Manual de instrucciones Procom AL500HYLA

14 de páginas 1.07 mb
Descargar

Pasar a la página of 14

Summary
  • Procom AL500HYLA - page 1

    OUTDOOR GAS FIREPLACE IMPORTANT: Read this owner's manual carefully and completely before trying to assemble, operate, or service this heater . FOR YOUR SAFETY : Do not store or use gasoline or other flammable vapors and liquids in the vici nity of this or any other appliance. WHA T T O DO IF YOU SMELL GAS:  Do not try to light any applianc ...

  • Procom AL500HYLA - page 2

    2 AL058-01 SAFETY INFORMA TION PRODUCT IDENTIFICA TION 1. Check the heater completely and thoroughly fo r damage. DO NOT run a damaged heater . 2. DO NOT alter the heater or operate a heater that has been modified from its original condition. 3. Use only propane gas. 4. Use only vapor with drawal prop ane gas. If any question, contact your LP deale ...

  • Procom AL500HYLA - page 3

    3 AL058-01 INST ALLA TION TOOLS REQUIRED: ● Philips screwdriver ● Wrench Check if you have the items listed below before installation. ● Logs: 10 ● 4 × 14 self-tapping screw: 5 ● M4 × 10 screw: 32 ● M5 × 1 0 s c r e w : 4 ● C o l u m n : 4 ● Log grate: 1 ● Fixing hoop: 1 ● Hex head screw: 2 ● Handle: 1 ● Screen: 4 Caution ...

  • Procom AL500HYLA - page 4

    4 AL058-01 7. Attach the four columns to the burne r plate with M4 × 10 screws provided. Do not tighten at this time. (See FIG .7) INST ALLA TION INSTRUCTIONS Continued Fi g ure 7 -Column installation 5. Install log s 1,2,3,4,5 by inserting each log screw into holes of corresponding grate branch . Make sure e ach log is placed in proper sequence.( ...

  • Procom AL500HYLA - page 5

    5 AL058-01 8. Set the top p anel in place on the columns and secure with M4 × 10 screws provided. Do not tighten at this time. (See FIG .8) 12. From the outer side, use M5 × 10 screws to fasten the fixing hoop on the right and left support. Fasten the other side of the fixing hoop af ter the cylinder is in place. (See FIG .1 1) Note: The installe ...

  • Procom AL500HYLA - page 6

    6 AL058-01 CONNECTING TO GAS SUPPL Y C o n t i n u e d FUEL REQUIREMENTS:  Connect reg ulator/hose with sta ndard 20-pound LP cylinder coupler .  Call the LP gas supplier to inspe ct the cylinder . Do not use a damaged LP gas cylinder .  Do not use LP gas without proper decompression.  Do not connect irregul ar LP gas supply with heater ...

  • Procom AL500HYLA - page 7

    7 AL058-01 11. S piders and insects can nest a nd live in outd oor appliances, especially in the bu rners and orifice s. This will interrupt the normal flow of LP gas to the heater and can be a very dangerous situation. Inspect for insect infiltration of burner/orifice when one of the following occurs: A. The smell of gas along with predomin ating ...

  • Procom AL500HYLA - page 8

    8 AL058-01 PARTS NOT UNDER WARRANTY: Contact authorized dealers of this product or Parts Central if they can't supply original replacement part(s) Call P RO-COM's Parts Department at 1-877-886-5989 for referral information. When calling PRO-COM, have ready  Model number of your heater  The replacement part number ACCESSORIES Purchas ...

  • Procom AL500HYLA - page 9

    9 AL058-01 PARTS LIST HP500MA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 AB01001 Top Panel 1 2 AB29001 Mesh Screen 2 3 AB29002 Mesh Screen 2 4 AL002-01 Column 6 5 AL009-01 Burner Fixing Plate 6 ...

  • Procom AL500HYLA - page 10

    10 AL058-01 ILLUSTRATED PARTS BREAKDOWN AL500HYLA ...

  • Procom AL500HYLA - page 11

    11 AL058-01 PARTS LIST HP500MA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 NBY50-200A1 Burner 1 2 NDW-L600×4 Safety Pilot 1 3 AB31002 Safety Pilot Inlet Tube ASM 1 4 NV2020-1217 Control Valve 1 ...

  • Procom AL500HYLA - page 12

    12 AL058-01 ILLUSTRATED PARTS BREAKDOWN AL500HYLA ...

  • Procom AL500HYLA - page 13

    13 AL058-01 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. LOGS LIST AL500HYLA KEY NO. PART NUMBER DESCRIPTION QTY. 1 AL057-01 Log 1 1 2 AL057-02 Log 2 1 3 AL057-03 Log 3 1 4 AL057-04 Log 4 1 5 AL057-05 Log 5 1 6 AL057-06 Log 6 1 7 AL057 ...

  • Procom AL500HYLA - page 14

    1 4 AL058-01 LOGS LIST AL500HYLA NANJING PRO-COM ELECTR IC APPLIANCE CO.,LTD. #6 CHUANGYE ROAD, HIGH NEW TECH. ZONE, NANJING, 210061, CHINA PRO-COM T o ll-F r ee number : 1-877-886-5989 ...

Fabricante Procom Categoría Outdoor Fireplace

Los documentos del dispositivo Procom AL500HYLA que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Procom
- manuales de instrucciones AL500HYLA
- hojas de producto Procom
- folletos informativos
- o etiquetas energéticas Procom AL500HYLA
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Procom AL500HYLA.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Procom AL500HYLA, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Procom AL500HYLA. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Procom AL500HYLA.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Procom AL500HYLA, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Procom AL500HYLA. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Procom AL500HYLA.

El manual de instrucciones completo de Procom debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Procom AL500HYLA - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Procom AL500HYLA, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Procom AL500HYLA que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Procom AL500HYLA - que deben facilitarnos los primeros pasos durante el uso de Procom AL500HYLA
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Procom AL500HYLA
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Procom AL500HYLA en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Procom AL500HYLA?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Procom AL500HYLA, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Procom AL500HYLA probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)