6 30K Q8 Q2 Q4 Q3 Q1 R1 12K Q6 R2 680 R3 5000 R7 5000 Q5 Q7 (3) R (2) R R11 3900 R10 1650 Q19 Q22 Q23 Q24 Q17 Q21 Q20 Q44 R8 5000 Q31 Q25 Q26 8 k W 200 W R14 3000 W Q46 Q18 Q ...

  • Fairchild RC4194 - page 12

    PRODUCT SPECIFICATION RC4194 12 Mechanical Dimensions 9-Lead Metal Can IC Header P ackage S r2 øb øp F øD1 øD A q r1 e e1 Notes: 1. All leads—increase maximum limit by .003 (.08mm) when lead finish is applied. A .250 .340 6.35 8.64 Symbol Inches Min. Max. Min. Max. Millimeters Notes øb .028 .034 .71 .86 øD — .620 — 15.75 øD1 .470 .500 ...

  • Fairchild RC4194 - page 13

    RC4194 PRODUCT SPECIFICATION 13 Mechanical Dimensions (contin ued) 14-Lead Ceramic DIP P ackage A — .200 — 5.08 Symbol Inches Min. Max. Min. Max. Millimeters Notes b1 .014 .023 .36 .58 .065 1.65 b2 .045 1.14 c1 .008 .015 .20 .38 E .220 .310 5.59 7.87 e .100 BSC 2.54 BSC L .125 .200 3.18 5.08 .015 .060 .38 1.52 .005 — .13 — 3 6 8 4 8 2 4 5, ...

  • Fairchild RC4194 - page 14

    PRODUCT SPECIFICATION RC4194 14 Mechanical Dimensions (contin ued) 14-Lead Plastic DIP P ackage D B1 e B E1 A1 A L 7 8 14 1 E eB C D1 A — .210 — 5.33 Symbol Inches Min. Max. Min. Max. Millimeters Notes A1 .015 — .38 — .022 .56 B .014 .36 .195 4.95 A2 .115 2.93 B1 .045 .070 1.14 1.78 D .725 .795 18.42 20.19 .300 .325 7.62 8.26 E eB — .430 ...

  • Fairchild RC4194 - page 15

    PRODUCT SPECIFICATION RC4194 5/20/98 0.0m 001 Stock#DS30004194 Ó 1998 Fairchild Semiconductor Corporation LIFE SUPPORT POLICY FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1 . L ...

Fabricante Fairchild Categoría Thermostat

Los documentos del dispositivo Fairchild RC4194 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Fairchild
- manuales de instrucciones RC4194
- hojas de producto Fairchild
- folletos informativos
- o etiquetas energéticas Fairchild RC4194
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Fairchild RC4194.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Fairchild RC4194, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Fairchild RC4194. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Fairchild RC4194.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Fairchild RC4194, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Fairchild RC4194. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Fairchild RC4194.

El manual de instrucciones completo de Fairchild debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Fairchild RC4194 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Fairchild RC4194, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Fairchild RC4194 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Fairchild RC4194 - que deben facilitarnos los primeros pasos durante el uso de Fairchild RC4194
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Fairchild RC4194
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Fairchild RC4194 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Fairchild RC4194?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Fairchild RC4194, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Fairchild RC4194 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)